{"title":"高压液相色谱法测定血浆中环孢素A的含量。","authors":"M C Allwood, R Lawrance","doi":"10.1111/j.1365-2710.1981.tb00992.x","DOIUrl":null,"url":null,"abstract":"<p><p>A sensitive and rapid high performance liquid chromatographic method was developed for the determination of Cyclosporin A in plasma. Cyclosporin A was isolated from methanol-precipitated plasma using miniature compressed silica reverse-phase columns (Sep-Paks). In the method, 1 ml serum is precipitated in 3 ml methanol. After centrifugation 2 ml of supernatant is diluted in 1 ml water and the sample flushed through a washed Sep-Pak. The sample on the miniature column is washed with water and 75% v/v methanol, and Cyclosporin A is eluted in 1 ml methanol. At least 80% of the drug is recovered. Samples are analyzed on a reverse-phase column, the mobile phase is methanol:water (95:5) and detection is conducted at 205 nm. The detection limits were less than 100 ng/ml, but in plasma some interference was observed, especially at concentrations below 1000 ng/ml.</p>","PeriodicalId":77862,"journal":{"name":"Journal of clinical and hospital pharmacy","volume":"6 3","pages":"195-9"},"PeriodicalIF":0.0000,"publicationDate":"1981-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1111/j.1365-2710.1981.tb00992.x","citationCount":"10","resultStr":"{\"title\":\"High pressure liquid chromatographic determination of cyclosporin A in plasma.\",\"authors\":\"M C Allwood, R Lawrance\",\"doi\":\"10.1111/j.1365-2710.1981.tb00992.x\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>A sensitive and rapid high performance liquid chromatographic method was developed for the determination of Cyclosporin A in plasma. Cyclosporin A was isolated from methanol-precipitated plasma using miniature compressed silica reverse-phase columns (Sep-Paks). In the method, 1 ml serum is precipitated in 3 ml methanol. After centrifugation 2 ml of supernatant is diluted in 1 ml water and the sample flushed through a washed Sep-Pak. The sample on the miniature column is washed with water and 75% v/v methanol, and Cyclosporin A is eluted in 1 ml methanol. At least 80% of the drug is recovered. Samples are analyzed on a reverse-phase column, the mobile phase is methanol:water (95:5) and detection is conducted at 205 nm. The detection limits were less than 100 ng/ml, but in plasma some interference was observed, especially at concentrations below 1000 ng/ml.</p>\",\"PeriodicalId\":77862,\"journal\":{\"name\":\"Journal of clinical and hospital pharmacy\",\"volume\":\"6 3\",\"pages\":\"195-9\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1981-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1111/j.1365-2710.1981.tb00992.x\",\"citationCount\":\"10\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of clinical and hospital pharmacy\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1111/j.1365-2710.1981.tb00992.x\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of clinical and hospital pharmacy","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1111/j.1365-2710.1981.tb00992.x","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
High pressure liquid chromatographic determination of cyclosporin A in plasma.
A sensitive and rapid high performance liquid chromatographic method was developed for the determination of Cyclosporin A in plasma. Cyclosporin A was isolated from methanol-precipitated plasma using miniature compressed silica reverse-phase columns (Sep-Paks). In the method, 1 ml serum is precipitated in 3 ml methanol. After centrifugation 2 ml of supernatant is diluted in 1 ml water and the sample flushed through a washed Sep-Pak. The sample on the miniature column is washed with water and 75% v/v methanol, and Cyclosporin A is eluted in 1 ml methanol. At least 80% of the drug is recovered. Samples are analyzed on a reverse-phase column, the mobile phase is methanol:water (95:5) and detection is conducted at 205 nm. The detection limits were less than 100 ng/ml, but in plasma some interference was observed, especially at concentrations below 1000 ng/ml.