{"title":"相关技术及其在His束心电图中的应用。","authors":"X S Wang","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>In literature, the HBE has been displayed by application of the averaging method. In this paper, correlation analysis technique was used and the body-surface HBE was displayed in a special-purpose electronic computer. The correlation coefficients of the P-A, A-H, H-V intervals and the H-wave width of both methods are almost equivalent and one can be substituted by the other. Compared with the averaging method, the S/N ratio of the correlation method is greater and the residual noise is nearly absent. Furthermore, the effects of the integrating time T and delay time delta tau on the S/N ratio, the measuring resolution and the analytical time have been studied. Correlation analysis technique is a method based on the cybernetic and information theory. With this technique, by using correlation function, the dependence (auto-correlation function) of the value at one instant upon that of the other during the same random process, or the interdependence between sets of data from 2 random processes can be described. Up to the present, there has been no report on the activities of the ventricular conductive system with the S/N ratio smaller than 1, detected on the body surface by correlation analysis technique[1 - 3]. However, using this technique, the author successfully detected the body surface HBE with a special-purpose mini-computer in 1977.</p>","PeriodicalId":21694,"journal":{"name":"Scientia Sinica","volume":"23 12","pages":"1599-607"},"PeriodicalIF":0.0000,"publicationDate":"1980-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Correlation technique and its application in the His bundle electrocardiogram.\",\"authors\":\"X S Wang\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>In literature, the HBE has been displayed by application of the averaging method. In this paper, correlation analysis technique was used and the body-surface HBE was displayed in a special-purpose electronic computer. The correlation coefficients of the P-A, A-H, H-V intervals and the H-wave width of both methods are almost equivalent and one can be substituted by the other. Compared with the averaging method, the S/N ratio of the correlation method is greater and the residual noise is nearly absent. Furthermore, the effects of the integrating time T and delay time delta tau on the S/N ratio, the measuring resolution and the analytical time have been studied. Correlation analysis technique is a method based on the cybernetic and information theory. With this technique, by using correlation function, the dependence (auto-correlation function) of the value at one instant upon that of the other during the same random process, or the interdependence between sets of data from 2 random processes can be described. Up to the present, there has been no report on the activities of the ventricular conductive system with the S/N ratio smaller than 1, detected on the body surface by correlation analysis technique[1 - 3]. However, using this technique, the author successfully detected the body surface HBE with a special-purpose mini-computer in 1977.</p>\",\"PeriodicalId\":21694,\"journal\":{\"name\":\"Scientia Sinica\",\"volume\":\"23 12\",\"pages\":\"1599-607\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1980-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Scientia Sinica\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Scientia Sinica","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

在文献中,利用平均法显示了HBE。本文采用相关分析技术,在专用电子计算机上对体表HBE进行了显示。两种方法的P-A、A-H、H-V区间和h波宽度的相关系数几乎相等,可以用另一种方法代替。与平均方法相比,相关方法的信噪比更高,残差几乎不存在。此外,还研究了积分时间T和延迟时间δ τ对信噪比、测量分辨率和分析时间的影响。相关分析技术是一种基于控制论和信息论的方法。利用相关函数,可以描述同一随机过程中某一时刻值对另一时刻值的依赖关系(自相关函数),或者两个随机过程的数据集之间的相互依赖关系。截至目前,尚未见相关分析技术在体表检测到信噪比小于1的心室传导系统活动的报道[1 - 3]。然而,利用这种技术,作者在1977年成功地用专用微型计算机检测了体表HBE。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Correlation technique and its application in the His bundle electrocardiogram.

In literature, the HBE has been displayed by application of the averaging method. In this paper, correlation analysis technique was used and the body-surface HBE was displayed in a special-purpose electronic computer. The correlation coefficients of the P-A, A-H, H-V intervals and the H-wave width of both methods are almost equivalent and one can be substituted by the other. Compared with the averaging method, the S/N ratio of the correlation method is greater and the residual noise is nearly absent. Furthermore, the effects of the integrating time T and delay time delta tau on the S/N ratio, the measuring resolution and the analytical time have been studied. Correlation analysis technique is a method based on the cybernetic and information theory. With this technique, by using correlation function, the dependence (auto-correlation function) of the value at one instant upon that of the other during the same random process, or the interdependence between sets of data from 2 random processes can be described. Up to the present, there has been no report on the activities of the ventricular conductive system with the S/N ratio smaller than 1, detected on the body surface by correlation analysis technique[1 - 3]. However, using this technique, the author successfully detected the body surface HBE with a special-purpose mini-computer in 1977.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信