{"title":"用于呼吸流量模拟控制的双向微型热敏电阻传感器。","authors":"A Sekey,&nbsp;C Seagrave","doi":"10.3109/10731198109117603","DOIUrl":null,"url":null,"abstract":"<p><p>A subminiature airflow sensor is described, which can discriminate between exhalation and inhalation, has good linearity and stability, and is small enough to fit inside the stoma button of a laryngectomee. The system employs two fast-response self-heated thermistors placed on opposing sides of an aerodynamic obstacle inside a tube; flow polarity discrimination is based on differences between the heat exchange patterns under laminar vs. turbulent flow. An output proportional to airflow is achieved by the connection of a circuit with a piecewise-linear transfer characteristic in cascade with the thermistors. Developed in-house, this circuit may be adjusted to create an arbitrary range of input-output characteristics. Applications are suggested for an input device for various handicapped aids, for medical diagnostics and in industrial control.</p>","PeriodicalId":75597,"journal":{"name":"Biomaterials, medical devices, and artificial organs","volume":"9 1","pages":"73-90"},"PeriodicalIF":0.0000,"publicationDate":"1981-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.3109/10731198109117603","citationCount":"0","resultStr":"{\"title\":\"Bidirectional subminiature thermistor sensor for analog control by breath flow.\",\"authors\":\"A Sekey,&nbsp;C Seagrave\",\"doi\":\"10.3109/10731198109117603\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>A subminiature airflow sensor is described, which can discriminate between exhalation and inhalation, has good linearity and stability, and is small enough to fit inside the stoma button of a laryngectomee. The system employs two fast-response self-heated thermistors placed on opposing sides of an aerodynamic obstacle inside a tube; flow polarity discrimination is based on differences between the heat exchange patterns under laminar vs. turbulent flow. An output proportional to airflow is achieved by the connection of a circuit with a piecewise-linear transfer characteristic in cascade with the thermistors. Developed in-house, this circuit may be adjusted to create an arbitrary range of input-output characteristics. Applications are suggested for an input device for various handicapped aids, for medical diagnostics and in industrial control.</p>\",\"PeriodicalId\":75597,\"journal\":{\"name\":\"Biomaterials, medical devices, and artificial organs\",\"volume\":\"9 1\",\"pages\":\"73-90\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1981-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.3109/10731198109117603\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Biomaterials, medical devices, and artificial organs\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3109/10731198109117603\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biomaterials, medical devices, and artificial organs","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3109/10731198109117603","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本文描述了一种微型气流传感器,该传感器可以区分呼出和吸入,具有良好的线性度和稳定性,并且足够小,可以安装在喉切除器的造口按钮内。该系统采用两个快速响应的自热热敏电阻,放置在管内空气动力障碍的两侧;流动极性的区分是基于层流和湍流下热交换模式的差异。通过与热敏电阻级联连接具有分段线性传输特性的电路,可以实现与气流成比例的输出。内部开发,该电路可以调整,以创建一个任意范围的输入输出特性。建议作为各种残疾人辅助设备的输入装置,用于医疗诊断和工业控制。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Bidirectional subminiature thermistor sensor for analog control by breath flow.

A subminiature airflow sensor is described, which can discriminate between exhalation and inhalation, has good linearity and stability, and is small enough to fit inside the stoma button of a laryngectomee. The system employs two fast-response self-heated thermistors placed on opposing sides of an aerodynamic obstacle inside a tube; flow polarity discrimination is based on differences between the heat exchange patterns under laminar vs. turbulent flow. An output proportional to airflow is achieved by the connection of a circuit with a piecewise-linear transfer characteristic in cascade with the thermistors. Developed in-house, this circuit may be adjusted to create an arbitrary range of input-output characteristics. Applications are suggested for an input device for various handicapped aids, for medical diagnostics and in industrial control.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信