淋巴系统的外科病理生理学。

W L Olszewski
{"title":"淋巴系统的外科病理生理学。","authors":"W L Olszewski","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>The cannulation of lymph vessels by means of polyethylene Clay-Adams P 60 tube were through out in legs of 25 normal men. The lymph quantity, the contents of immunoglobulin and complement as well as cells and the pressure were measured. Rhythmic contractions of lymph vessels may be a major determinant of lymph flow. The pressure ranged between 20 and 50 mmHg. Leg lymph flow and protein concentration undergo major 24 hr variation dependent on the position of the body and the type of activity. At night lymph flow while in the rest is low. A continuous decrease in lymph protein concentration observed while in the upright position may be explained by the wash-out of proteins accumulated during periods in the horizontal position. The immune defence in the interstitial fluid and lymph of normal tissues seems to be weaker than in blood. Antibodies have definite biological properties. The contents of leucocyte and erythrocyte in human leg lymph is discussed.</p>","PeriodicalId":76842,"journal":{"name":"Zeitschrift fur experimentelle Chirurgie","volume":"14 1","pages":"9-20"},"PeriodicalIF":0.0000,"publicationDate":"1981-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Surgical pathophysiology of the lymphatic system.\",\"authors\":\"W L Olszewski\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The cannulation of lymph vessels by means of polyethylene Clay-Adams P 60 tube were through out in legs of 25 normal men. The lymph quantity, the contents of immunoglobulin and complement as well as cells and the pressure were measured. Rhythmic contractions of lymph vessels may be a major determinant of lymph flow. The pressure ranged between 20 and 50 mmHg. Leg lymph flow and protein concentration undergo major 24 hr variation dependent on the position of the body and the type of activity. At night lymph flow while in the rest is low. A continuous decrease in lymph protein concentration observed while in the upright position may be explained by the wash-out of proteins accumulated during periods in the horizontal position. The immune defence in the interstitial fluid and lymph of normal tissues seems to be weaker than in blood. Antibodies have definite biological properties. The contents of leucocyte and erythrocyte in human leg lymph is discussed.</p>\",\"PeriodicalId\":76842,\"journal\":{\"name\":\"Zeitschrift fur experimentelle Chirurgie\",\"volume\":\"14 1\",\"pages\":\"9-20\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1981-02-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Zeitschrift fur experimentelle Chirurgie\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Zeitschrift fur experimentelle Chirurgie","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

采用聚乙烯粘土-亚当斯p60管对25例正常男性的腿部进行淋巴管插管。测定淋巴量、免疫球蛋白和补体含量、细胞和压力。淋巴管有节奏的收缩可能是淋巴流动的主要决定因素。血压在20到50毫米汞柱之间。腿部淋巴流量和蛋白质浓度在24小时内会发生很大的变化,这取决于身体的位置和活动的类型。夜间淋巴流量较低。直立体位时观察到的淋巴蛋白浓度持续下降可能是由于水平体位期间积累的蛋白质被冲洗掉了。正常组织的间质液和淋巴中的免疫防御似乎比血液中的弱。抗体具有明确的生物学特性。讨论了人腿淋巴中白细胞和红细胞的含量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Surgical pathophysiology of the lymphatic system.

The cannulation of lymph vessels by means of polyethylene Clay-Adams P 60 tube were through out in legs of 25 normal men. The lymph quantity, the contents of immunoglobulin and complement as well as cells and the pressure were measured. Rhythmic contractions of lymph vessels may be a major determinant of lymph flow. The pressure ranged between 20 and 50 mmHg. Leg lymph flow and protein concentration undergo major 24 hr variation dependent on the position of the body and the type of activity. At night lymph flow while in the rest is low. A continuous decrease in lymph protein concentration observed while in the upright position may be explained by the wash-out of proteins accumulated during periods in the horizontal position. The immune defence in the interstitial fluid and lymph of normal tissues seems to be weaker than in blood. Antibodies have definite biological properties. The contents of leucocyte and erythrocyte in human leg lymph is discussed.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信