J Ebben, R Wilson, D Hanna, M Burau, C Kjellstrand
{"title":"四个新的透析器。","authors":"J Ebben, R Wilson, D Hanna, M Burau, C Kjellstrand","doi":"10.3109/08860228009065338","DOIUrl":null,"url":null,"abstract":"<p><p>Dialyzers with a variety of sizes and performance characteristics are presently available for the dialysis of adult patients. We evaluated four currently available disposable adult dialyzers in vitro and in vivo during treatment of adult patients. All four dialyzers, Gambro GLP 1.36m2, 17 mu, Cordis Dow 3500, Gambro GF 120M, and Travenol HD 1000 were well suited to the dialysis of adult patients. By considering the clinical status of the patients and the performance characteristics of the dialyzer (solute removal, priming volume, ultrafiltration, etc.) it is possible to employ a hemodialyzer which more precisely meets the needs of the patient without increasing risk factors associated with hemodialysis.</p>","PeriodicalId":75998,"journal":{"name":"Journal of dialysis","volume":"4 4","pages":"147-58"},"PeriodicalIF":0.0000,"publicationDate":"1980-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.3109/08860228009065338","citationCount":"1","resultStr":"{\"title\":\"Four new dialyzers.\",\"authors\":\"J Ebben, R Wilson, D Hanna, M Burau, C Kjellstrand\",\"doi\":\"10.3109/08860228009065338\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Dialyzers with a variety of sizes and performance characteristics are presently available for the dialysis of adult patients. We evaluated four currently available disposable adult dialyzers in vitro and in vivo during treatment of adult patients. All four dialyzers, Gambro GLP 1.36m2, 17 mu, Cordis Dow 3500, Gambro GF 120M, and Travenol HD 1000 were well suited to the dialysis of adult patients. By considering the clinical status of the patients and the performance characteristics of the dialyzer (solute removal, priming volume, ultrafiltration, etc.) it is possible to employ a hemodialyzer which more precisely meets the needs of the patient without increasing risk factors associated with hemodialysis.</p>\",\"PeriodicalId\":75998,\"journal\":{\"name\":\"Journal of dialysis\",\"volume\":\"4 4\",\"pages\":\"147-58\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1980-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.3109/08860228009065338\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of dialysis\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3109/08860228009065338\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of dialysis","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3109/08860228009065338","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1
摘要
目前有各种尺寸和性能特点的透析器可用于成人患者的透析。我们评估了四种目前可用的一次性成人透析器在体外和体内治疗成人患者。Gambro GLP 1.36m2、17亩、Cordis Dow 3500、Gambro GF 120M、Travenol HD 1000四种透析器都非常适合成人患者的透析。通过考虑患者的临床状况和透析器的性能特点(溶质去除、启动体积、超滤等),可以采用更精确地满足患者需求的血液透析器,而不会增加与血液透析相关的危险因素。
Dialyzers with a variety of sizes and performance characteristics are presently available for the dialysis of adult patients. We evaluated four currently available disposable adult dialyzers in vitro and in vivo during treatment of adult patients. All four dialyzers, Gambro GLP 1.36m2, 17 mu, Cordis Dow 3500, Gambro GF 120M, and Travenol HD 1000 were well suited to the dialysis of adult patients. By considering the clinical status of the patients and the performance characteristics of the dialyzer (solute removal, priming volume, ultrafiltration, etc.) it is possible to employ a hemodialyzer which more precisely meets the needs of the patient without increasing risk factors associated with hemodialysis.