{"title":"[5岁以下儿童喉镜和/或支气管镜全身麻醉100例[作者简介]]。","authors":"L Versichelen, G Rolly, P Kluyskens, H Vermeersch","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>The authors describe an anesthetic technique used for endoscopies (laryngo-tracheo-bronchoscopies) in 100 children under five years age. Three different apparatus for jet ventilation are used: manual injection, automatic injection and high frequency positive pressure ventilation. The first apparatus is home made. It allows control of insufflation of O2 by manual compression of a gun type injector. With the second one (Wolf injectomat), injection of O2 or O2/N2O is automatic. The aga bronchovent is used for high frequency positive ventilation with O2.</p>","PeriodicalId":7785,"journal":{"name":"Anesthesie, analgesie, reanimation","volume":"38 9-10","pages":"463-7"},"PeriodicalIF":0.0000,"publicationDate":"1981-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"[Hundred cases of general anesthesia for laryngoscopy and/or bronchoscopy, in children under five years age (author's transl)].\",\"authors\":\"L Versichelen, G Rolly, P Kluyskens, H Vermeersch\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The authors describe an anesthetic technique used for endoscopies (laryngo-tracheo-bronchoscopies) in 100 children under five years age. Three different apparatus for jet ventilation are used: manual injection, automatic injection and high frequency positive pressure ventilation. The first apparatus is home made. It allows control of insufflation of O2 by manual compression of a gun type injector. With the second one (Wolf injectomat), injection of O2 or O2/N2O is automatic. The aga bronchovent is used for high frequency positive ventilation with O2.</p>\",\"PeriodicalId\":7785,\"journal\":{\"name\":\"Anesthesie, analgesie, reanimation\",\"volume\":\"38 9-10\",\"pages\":\"463-7\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1981-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Anesthesie, analgesie, reanimation\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Anesthesie, analgesie, reanimation","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
[Hundred cases of general anesthesia for laryngoscopy and/or bronchoscopy, in children under five years age (author's transl)].
The authors describe an anesthetic technique used for endoscopies (laryngo-tracheo-bronchoscopies) in 100 children under five years age. Three different apparatus for jet ventilation are used: manual injection, automatic injection and high frequency positive pressure ventilation. The first apparatus is home made. It allows control of insufflation of O2 by manual compression of a gun type injector. With the second one (Wolf injectomat), injection of O2 or O2/N2O is automatic. The aga bronchovent is used for high frequency positive ventilation with O2.