新生隐球菌实验性小鼠尿毒症的auxographic检测。

R A Fromtling, A M Fromtling, F Staib
{"title":"新生隐球菌实验性小鼠尿毒症的auxographic检测。","authors":"R A Fromtling,&nbsp;A M Fromtling,&nbsp;F Staib","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>A modified blood residual nitrogen plate auxanographic method was applied to the detection of experimental uremia in a murine model. The yeast-like fungus, Cryptococcus neoformans, was used as the indicator. Transient uremia was induced by injection of 0.2 ml glycerol intramuscularly. The low molecular weight nitrogen levels were estimated by measuring the diameter of the auxanogram at intervals of 2 hr for 24 hr and at 32 hr after the glycerol injection. After 4 hr, elevated levels of low molecular weight nitrogen were found. Maximum levels occurred 20 hr post glycerol injection. This method requires only 5 microliter of whole blood per assay. The results can be read after an incubation time of 24 hr at 26 degree C. The stability of the prepared plates was determined to be at least 96 hr at 4 degree C. The ease of use, reliability and versatility of the modified auxanographic method are discussed.</p>","PeriodicalId":23929,"journal":{"name":"Zentralblatt fur Bakteriologie. 1. Abt. Originale. A: Medizinische Mikrobiologie, Infektionskrankheiten und Parasitologie","volume":"248 2","pages":"268-73"},"PeriodicalIF":0.0000,"publicationDate":"1980-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Auxanographic detection of experimental murine uremia with Cryptococcus neoformans.\",\"authors\":\"R A Fromtling,&nbsp;A M Fromtling,&nbsp;F Staib\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>A modified blood residual nitrogen plate auxanographic method was applied to the detection of experimental uremia in a murine model. The yeast-like fungus, Cryptococcus neoformans, was used as the indicator. Transient uremia was induced by injection of 0.2 ml glycerol intramuscularly. The low molecular weight nitrogen levels were estimated by measuring the diameter of the auxanogram at intervals of 2 hr for 24 hr and at 32 hr after the glycerol injection. After 4 hr, elevated levels of low molecular weight nitrogen were found. Maximum levels occurred 20 hr post glycerol injection. This method requires only 5 microliter of whole blood per assay. The results can be read after an incubation time of 24 hr at 26 degree C. The stability of the prepared plates was determined to be at least 96 hr at 4 degree C. The ease of use, reliability and versatility of the modified auxanographic method are discussed.</p>\",\"PeriodicalId\":23929,\"journal\":{\"name\":\"Zentralblatt fur Bakteriologie. 1. Abt. Originale. A: Medizinische Mikrobiologie, Infektionskrankheiten und Parasitologie\",\"volume\":\"248 2\",\"pages\":\"268-73\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1980-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Zentralblatt fur Bakteriologie. 1. Abt. Originale. A: Medizinische Mikrobiologie, Infektionskrankheiten und Parasitologie\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Zentralblatt fur Bakteriologie. 1. Abt. Originale. A: Medizinische Mikrobiologie, Infektionskrankheiten und Parasitologie","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

采用改良血残氮板辅助造影术检测小鼠实验性尿毒症。以酵母样真菌新型隐球菌为指示剂。肌内注射甘油0.2 ml诱导短暂性尿毒症。在注射甘油后的2小时、24小时和32小时,通过测量辅助图直径来估计低分子量氮水平。4小时后,发现低分子量氮水平升高。甘油注射后20小时出现最高水平。这种方法每次检测只需要5微升全血。结果可在26℃下孵育24小时后读取,制备的板在4℃下的稳定性至少为96小时。讨论了改进的辅助造像方法的易用性、可靠性和通用性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Auxanographic detection of experimental murine uremia with Cryptococcus neoformans.

A modified blood residual nitrogen plate auxanographic method was applied to the detection of experimental uremia in a murine model. The yeast-like fungus, Cryptococcus neoformans, was used as the indicator. Transient uremia was induced by injection of 0.2 ml glycerol intramuscularly. The low molecular weight nitrogen levels were estimated by measuring the diameter of the auxanogram at intervals of 2 hr for 24 hr and at 32 hr after the glycerol injection. After 4 hr, elevated levels of low molecular weight nitrogen were found. Maximum levels occurred 20 hr post glycerol injection. This method requires only 5 microliter of whole blood per assay. The results can be read after an incubation time of 24 hr at 26 degree C. The stability of the prepared plates was determined to be at least 96 hr at 4 degree C. The ease of use, reliability and versatility of the modified auxanographic method are discussed.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信