{"title":"微波辐射测量控制的微波热疗:技术方面和初步临床结果。","authors":"M Chivé, M Plancot, G Giaux, B Prevost","doi":"10.1080/16070658.1984.11689370","DOIUrl":null,"url":null,"abstract":"<p><p>Microwave systems combining microwave heating generators (434, 915 or 2450 MHz) with microwave radiometers (1-2 GHz or 2-4 GHz) have been used for two years in hyperthermia therapy. Technical aspects (generator, radiometer, applicator), experiments and first clinical results are detailed.</p>","PeriodicalId":76653,"journal":{"name":"The Journal of microwave power","volume":"19 4","pages":"233-41"},"PeriodicalIF":0.0000,"publicationDate":"1984-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1080/16070658.1984.11689370","citationCount":"31","resultStr":"{\"title\":\"Microwave hyperthermia controlled by microwave radiometry: technical aspects and first clinical results.\",\"authors\":\"M Chivé, M Plancot, G Giaux, B Prevost\",\"doi\":\"10.1080/16070658.1984.11689370\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Microwave systems combining microwave heating generators (434, 915 or 2450 MHz) with microwave radiometers (1-2 GHz or 2-4 GHz) have been used for two years in hyperthermia therapy. Technical aspects (generator, radiometer, applicator), experiments and first clinical results are detailed.</p>\",\"PeriodicalId\":76653,\"journal\":{\"name\":\"The Journal of microwave power\",\"volume\":\"19 4\",\"pages\":\"233-41\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1984-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1080/16070658.1984.11689370\",\"citationCount\":\"31\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"The Journal of microwave power\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1080/16070658.1984.11689370\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Journal of microwave power","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/16070658.1984.11689370","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Microwave hyperthermia controlled by microwave radiometry: technical aspects and first clinical results.
Microwave systems combining microwave heating generators (434, 915 or 2450 MHz) with microwave radiometers (1-2 GHz or 2-4 GHz) have been used for two years in hyperthermia therapy. Technical aspects (generator, radiometer, applicator), experiments and first clinical results are detailed.