{"title":"一种简单的离子流量计,用于测量非常小的空气流速。","authors":"W M Jones, D Maidment, D V Morgan","doi":"10.1088/0022-3735/1/6/309","DOIUrl":null,"url":null,"abstract":"A prototype direct-reading ionic flowmeter to measure rates of flow of air as low as 0·37 μg S−1 has been constructed. The flowmeter functions best at a pressure of 15 torr. A discharge is struck in the air and the discharge current is fixed at about 50 μA. Two ionization chambers are placed symmetrically in a Perspex tube, one on either side of the discharge. Currents through the ionization chambers are arranged in opposition so that there is a null reading on a Vibron electrometer when there is no air flow. When flow of air does occur some ions are carried out of the upstream ionization chamber while some ions are carried into the downstream chamber; the consequent differential current in the electrometer is about 2 pA when the flow is 0·37 μg s−1. The differential current increases linearly with the rate of flow of air at 6 μA (g s−1)−1 up to rates of flow of about 10 μg s−1; thereafter the relationship between differential current and rate of flow departs from linearity, reaching a maximum at a rate of flow of around 0·1 mg s−1. The behaviour of the flowmeter may best be described by regarding the ions as diffusing from the discharge (without recombination) to the ionization chambers.","PeriodicalId":16983,"journal":{"name":"Journal of Scientific Instruments","volume":"2 1","pages":"623-7"},"PeriodicalIF":0.0000,"publicationDate":"1968-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1088/0022-3735/1/6/309","citationCount":"4","resultStr":"{\"title\":\"A simple ionic flowmeter for measuring very small rates of flow of air.\",\"authors\":\"W M Jones, D Maidment, D V Morgan\",\"doi\":\"10.1088/0022-3735/1/6/309\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A prototype direct-reading ionic flowmeter to measure rates of flow of air as low as 0·37 μg S−1 has been constructed. The flowmeter functions best at a pressure of 15 torr. A discharge is struck in the air and the discharge current is fixed at about 50 μA. Two ionization chambers are placed symmetrically in a Perspex tube, one on either side of the discharge. Currents through the ionization chambers are arranged in opposition so that there is a null reading on a Vibron electrometer when there is no air flow. When flow of air does occur some ions are carried out of the upstream ionization chamber while some ions are carried into the downstream chamber; the consequent differential current in the electrometer is about 2 pA when the flow is 0·37 μg s−1. The differential current increases linearly with the rate of flow of air at 6 μA (g s−1)−1 up to rates of flow of about 10 μg s−1; thereafter the relationship between differential current and rate of flow departs from linearity, reaching a maximum at a rate of flow of around 0·1 mg s−1. The behaviour of the flowmeter may best be described by regarding the ions as diffusing from the discharge (without recombination) to the ionization chambers.\",\"PeriodicalId\":16983,\"journal\":{\"name\":\"Journal of Scientific Instruments\",\"volume\":\"2 1\",\"pages\":\"623-7\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1968-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1088/0022-3735/1/6/309\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Scientific Instruments\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1088/0022-3735/1/6/309\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Scientific Instruments","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1088/0022-3735/1/6/309","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

摘要

本文章由计算机程序翻译,如有差异,请以英文原文为准。
A simple ionic flowmeter for measuring very small rates of flow of air.
A prototype direct-reading ionic flowmeter to measure rates of flow of air as low as 0·37 μg S−1 has been constructed. The flowmeter functions best at a pressure of 15 torr. A discharge is struck in the air and the discharge current is fixed at about 50 μA. Two ionization chambers are placed symmetrically in a Perspex tube, one on either side of the discharge. Currents through the ionization chambers are arranged in opposition so that there is a null reading on a Vibron electrometer when there is no air flow. When flow of air does occur some ions are carried out of the upstream ionization chamber while some ions are carried into the downstream chamber; the consequent differential current in the electrometer is about 2 pA when the flow is 0·37 μg s−1. The differential current increases linearly with the rate of flow of air at 6 μA (g s−1)−1 up to rates of flow of about 10 μg s−1; thereafter the relationship between differential current and rate of flow departs from linearity, reaching a maximum at a rate of flow of around 0·1 mg s−1. The behaviour of the flowmeter may best be described by regarding the ions as diffusing from the discharge (without recombination) to the ionization chambers.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信