嗜酸性粒细胞对血液透析患者肝素抗凝反应异质性的影响。

A Santoro, P Zucchelli, E Trombetti, E Degli Esposti, A Sturani, A Zuccalà, C Chiarini, M Casadei-Maldini, A Mazzuca
{"title":"嗜酸性粒细胞对血液透析患者肝素抗凝反应异质性的影响。","authors":"A Santoro,&nbsp;P Zucchelli,&nbsp;E Trombetti,&nbsp;E Degli Esposti,&nbsp;A Sturani,&nbsp;A Zuccalà,&nbsp;C Chiarini,&nbsp;M Casadei-Maldini,&nbsp;A Mazzuca","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>The anticoagulant response to heparin was determined, during haemodialysis, in a group of seven patients with eosinophilia and in a control group. The heparin half-life was similar in the two groups, but the heparin effect index was lower in patients with eosinophilia. The dose-response curve showed a reduced sensitivity to heparin in patients with eosinophilia. In patients with eosinophilia a significant reduction in eosinophil count was observed during cuprophan dialysis, but not during polyacrylonitrile dialysis. The hyposensitivity to heparin might be related to eosinophil degranulation, during cuprophan dialysis, with release of a major basic protein that neutralises heparin.</p>","PeriodicalId":77886,"journal":{"name":"Proceedings of the European Dialysis and Transplant Association - European Renal Association. European Dialysis and Transplant Association - European Renal Association. Congress","volume":"21 ","pages":"143-9"},"PeriodicalIF":0.0000,"publicationDate":"1985-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Effect of eosinophilia on the heterogeneity of the anticoagulant response to heparin in haemodialysis patients.\",\"authors\":\"A Santoro,&nbsp;P Zucchelli,&nbsp;E Trombetti,&nbsp;E Degli Esposti,&nbsp;A Sturani,&nbsp;A Zuccalà,&nbsp;C Chiarini,&nbsp;M Casadei-Maldini,&nbsp;A Mazzuca\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The anticoagulant response to heparin was determined, during haemodialysis, in a group of seven patients with eosinophilia and in a control group. The heparin half-life was similar in the two groups, but the heparin effect index was lower in patients with eosinophilia. The dose-response curve showed a reduced sensitivity to heparin in patients with eosinophilia. In patients with eosinophilia a significant reduction in eosinophil count was observed during cuprophan dialysis, but not during polyacrylonitrile dialysis. The hyposensitivity to heparin might be related to eosinophil degranulation, during cuprophan dialysis, with release of a major basic protein that neutralises heparin.</p>\",\"PeriodicalId\":77886,\"journal\":{\"name\":\"Proceedings of the European Dialysis and Transplant Association - European Renal Association. European Dialysis and Transplant Association - European Renal Association. Congress\",\"volume\":\"21 \",\"pages\":\"143-9\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1985-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the European Dialysis and Transplant Association - European Renal Association. European Dialysis and Transplant Association - European Renal Association. Congress\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the European Dialysis and Transplant Association - European Renal Association. European Dialysis and Transplant Association - European Renal Association. Congress","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

在血液透析期间,在一组7名嗜酸性粒细胞增多患者和一组对照组中测定了对肝素的抗凝反应。两组患者肝素半衰期相似,但嗜酸性粒细胞增多患者肝素效果指数较低。剂量-反应曲线显示嗜酸性粒细胞增多患者对肝素的敏感性降低。在嗜酸性粒细胞增多的患者中,在库泊芬透析期间观察到嗜酸性粒细胞计数显著减少,但在聚丙烯腈透析期间没有观察到。对肝素的低敏感性可能与库泊芬透析期间嗜酸性粒细胞脱颗粒有关,释放一种中和肝素的主要碱性蛋白。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Effect of eosinophilia on the heterogeneity of the anticoagulant response to heparin in haemodialysis patients.

The anticoagulant response to heparin was determined, during haemodialysis, in a group of seven patients with eosinophilia and in a control group. The heparin half-life was similar in the two groups, but the heparin effect index was lower in patients with eosinophilia. The dose-response curve showed a reduced sensitivity to heparin in patients with eosinophilia. In patients with eosinophilia a significant reduction in eosinophil count was observed during cuprophan dialysis, but not during polyacrylonitrile dialysis. The hyposensitivity to heparin might be related to eosinophil degranulation, during cuprophan dialysis, with release of a major basic protein that neutralises heparin.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信