{"title":"用两种计数技术估计污水中病毒密度:作为接种量函数的精度比较。","authors":"B Hugues, C Pietri, M Andre","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Two titration methods for the quantification of viruses present in the environment are compared--plaque counting and determination of the most probable number with a large number of inocula at each dilution. Titration of virus suspensions and of sewage samples showed that, for a given volume of inoculum, in most cases there was no statistically significant difference between the virus titres given by the two methods. The precision of the results was the same for the two methods. When the volume of inoculum used at each dilution differed from one method to another, the width of the confidence interval increased as the volume of inoculum decreased.</p>","PeriodicalId":77820,"journal":{"name":"Zentralblatt fur Bakteriologie, Mikrobiologie und Hygiene. 1. Abt. Originale B, Hygiene","volume":"181 3-5","pages":"409-17"},"PeriodicalIF":0.0000,"publicationDate":"1985-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Estimation of virus density in sewage effluents by two counting techniques: comparison of precisions as a function of inoculum volume.\",\"authors\":\"B Hugues, C Pietri, M Andre\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Two titration methods for the quantification of viruses present in the environment are compared--plaque counting and determination of the most probable number with a large number of inocula at each dilution. Titration of virus suspensions and of sewage samples showed that, for a given volume of inoculum, in most cases there was no statistically significant difference between the virus titres given by the two methods. The precision of the results was the same for the two methods. When the volume of inoculum used at each dilution differed from one method to another, the width of the confidence interval increased as the volume of inoculum decreased.</p>\",\"PeriodicalId\":77820,\"journal\":{\"name\":\"Zentralblatt fur Bakteriologie, Mikrobiologie und Hygiene. 1. Abt. Originale B, Hygiene\",\"volume\":\"181 3-5\",\"pages\":\"409-17\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1985-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Zentralblatt fur Bakteriologie, Mikrobiologie und Hygiene. 1. Abt. Originale B, Hygiene\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Zentralblatt fur Bakteriologie, Mikrobiologie und Hygiene. 1. Abt. Originale B, Hygiene","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Estimation of virus density in sewage effluents by two counting techniques: comparison of precisions as a function of inoculum volume.
Two titration methods for the quantification of viruses present in the environment are compared--plaque counting and determination of the most probable number with a large number of inocula at each dilution. Titration of virus suspensions and of sewage samples showed that, for a given volume of inoculum, in most cases there was no statistically significant difference between the virus titres given by the two methods. The precision of the results was the same for the two methods. When the volume of inoculum used at each dilution differed from one method to another, the width of the confidence interval increased as the volume of inoculum decreased.