反相高效液相色谱法分离不同物种生物变异胰岛素分子

D. Kalant, J.C. Crawhall, B.I. Posner
{"title":"反相高效液相色谱法分离不同物种生物变异胰岛素分子","authors":"D. Kalant,&nbsp;J.C. Crawhall,&nbsp;B.I. Posner","doi":"10.1016/0006-2944(85)90116-4","DOIUrl":null,"url":null,"abstract":"<div><p>Three different isocratic systems for the separation by reversed-phase high-performance liquid chromatography (HPLC) of different species of insulin have been investigated. The effect of different solvent compositions and temperatures on elution time and resolution have been studied. These studies have been used to devise a method for reversed-phase liquid chromatographic separation of bovine, porcine, and human insulin, as well as the A and B chains of bovine insulin. The method can also be used for the separation of the various products of the iodination of porcine insulin. <sup>125</sup>I-A14 tyrosine-labeled porcine insulin can be readily separated from nonlabeled porcine insulin and from other idoinated constitutents of the mixture. A flow-though gamma-counting system that was designed for this work is described.</p></div>","PeriodicalId":8781,"journal":{"name":"Biochemical medicine","volume":"34 2","pages":"Pages 230-240"},"PeriodicalIF":0.0000,"publicationDate":"1985-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/0006-2944(85)90116-4","citationCount":"7","resultStr":"{\"title\":\"Separation of biological variant insulin molecules from different species by reversed-phase high-performance liquid chromatography (HPLC)\",\"authors\":\"D. Kalant,&nbsp;J.C. Crawhall,&nbsp;B.I. Posner\",\"doi\":\"10.1016/0006-2944(85)90116-4\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>Three different isocratic systems for the separation by reversed-phase high-performance liquid chromatography (HPLC) of different species of insulin have been investigated. The effect of different solvent compositions and temperatures on elution time and resolution have been studied. These studies have been used to devise a method for reversed-phase liquid chromatographic separation of bovine, porcine, and human insulin, as well as the A and B chains of bovine insulin. The method can also be used for the separation of the various products of the iodination of porcine insulin. <sup>125</sup>I-A14 tyrosine-labeled porcine insulin can be readily separated from nonlabeled porcine insulin and from other idoinated constitutents of the mixture. A flow-though gamma-counting system that was designed for this work is described.</p></div>\",\"PeriodicalId\":8781,\"journal\":{\"name\":\"Biochemical medicine\",\"volume\":\"34 2\",\"pages\":\"Pages 230-240\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1985-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1016/0006-2944(85)90116-4\",\"citationCount\":\"7\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Biochemical medicine\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/0006294485901164\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biochemical medicine","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/0006294485901164","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 7

摘要

研究了三种不同的反相高效液相色谱系统分离不同种类胰岛素的方法。研究了不同溶剂组成和温度对洗脱时间和分辨率的影响。这些研究已经被用来设计一种反相液相色谱分离牛、猪和人胰岛素的方法,以及牛胰岛素的a链和B链。该方法也可用于猪胰岛素碘化的各种产物的分离。125I-A14酪氨酸标记的猪胰岛素可以很容易地从未标记的猪胰岛素和混合物的其他标记成分中分离出来。本文描述了一种为这项工作设计的流式伽马计数系统。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Separation of biological variant insulin molecules from different species by reversed-phase high-performance liquid chromatography (HPLC)

Three different isocratic systems for the separation by reversed-phase high-performance liquid chromatography (HPLC) of different species of insulin have been investigated. The effect of different solvent compositions and temperatures on elution time and resolution have been studied. These studies have been used to devise a method for reversed-phase liquid chromatographic separation of bovine, porcine, and human insulin, as well as the A and B chains of bovine insulin. The method can also be used for the separation of the various products of the iodination of porcine insulin. 125I-A14 tyrosine-labeled porcine insulin can be readily separated from nonlabeled porcine insulin and from other idoinated constitutents of the mixture. A flow-though gamma-counting system that was designed for this work is described.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信