周围气道粘液清除。

J E Agnew, D Pavia, M T Lopez-Vidriero, S W Clarke
{"title":"周围气道粘液清除。","authors":"J E Agnew,&nbsp;D Pavia,&nbsp;M T Lopez-Vidriero,&nbsp;S W Clarke","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Mucociliary clearance data obtained with 5 microns radioaerosol particles have been analyzed for asymptomatic young cigarette smokes and non-smokers. The rate and the amount of peripheral zone clearance were both considered in relationship to the overall depth of radioaerosol lung penetration. In the smokers, but not in the non-smokers, the forms of relationship found appeared compatible with prediction based on simple mathematical modelling of aerosol deposition sites within the lung. We suggest that the results found in the non-smokers are attributable to poor mucociliary defence (which is rarely required) of their more distal peripheral airways--due presumably to low levels of cross-linked glycoprotein mucus in these airways--whilst those in the smokers functionally reflect the presence of an increased supply of mucus appropriate for mucociliary transport.</p>","PeriodicalId":12048,"journal":{"name":"European journal of respiratory diseases. Supplement","volume":"153 ","pages":"150-8"},"PeriodicalIF":0.0000,"publicationDate":"1987-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Mucus clearance from peripheral airways.\",\"authors\":\"J E Agnew,&nbsp;D Pavia,&nbsp;M T Lopez-Vidriero,&nbsp;S W Clarke\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Mucociliary clearance data obtained with 5 microns radioaerosol particles have been analyzed for asymptomatic young cigarette smokes and non-smokers. The rate and the amount of peripheral zone clearance were both considered in relationship to the overall depth of radioaerosol lung penetration. In the smokers, but not in the non-smokers, the forms of relationship found appeared compatible with prediction based on simple mathematical modelling of aerosol deposition sites within the lung. We suggest that the results found in the non-smokers are attributable to poor mucociliary defence (which is rarely required) of their more distal peripheral airways--due presumably to low levels of cross-linked glycoprotein mucus in these airways--whilst those in the smokers functionally reflect the presence of an increased supply of mucus appropriate for mucociliary transport.</p>\",\"PeriodicalId\":12048,\"journal\":{\"name\":\"European journal of respiratory diseases. Supplement\",\"volume\":\"153 \",\"pages\":\"150-8\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1987-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"European journal of respiratory diseases. Supplement\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"European journal of respiratory diseases. Supplement","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

对无症状的年轻吸烟者和非吸烟者用5微米放射性气溶胶颗粒获得的纤毛粘膜清除数据进行了分析。外周区清除的速率和数量都考虑了与放射性气溶胶肺部穿透的总深度的关系。在吸烟者中,而不是在非吸烟者中,发现的关系形式似乎与基于肺部气溶胶沉积位置的简单数学模型的预测相一致。我们认为,在非吸烟者中发现的结果可归因于其远端末梢气道的粘膜纤毛防御能力差(这是很少需要的)——可能是由于这些气道中交联糖蛋白粘液水平较低——而吸烟者的结果在功能上反映了适合粘膜纤毛运输的粘液供应增加的存在。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Mucus clearance from peripheral airways.

Mucociliary clearance data obtained with 5 microns radioaerosol particles have been analyzed for asymptomatic young cigarette smokes and non-smokers. The rate and the amount of peripheral zone clearance were both considered in relationship to the overall depth of radioaerosol lung penetration. In the smokers, but not in the non-smokers, the forms of relationship found appeared compatible with prediction based on simple mathematical modelling of aerosol deposition sites within the lung. We suggest that the results found in the non-smokers are attributable to poor mucociliary defence (which is rarely required) of their more distal peripheral airways--due presumably to low levels of cross-linked glycoprotein mucus in these airways--whilst those in the smokers functionally reflect the presence of an increased supply of mucus appropriate for mucociliary transport.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信