Daiki Onodera, Masato Suzuki, Aya Katsura, Toshihiko Abe, Shin-Ichi Oikawa, Jun Suzuki, Ryoukichi Ikeda
{"title":"内镜下与三维外窥镜下鼓室乳突切除术治疗原发性中耳胆脂瘤的比较。","authors":"Daiki Onodera, Masato Suzuki, Aya Katsura, Toshihiko Abe, Shin-Ichi Oikawa, Jun Suzuki, Ryoukichi Ikeda","doi":"10.1080/00016489.2025.2570789","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The three-dimensional (3D) exoscope is an emerging alternative to the operating microscope (OM) in otologic surgery.</p><p><strong>Aims: </strong>To assess its clinical utility in cholesteatoma surgery.</p><p><strong>Methods: </strong>Retrospective review of 36 primary cases (21 OM, 15 exoscope) comparing setup time, surgical duration, audiological outcomes, and recurrence.</p><p><strong>Results: </strong>Groups were comparable in background and stage. Setup time was shorter with exoscope (microscope: 20 min, range 18-22, exoscope: 17 min, range 14-20) (<i>p</i> = .002), while other outcomes showed no significant difference.</p><p><strong>Conclusions: </strong>The 3D exoscope reduced setup time with equivalent surgical and functional outcomes to OM.</p>","PeriodicalId":6880,"journal":{"name":"Acta Oto-Laryngologica","volume":" ","pages":"1-6"},"PeriodicalIF":1.0000,"publicationDate":"2025-10-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Comparison of microscopic and 3D exoscopic canal wall down tympanomastoidectomy for primary middle ear cholesteatoma.\",\"authors\":\"Daiki Onodera, Masato Suzuki, Aya Katsura, Toshihiko Abe, Shin-Ichi Oikawa, Jun Suzuki, Ryoukichi Ikeda\",\"doi\":\"10.1080/00016489.2025.2570789\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>The three-dimensional (3D) exoscope is an emerging alternative to the operating microscope (OM) in otologic surgery.</p><p><strong>Aims: </strong>To assess its clinical utility in cholesteatoma surgery.</p><p><strong>Methods: </strong>Retrospective review of 36 primary cases (21 OM, 15 exoscope) comparing setup time, surgical duration, audiological outcomes, and recurrence.</p><p><strong>Results: </strong>Groups were comparable in background and stage. Setup time was shorter with exoscope (microscope: 20 min, range 18-22, exoscope: 17 min, range 14-20) (<i>p</i> = .002), while other outcomes showed no significant difference.</p><p><strong>Conclusions: </strong>The 3D exoscope reduced setup time with equivalent surgical and functional outcomes to OM.</p>\",\"PeriodicalId\":6880,\"journal\":{\"name\":\"Acta Oto-Laryngologica\",\"volume\":\" \",\"pages\":\"1-6\"},\"PeriodicalIF\":1.0000,\"publicationDate\":\"2025-10-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Acta Oto-Laryngologica\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1080/00016489.2025.2570789\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"OTORHINOLARYNGOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta Oto-Laryngologica","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1080/00016489.2025.2570789","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"OTORHINOLARYNGOLOGY","Score":null,"Total":0}
Comparison of microscopic and 3D exoscopic canal wall down tympanomastoidectomy for primary middle ear cholesteatoma.
Background: The three-dimensional (3D) exoscope is an emerging alternative to the operating microscope (OM) in otologic surgery.
Aims: To assess its clinical utility in cholesteatoma surgery.
Methods: Retrospective review of 36 primary cases (21 OM, 15 exoscope) comparing setup time, surgical duration, audiological outcomes, and recurrence.
Results: Groups were comparable in background and stage. Setup time was shorter with exoscope (microscope: 20 min, range 18-22, exoscope: 17 min, range 14-20) (p = .002), while other outcomes showed no significant difference.
Conclusions: The 3D exoscope reduced setup time with equivalent surgical and functional outcomes to OM.