{"title":"硬质透气性隐形眼镜的原位氧透射率。","authors":"B A Weissman, I Fatt","doi":"10.1097/00006324-198805000-00016","DOIUrl":null,"url":null,"abstract":"<p><p>On the eye a contact lens is bathed in tear fluid, which increases its resistance to oxygen flux. For rigid gas-permeable lenses, this effect should be small during open-eye wear because a large amount of oxygen is provided by air-saturated tears that are pumped under the lens. However, under closed-eye conditions this study suggests substantial decrease in overall lens system oxygen transmissibility when lens transmissibility itself is greater than 20 x 10(-9) cm ml O2/s ml mm Hg and when the average thickness of the tear layer is greater than about 20 micron.</p>","PeriodicalId":7700,"journal":{"name":"American journal of optometry and physiological optics","volume":"65 5","pages":"400-2"},"PeriodicalIF":0.0000,"publicationDate":"1988-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1097/00006324-198805000-00016","citationCount":"1","resultStr":"{\"title\":\"In situ oxygen transmissibility of rigid gas-permeable contact lenses.\",\"authors\":\"B A Weissman, I Fatt\",\"doi\":\"10.1097/00006324-198805000-00016\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>On the eye a contact lens is bathed in tear fluid, which increases its resistance to oxygen flux. For rigid gas-permeable lenses, this effect should be small during open-eye wear because a large amount of oxygen is provided by air-saturated tears that are pumped under the lens. However, under closed-eye conditions this study suggests substantial decrease in overall lens system oxygen transmissibility when lens transmissibility itself is greater than 20 x 10(-9) cm ml O2/s ml mm Hg and when the average thickness of the tear layer is greater than about 20 micron.</p>\",\"PeriodicalId\":7700,\"journal\":{\"name\":\"American journal of optometry and physiological optics\",\"volume\":\"65 5\",\"pages\":\"400-2\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1988-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1097/00006324-198805000-00016\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"American journal of optometry and physiological optics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1097/00006324-198805000-00016\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"American journal of optometry and physiological optics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1097/00006324-198805000-00016","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1
摘要
在眼睛上,隐形眼镜浸泡在泪液中,这增加了它对氧气通量的抵抗力。对于刚性透气性镜片,这种影响在睁眼佩戴时应该很小,因为大量的氧气是由泵入镜片下的空气饱和泪液提供的。然而,在闭眼条件下,本研究表明,当晶状体本身的透氧率大于20 × 10(-9) cm ml O2/s ml mm Hg且泪液层的平均厚度大于约20微米时,晶状体系统的整体透氧率会大幅下降。
In situ oxygen transmissibility of rigid gas-permeable contact lenses.
On the eye a contact lens is bathed in tear fluid, which increases its resistance to oxygen flux. For rigid gas-permeable lenses, this effect should be small during open-eye wear because a large amount of oxygen is provided by air-saturated tears that are pumped under the lens. However, under closed-eye conditions this study suggests substantial decrease in overall lens system oxygen transmissibility when lens transmissibility itself is greater than 20 x 10(-9) cm ml O2/s ml mm Hg and when the average thickness of the tear layer is greater than about 20 micron.