{"title":"超高清成像在百万安培球形托卡马克。","authors":"A M Patel, N J Conway, S S Henderson","doi":"10.1063/5.0252851","DOIUrl":null,"url":null,"abstract":"<p><p>An absolutely calibrated, visible imaging diagnostic has been deployed on the MAST spherical tokamak. Two sets of three-color channels are defined using a combination of stacked multi-cavity interference filters, color-glass filter, and a color-pixel sensor. The system is compact with a single viewing pupil, which facilitates unambiguous comparisons of measurements in 2D. The sensor has a 12-bit dynamic range, 50 μs to 10 ms integration time (with 100-200 Hz frame rate), and a wide field of view with 640 × 480 resolution. The center-wavelength and the spectral bandpass for all colors are maintained across the field of view as they are controlled in the optical telecentric domain. The design views a complete plasma cross section, which contains passive plasma-edge and active interior emissions: one of the two neutral beam emissions, plasma-impurity charge-exchange emissions from both equator neutral beams, and two colors of bremsstrahlung.</p>","PeriodicalId":21111,"journal":{"name":"Review of Scientific Instruments","volume":"96 5","pages":""},"PeriodicalIF":1.3000,"publicationDate":"2025-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"High definition imaging in the Mega Amp Spherical Tokamak.\",\"authors\":\"A M Patel, N J Conway, S S Henderson\",\"doi\":\"10.1063/5.0252851\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>An absolutely calibrated, visible imaging diagnostic has been deployed on the MAST spherical tokamak. Two sets of three-color channels are defined using a combination of stacked multi-cavity interference filters, color-glass filter, and a color-pixel sensor. The system is compact with a single viewing pupil, which facilitates unambiguous comparisons of measurements in 2D. The sensor has a 12-bit dynamic range, 50 μs to 10 ms integration time (with 100-200 Hz frame rate), and a wide field of view with 640 × 480 resolution. The center-wavelength and the spectral bandpass for all colors are maintained across the field of view as they are controlled in the optical telecentric domain. The design views a complete plasma cross section, which contains passive plasma-edge and active interior emissions: one of the two neutral beam emissions, plasma-impurity charge-exchange emissions from both equator neutral beams, and two colors of bremsstrahlung.</p>\",\"PeriodicalId\":21111,\"journal\":{\"name\":\"Review of Scientific Instruments\",\"volume\":\"96 5\",\"pages\":\"\"},\"PeriodicalIF\":1.3000,\"publicationDate\":\"2025-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Review of Scientific Instruments\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1063/5.0252851\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"INSTRUMENTS & INSTRUMENTATION\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Review of Scientific Instruments","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1063/5.0252851","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"INSTRUMENTS & INSTRUMENTATION","Score":null,"Total":0}
High definition imaging in the Mega Amp Spherical Tokamak.
An absolutely calibrated, visible imaging diagnostic has been deployed on the MAST spherical tokamak. Two sets of three-color channels are defined using a combination of stacked multi-cavity interference filters, color-glass filter, and a color-pixel sensor. The system is compact with a single viewing pupil, which facilitates unambiguous comparisons of measurements in 2D. The sensor has a 12-bit dynamic range, 50 μs to 10 ms integration time (with 100-200 Hz frame rate), and a wide field of view with 640 × 480 resolution. The center-wavelength and the spectral bandpass for all colors are maintained across the field of view as they are controlled in the optical telecentric domain. The design views a complete plasma cross section, which contains passive plasma-edge and active interior emissions: one of the two neutral beam emissions, plasma-impurity charge-exchange emissions from both equator neutral beams, and two colors of bremsstrahlung.
期刊介绍:
Review of Scientific Instruments, is committed to the publication of advances in scientific instruments, apparatuses, and techniques. RSI seeks to meet the needs of engineers and scientists in physics, chemistry, and the life sciences.