{"title":"硬透气隐形眼镜的柔韧性。","authors":"R W Stevenson","doi":"10.1097/00006324-198811000-00004","DOIUrl":null,"url":null,"abstract":"<p><p>Gas permeable (GP) lenses can flex on some eyes producing unpredictable clinical results. A method of measuring the flexibility of hard GP materials has been developed and shown to be repeatable. Materials in the form of flats rather than lenses were used. Differences between materials were found and in general a linear relation was shown to exist between maximum flexing and quoted oxygen permeability (r = 0.78, p less than 0.05). It is recommended that flexibility be measured and reported in the data presented with all new GP polymers. The term \"hard\" rather than \"rigid\" in describing GP lenses is suggested.</p>","PeriodicalId":7700,"journal":{"name":"American journal of optometry and physiological optics","volume":"65 11","pages":"874-9"},"PeriodicalIF":0.0000,"publicationDate":"1988-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1097/00006324-198811000-00004","citationCount":"2","resultStr":"{\"title\":\"Flexibility of hard gas permeable contact lenses.\",\"authors\":\"R W Stevenson\",\"doi\":\"10.1097/00006324-198811000-00004\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Gas permeable (GP) lenses can flex on some eyes producing unpredictable clinical results. A method of measuring the flexibility of hard GP materials has been developed and shown to be repeatable. Materials in the form of flats rather than lenses were used. Differences between materials were found and in general a linear relation was shown to exist between maximum flexing and quoted oxygen permeability (r = 0.78, p less than 0.05). It is recommended that flexibility be measured and reported in the data presented with all new GP polymers. The term \\\"hard\\\" rather than \\\"rigid\\\" in describing GP lenses is suggested.</p>\",\"PeriodicalId\":7700,\"journal\":{\"name\":\"American journal of optometry and physiological optics\",\"volume\":\"65 11\",\"pages\":\"874-9\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1988-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1097/00006324-198811000-00004\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"American journal of optometry and physiological optics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1097/00006324-198811000-00004\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"American journal of optometry and physiological optics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1097/00006324-198811000-00004","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2
摘要
透气性(GP)隐形眼镜可以在某些眼睛上弯曲,产生不可预测的临床结果。一种测量硬GP材料柔韧性的方法已经开发出来,并证明是可重复的。使用了平面形式的材料而不是透镜。不同材料之间存在差异,总的来说,最大挠曲度与引用的氧渗透率之间存在线性关系(r = 0.78, p < 0.05)。建议在所有新的GP聚合物的数据中测量和报告柔韧性。建议在描述GP镜片时使用术语“硬”而不是“刚性”。
Gas permeable (GP) lenses can flex on some eyes producing unpredictable clinical results. A method of measuring the flexibility of hard GP materials has been developed and shown to be repeatable. Materials in the form of flats rather than lenses were used. Differences between materials were found and in general a linear relation was shown to exist between maximum flexing and quoted oxygen permeability (r = 0.78, p less than 0.05). It is recommended that flexibility be measured and reported in the data presented with all new GP polymers. The term "hard" rather than "rigid" in describing GP lenses is suggested.