Leos Pleva, Pavel Kukla, Tomas Kovarnik, Jana Zapletalova
{"title":"比较西罗莫司和紫杉醇洗脱球囊导管治疗冠状动脉支架内再狭窄的疗效:一项前瞻性随机研究(TIS 2研究)。","authors":"Leos Pleva, Pavel Kukla, Tomas Kovarnik, Jana Zapletalova","doi":"10.1161/CIRCINTERVENTIONS.124.014677","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Current therapy for in-stent restenosis (ISR) is based on drug-eluting stents (DES) or drug-eluting balloon catheters. This prospective randomized study compared the efficacy of a novel sirolimus-eluting balloon (SEB) catheter to that of a paclitaxel-eluting balloon (PEB) catheter for the treatment of bare-metal stent (BMS-ISR) or DES-ISR restenosis.</p><p><strong>Methods: </strong>A total of 145 patients with 158 BMS or DES-ISR lesions were randomly assigned to the treatment with either SEB or PEB. The in-segment late lumen loss at 12 months, the 12-month incidence of binary ISR, and major adverse cardiac events (cardiac death, nonfatal acute myocardial infarction, or target lesion revascularization) were compared between groups.</p><p><strong>Results: </strong>The noninferiority of SEB compared with PEB in the treatment of BMS/DES-ISR with respect to late lumen loss was not demonstrated (Δlate lumen loss, -0.024 mm [95% CI, -0.277 to 0.229]; for a noninferiority margin of 0.20 mm), except in the post hoc subanalysis for the BMS-ISR group (-0.203 mm [95% CI, -0.584 to 0.178]). No significant differences in the incidence of repeated binary ISR (31.6% versus 30.4%, <i>P</i>=0.906) or 12-month major adverse cardiac events (31% for both; <i>P</i>>0.999) between the SEB and PEB groups were observed.</p><p><strong>Conclusions: </strong>The noninferiority of SEB relative to PEB in the treatment of BMS/DES-ISR with respect to late lumen loss was not confirmed.</p><p><strong>Registration: </strong>URL: https://www.clinicaltrials.gov; Unique identifier: NCT03672656.</p>","PeriodicalId":10330,"journal":{"name":"Circulation: Cardiovascular Interventions","volume":" ","pages":"e014677"},"PeriodicalIF":6.1000,"publicationDate":"2025-04-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Comparing the Efficacy of Sirolimus and Paclitaxel-Eluting Balloon Catheters in the Treatment of Coronary In-Stent Restenosis: A Prospective Randomized Study (TIS 2 Study).\",\"authors\":\"Leos Pleva, Pavel Kukla, Tomas Kovarnik, Jana Zapletalova\",\"doi\":\"10.1161/CIRCINTERVENTIONS.124.014677\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Current therapy for in-stent restenosis (ISR) is based on drug-eluting stents (DES) or drug-eluting balloon catheters. This prospective randomized study compared the efficacy of a novel sirolimus-eluting balloon (SEB) catheter to that of a paclitaxel-eluting balloon (PEB) catheter for the treatment of bare-metal stent (BMS-ISR) or DES-ISR restenosis.</p><p><strong>Methods: </strong>A total of 145 patients with 158 BMS or DES-ISR lesions were randomly assigned to the treatment with either SEB or PEB. The in-segment late lumen loss at 12 months, the 12-month incidence of binary ISR, and major adverse cardiac events (cardiac death, nonfatal acute myocardial infarction, or target lesion revascularization) were compared between groups.</p><p><strong>Results: </strong>The noninferiority of SEB compared with PEB in the treatment of BMS/DES-ISR with respect to late lumen loss was not demonstrated (Δlate lumen loss, -0.024 mm [95% CI, -0.277 to 0.229]; for a noninferiority margin of 0.20 mm), except in the post hoc subanalysis for the BMS-ISR group (-0.203 mm [95% CI, -0.584 to 0.178]). No significant differences in the incidence of repeated binary ISR (31.6% versus 30.4%, <i>P</i>=0.906) or 12-month major adverse cardiac events (31% for both; <i>P</i>>0.999) between the SEB and PEB groups were observed.</p><p><strong>Conclusions: </strong>The noninferiority of SEB relative to PEB in the treatment of BMS/DES-ISR with respect to late lumen loss was not confirmed.</p><p><strong>Registration: </strong>URL: https://www.clinicaltrials.gov; Unique identifier: NCT03672656.</p>\",\"PeriodicalId\":10330,\"journal\":{\"name\":\"Circulation: Cardiovascular Interventions\",\"volume\":\" \",\"pages\":\"e014677\"},\"PeriodicalIF\":6.1000,\"publicationDate\":\"2025-04-02\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Circulation: Cardiovascular Interventions\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1161/CIRCINTERVENTIONS.124.014677\",\"RegionNum\":1,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Circulation: Cardiovascular Interventions","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1161/CIRCINTERVENTIONS.124.014677","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0
摘要
背景:目前支架内再狭窄(ISR)的治疗是基于药物洗脱支架(DES)或药物洗脱球囊导管。这项前瞻性随机研究比较了新型西罗莫司洗脱球囊(SEB)导管与紫杉醇洗脱球囊(PEB)导管治疗裸金属支架(BMS-ISR)或DES-ISR再狭窄的疗效。方法:145例BMS或DES-ISR患者共158例,随机分为SEB组和PEB组。比较两组间12个月时段内晚期管腔损失、12个月二元ISR发生率和主要心脏不良事件(心源性死亡、非致死性急性心肌梗死或靶病变血运重建)。结果:未证明SEB与PEB在治疗BMS/DES-ISR时晚期管腔损失方面的非劣效性(Δlate管腔损失,-0.024 mm [95% CI, -0.277至0.229];除BMS-ISR组的事后亚分析(-0.203 mm [95% CI, -0.584至0.178])外,非劣效性边际为0.20 mm。重复二元ISR发生率(31.6%对30.4%,P=0.906)或12个月主要不良心脏事件发生率(两者均为31%;SEB组与PEB组间P < 0.05)。结论:SEB相对于PEB在治疗BMS/DES-ISR的晚期管腔损失方面的非劣效性尚未得到证实。注册:网址:https://www.clinicaltrials.gov;唯一标识符:NCT03672656。
Comparing the Efficacy of Sirolimus and Paclitaxel-Eluting Balloon Catheters in the Treatment of Coronary In-Stent Restenosis: A Prospective Randomized Study (TIS 2 Study).
Background: Current therapy for in-stent restenosis (ISR) is based on drug-eluting stents (DES) or drug-eluting balloon catheters. This prospective randomized study compared the efficacy of a novel sirolimus-eluting balloon (SEB) catheter to that of a paclitaxel-eluting balloon (PEB) catheter for the treatment of bare-metal stent (BMS-ISR) or DES-ISR restenosis.
Methods: A total of 145 patients with 158 BMS or DES-ISR lesions were randomly assigned to the treatment with either SEB or PEB. The in-segment late lumen loss at 12 months, the 12-month incidence of binary ISR, and major adverse cardiac events (cardiac death, nonfatal acute myocardial infarction, or target lesion revascularization) were compared between groups.
Results: The noninferiority of SEB compared with PEB in the treatment of BMS/DES-ISR with respect to late lumen loss was not demonstrated (Δlate lumen loss, -0.024 mm [95% CI, -0.277 to 0.229]; for a noninferiority margin of 0.20 mm), except in the post hoc subanalysis for the BMS-ISR group (-0.203 mm [95% CI, -0.584 to 0.178]). No significant differences in the incidence of repeated binary ISR (31.6% versus 30.4%, P=0.906) or 12-month major adverse cardiac events (31% for both; P>0.999) between the SEB and PEB groups were observed.
Conclusions: The noninferiority of SEB relative to PEB in the treatment of BMS/DES-ISR with respect to late lumen loss was not confirmed.
期刊介绍:
Circulation: Cardiovascular Interventions, an American Heart Association journal, focuses on interventional techniques pertaining to coronary artery disease, structural heart disease, and vascular disease, with priority placed on original research and on randomized trials and large registry studies. In addition, pharmacological, diagnostic, and pathophysiological aspects of interventional cardiology are given special attention in this online-only journal.