{"title":"胸壁和经食管刺激在永久性起搏器患者功能评估中的应用。","authors":"S Cotoi, E Caraşca, A Incze","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>For the functional estimation of artificial pacemakers, we have used two techniques: chest-wall stimulation and transesophageal stimulation. Transesophageal stimulation was always effective in inhibiting the generator, and it was used when chest-wall stimulation was ineffective. These two tests can be easily performed and are of remarkable usefulness in the follow-up of patients with permanent pacemaker.</p>","PeriodicalId":76129,"journal":{"name":"Medecine interne","volume":"26 4","pages":"323-7"},"PeriodicalIF":0.0000,"publicationDate":"1988-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Chest-wall and transesophageal stimulation in the functional evaluation of patients with permanent pacemakers.\",\"authors\":\"S Cotoi, E Caraşca, A Incze\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>For the functional estimation of artificial pacemakers, we have used two techniques: chest-wall stimulation and transesophageal stimulation. Transesophageal stimulation was always effective in inhibiting the generator, and it was used when chest-wall stimulation was ineffective. These two tests can be easily performed and are of remarkable usefulness in the follow-up of patients with permanent pacemaker.</p>\",\"PeriodicalId\":76129,\"journal\":{\"name\":\"Medecine interne\",\"volume\":\"26 4\",\"pages\":\"323-7\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1988-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Medecine interne\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Medecine interne","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Chest-wall and transesophageal stimulation in the functional evaluation of patients with permanent pacemakers.
For the functional estimation of artificial pacemakers, we have used two techniques: chest-wall stimulation and transesophageal stimulation. Transesophageal stimulation was always effective in inhibiting the generator, and it was used when chest-wall stimulation was ineffective. These two tests can be easily performed and are of remarkable usefulness in the follow-up of patients with permanent pacemaker.