无导线起搏器的长期管理。

IF 1.7 4区 医学 Q3 CARDIAC & CARDIOVASCULAR SYSTEMS
European Heart Journal Supplements Pub Date : 2025-03-24 eCollection Date: 2025-03-01 DOI:10.1093/eurheartjsupp/suae119
Andrew Andreae, Alexander Breitenstein, Jonathan P Piccini
{"title":"无导线起搏器的长期管理。","authors":"Andrew Andreae, Alexander Breitenstein, Jonathan P Piccini","doi":"10.1093/eurheartjsupp/suae119","DOIUrl":null,"url":null,"abstract":"<p><p>Leadless pacemakers (LPs) are increasingly being used to treat bradyarrhythmias, and end of service (EOS) management decisions are becoming increasingly important given finite battery lifespans. Two strategies have been adopted for device EOS: LP abandonment and LP removal. Certain scenarios including high degree of LP encapsulation and 'last expected' pacing devices favour LP abandonment, while other LP complications may necessitate device removal. When abandoning LP, clinicians must understand design, performance, and safety considerations for devices left in place. When removing LP, specialized tools and techniques have been developed, each varying by device manufacturer and model. Case reports and series on LP removal have elucidated how to overcome challenges that may arise during removal. Despite best practice techniques, complications can arise before and after removal. Current studies on LP EOS management are limited, and further studies are needed to help understand predictors of successful device removal and long-term sequelae of both strategies. The aim of this state-of-the-art review is to help clinicians understand current strategies and considerations for both LP abandonment and removal.</p>","PeriodicalId":11956,"journal":{"name":"European Heart Journal Supplements","volume":"27 Suppl 2","pages":"ii26-ii38"},"PeriodicalIF":1.7000,"publicationDate":"2025-03-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11932086/pdf/","citationCount":"0","resultStr":"{\"title\":\"Long-term management of leadless pacemakers.\",\"authors\":\"Andrew Andreae, Alexander Breitenstein, Jonathan P Piccini\",\"doi\":\"10.1093/eurheartjsupp/suae119\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Leadless pacemakers (LPs) are increasingly being used to treat bradyarrhythmias, and end of service (EOS) management decisions are becoming increasingly important given finite battery lifespans. Two strategies have been adopted for device EOS: LP abandonment and LP removal. Certain scenarios including high degree of LP encapsulation and 'last expected' pacing devices favour LP abandonment, while other LP complications may necessitate device removal. When abandoning LP, clinicians must understand design, performance, and safety considerations for devices left in place. When removing LP, specialized tools and techniques have been developed, each varying by device manufacturer and model. Case reports and series on LP removal have elucidated how to overcome challenges that may arise during removal. Despite best practice techniques, complications can arise before and after removal. Current studies on LP EOS management are limited, and further studies are needed to help understand predictors of successful device removal and long-term sequelae of both strategies. The aim of this state-of-the-art review is to help clinicians understand current strategies and considerations for both LP abandonment and removal.</p>\",\"PeriodicalId\":11956,\"journal\":{\"name\":\"European Heart Journal Supplements\",\"volume\":\"27 Suppl 2\",\"pages\":\"ii26-ii38\"},\"PeriodicalIF\":1.7000,\"publicationDate\":\"2025-03-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11932086/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"European Heart Journal Supplements\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1093/eurheartjsupp/suae119\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2025/3/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q3\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Heart Journal Supplements","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1093/eurheartjsupp/suae119","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/3/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

摘要

无铅起搏器(lp)越来越多地被用于治疗慢速心律失常,由于电池寿命有限,服务结束(EOS)管理决策变得越来越重要。设备EOS采用了两种策略:LP放弃和LP移除。某些情况下,包括LP高度包封和“最后预期”起搏器,倾向于放弃LP,而其他LP并发症可能需要移除设备。当放弃LP时,临床医生必须了解遗留设备的设计、性能和安全考虑。在移除LP时,已经开发了专门的工具和技术,每种工具和技术都因设备制造商和型号而异。关于LP移除的病例报告和系列已经阐明了如何克服移除过程中可能出现的挑战。尽管采用了最佳实践技术,但手术前后仍可能出现并发症。目前关于LP EOS管理的研究是有限的,需要进一步的研究来帮助了解成功移除设备的预测因素和两种策略的长期后遗症。本综述的目的是帮助临床医生了解当前LP放弃和切除的策略和考虑因素。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Long-term management of leadless pacemakers.

Leadless pacemakers (LPs) are increasingly being used to treat bradyarrhythmias, and end of service (EOS) management decisions are becoming increasingly important given finite battery lifespans. Two strategies have been adopted for device EOS: LP abandonment and LP removal. Certain scenarios including high degree of LP encapsulation and 'last expected' pacing devices favour LP abandonment, while other LP complications may necessitate device removal. When abandoning LP, clinicians must understand design, performance, and safety considerations for devices left in place. When removing LP, specialized tools and techniques have been developed, each varying by device manufacturer and model. Case reports and series on LP removal have elucidated how to overcome challenges that may arise during removal. Despite best practice techniques, complications can arise before and after removal. Current studies on LP EOS management are limited, and further studies are needed to help understand predictors of successful device removal and long-term sequelae of both strategies. The aim of this state-of-the-art review is to help clinicians understand current strategies and considerations for both LP abandonment and removal.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
European Heart Journal Supplements
European Heart Journal Supplements 医学-心血管系统
CiteScore
3.00
自引率
0.00%
发文量
575
审稿时长
12 months
期刊介绍: The European Heart Journal Supplements (EHJs) is a long standing member of the ESC Journal Family that serves as a publication medium for supplemental issues of the flagship European Heart Journal. Traditionally EHJs published a broad range of articles from symposia to special issues on specific topics of interest. The Editor-in-Chief, Professor Roberto Ferrari, together with his team of eminent Associate Editors: Professor Francisco Fernández-Avilés, Professors Jeroen Bax, Michael Böhm, Frank Ruschitzka, and Thomas Lüscher from the European Heart Journal, has implemented a change of focus for the journal. This entirely refreshed version of the European Heart Journal Supplements now bears the subtitle the Heart of the Matter to give recognition to the focus the journal now has. The EHJs – the Heart of the Matter intends to offer a dedicated, scientific space for the ESC, Institutions, National and Affiliate Societies, Associations, Working Groups and Councils to disseminate their important successes globally.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信