前列腺磁共振成像快速自旋回波 T2 加权成像中出现运动伪影的风险因素:一项回顾性研究。

IF 1.7 Q3 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Takuya Kobata, Tatsuya Yamasaki, Hiroki Katayama, Masatoshi Morimoto, Yukito Maeda, Takashi Norikane, Yuka Yamamoto, Yoshihiro Nishiyama
{"title":"前列腺磁共振成像快速自旋回波 T2 加权成像中出现运动伪影的风险因素:一项回顾性研究。","authors":"Takuya Kobata, Tatsuya Yamasaki, Hiroki Katayama, Masatoshi Morimoto, Yukito Maeda, Takashi Norikane, Yuka Yamamoto, Yoshihiro Nishiyama","doi":"10.1007/s12194-025-00897-z","DOIUrl":null,"url":null,"abstract":"<p><p>Prostate cancer diagnosis using fast spin-echo (FSE) T2-weight imaging (T2WI) suffers from motion artifacts (T2-MA). We aimed to investigate the risk factors associated with T2-MA. We retrospectively analyzed the basic patient information and localizer images of 168 patients who underwent prostate magnetic resonance imaging at our institution between April 2019 and December 2021. FSE T2WI image quality was classified into Poor, Acceptable, and Excellent groups based on T2-MA severity. Between-group differences were analyzed using the Kruskal-Wallis test, and multinomial logistic regression was used to calculate adjusted odds ratios (ORs) for T2-MA. The bladder area of the Acceptable group was significantly larger than that of the Poor group (P = 0.010). The rectal area was significantly larger in the Poor group than in the Excellent group (P = 0.013). Larger rectal and bladder areas in the localizer image were significant risk factors for severe (OR: 1.136) and mild (OR: 1.032) T2-MA, respectively.</p>","PeriodicalId":46252,"journal":{"name":"Radiological Physics and Technology","volume":" ","pages":""},"PeriodicalIF":1.7000,"publicationDate":"2025-03-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Risk factors for motion artifacts in fast spin-echo T2-weighted imaging of the prostate magnetic resonance imaging: a retrospective study.\",\"authors\":\"Takuya Kobata, Tatsuya Yamasaki, Hiroki Katayama, Masatoshi Morimoto, Yukito Maeda, Takashi Norikane, Yuka Yamamoto, Yoshihiro Nishiyama\",\"doi\":\"10.1007/s12194-025-00897-z\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Prostate cancer diagnosis using fast spin-echo (FSE) T2-weight imaging (T2WI) suffers from motion artifacts (T2-MA). We aimed to investigate the risk factors associated with T2-MA. We retrospectively analyzed the basic patient information and localizer images of 168 patients who underwent prostate magnetic resonance imaging at our institution between April 2019 and December 2021. FSE T2WI image quality was classified into Poor, Acceptable, and Excellent groups based on T2-MA severity. Between-group differences were analyzed using the Kruskal-Wallis test, and multinomial logistic regression was used to calculate adjusted odds ratios (ORs) for T2-MA. The bladder area of the Acceptable group was significantly larger than that of the Poor group (P = 0.010). The rectal area was significantly larger in the Poor group than in the Excellent group (P = 0.013). Larger rectal and bladder areas in the localizer image were significant risk factors for severe (OR: 1.136) and mild (OR: 1.032) T2-MA, respectively.</p>\",\"PeriodicalId\":46252,\"journal\":{\"name\":\"Radiological Physics and Technology\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":1.7000,\"publicationDate\":\"2025-03-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Radiological Physics and Technology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1007/s12194-025-00897-z\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Radiological Physics and Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1007/s12194-025-00897-z","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

摘要

本文章由计算机程序翻译,如有差异,请以英文原文为准。
Risk factors for motion artifacts in fast spin-echo T2-weighted imaging of the prostate magnetic resonance imaging: a retrospective study.

Prostate cancer diagnosis using fast spin-echo (FSE) T2-weight imaging (T2WI) suffers from motion artifacts (T2-MA). We aimed to investigate the risk factors associated with T2-MA. We retrospectively analyzed the basic patient information and localizer images of 168 patients who underwent prostate magnetic resonance imaging at our institution between April 2019 and December 2021. FSE T2WI image quality was classified into Poor, Acceptable, and Excellent groups based on T2-MA severity. Between-group differences were analyzed using the Kruskal-Wallis test, and multinomial logistic regression was used to calculate adjusted odds ratios (ORs) for T2-MA. The bladder area of the Acceptable group was significantly larger than that of the Poor group (P = 0.010). The rectal area was significantly larger in the Poor group than in the Excellent group (P = 0.013). Larger rectal and bladder areas in the localizer image were significant risk factors for severe (OR: 1.136) and mild (OR: 1.032) T2-MA, respectively.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Radiological Physics and Technology
Radiological Physics and Technology RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
3.00
自引率
12.50%
发文量
40
期刊介绍: The purpose of the journal Radiological Physics and Technology is to provide a forum for sharing new knowledge related to research and development in radiological science and technology, including medical physics and radiological technology in diagnostic radiology, nuclear medicine, and radiation therapy among many other radiological disciplines, as well as to contribute to progress and improvement in medical practice and patient health care.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信