压力导丝用于冠状动脉分流血流储备评估:结构设计、缺陷和潜在解决方案。

IF 2.1 3区 医学 Q3 CARDIAC & CARDIOVASCULAR SYSTEMS
Wengang Liu, Jun Shi, Rong Shan, Yu Wang, Liangfeng Zhao, Honglei Zhou, Wei Li, Liuliu Feng
{"title":"压力导丝用于冠状动脉分流血流储备评估:结构设计、缺陷和潜在解决方案。","authors":"Wengang Liu, Jun Shi, Rong Shan, Yu Wang, Liangfeng Zhao, Honglei Zhou, Wei Li, Liuliu Feng","doi":"10.1002/ccd.31504","DOIUrl":null,"url":null,"abstract":"<p><p>Coronary heart disease (CHD) is one of the leading causes of mortality worldwide. It is primarily caused by myocardial ischemia and hypoxia resulting from atherosclerotic plaques in the coronary arteries, leading to symptoms such as angina. The severity of CHD determines the treatment approach, which may include medication or interventional therapy. Therefore, accurately assessing the severity of myocardial ischemia is crucial for effective CHD management. In recent years, fractional flow reserve (FFR), derived from the relationship between flow and pressure, has gained widespread recognition for providing valuable information to guide coronary revascularization. Pressure guidewires equipped with pressure sensors at their tips are the most commonly used tools for clinical FFR assessment. These wires measure vessel pressure to determine the severity of coronary lesions. However, during their use, issues such as signal drift, tip breakage, core wire fractures, and coating detachment may occur. This article reviews the historical development of pressure guidewires, examines the general structure of two commonly used pressure guidewires available in the market, highlights typical issues encountered during clinical use, and proposes corresponding solutions.</p>","PeriodicalId":9650,"journal":{"name":"Catheterization and Cardiovascular Interventions","volume":" ","pages":""},"PeriodicalIF":2.1000,"publicationDate":"2025-03-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Pressure Guidewire Indicated for Coronary Fractional Flow Reserve Assessment: Structural Design, Deficiencies and Potential Solutions.\",\"authors\":\"Wengang Liu, Jun Shi, Rong Shan, Yu Wang, Liangfeng Zhao, Honglei Zhou, Wei Li, Liuliu Feng\",\"doi\":\"10.1002/ccd.31504\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Coronary heart disease (CHD) is one of the leading causes of mortality worldwide. It is primarily caused by myocardial ischemia and hypoxia resulting from atherosclerotic plaques in the coronary arteries, leading to symptoms such as angina. The severity of CHD determines the treatment approach, which may include medication or interventional therapy. Therefore, accurately assessing the severity of myocardial ischemia is crucial for effective CHD management. In recent years, fractional flow reserve (FFR), derived from the relationship between flow and pressure, has gained widespread recognition for providing valuable information to guide coronary revascularization. Pressure guidewires equipped with pressure sensors at their tips are the most commonly used tools for clinical FFR assessment. These wires measure vessel pressure to determine the severity of coronary lesions. However, during their use, issues such as signal drift, tip breakage, core wire fractures, and coating detachment may occur. This article reviews the historical development of pressure guidewires, examines the general structure of two commonly used pressure guidewires available in the market, highlights typical issues encountered during clinical use, and proposes corresponding solutions.</p>\",\"PeriodicalId\":9650,\"journal\":{\"name\":\"Catheterization and Cardiovascular Interventions\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":2.1000,\"publicationDate\":\"2025-03-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Catheterization and Cardiovascular Interventions\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1002/ccd.31504\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Catheterization and Cardiovascular Interventions","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1002/ccd.31504","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

摘要

冠心病(CHD)是世界范围内导致死亡的主要原因之一。主要是由于冠状动脉粥样硬化斑块导致心肌缺血缺氧,导致心绞痛等症状。冠心病的严重程度决定了治疗方法,可能包括药物治疗或介入治疗。因此,准确评估心肌缺血的严重程度对冠心病的有效治疗至关重要。近年来,从血流和压力关系中导出的血流储备分数(FFR)为指导冠状动脉血运重建提供了有价值的信息,得到了广泛的认可。在其尖端配备压力传感器的压力导丝是临床评估FFR最常用的工具。这些导线测量血管压力以确定冠状动脉病变的严重程度。然而,在使用过程中,可能会出现信号漂移、尖端断裂、芯线断裂和涂层脱落等问题。本文回顾了压力导丝的发展历史,分析了市场上常用的两种压力导丝的一般结构,重点介绍了临床使用中遇到的典型问题,并提出了相应的解决方案。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Pressure Guidewire Indicated for Coronary Fractional Flow Reserve Assessment: Structural Design, Deficiencies and Potential Solutions.

Coronary heart disease (CHD) is one of the leading causes of mortality worldwide. It is primarily caused by myocardial ischemia and hypoxia resulting from atherosclerotic plaques in the coronary arteries, leading to symptoms such as angina. The severity of CHD determines the treatment approach, which may include medication or interventional therapy. Therefore, accurately assessing the severity of myocardial ischemia is crucial for effective CHD management. In recent years, fractional flow reserve (FFR), derived from the relationship between flow and pressure, has gained widespread recognition for providing valuable information to guide coronary revascularization. Pressure guidewires equipped with pressure sensors at their tips are the most commonly used tools for clinical FFR assessment. These wires measure vessel pressure to determine the severity of coronary lesions. However, during their use, issues such as signal drift, tip breakage, core wire fractures, and coating detachment may occur. This article reviews the historical development of pressure guidewires, examines the general structure of two commonly used pressure guidewires available in the market, highlights typical issues encountered during clinical use, and proposes corresponding solutions.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
5.40
自引率
8.70%
发文量
419
审稿时长
2 months
期刊介绍: Catheterization and Cardiovascular Interventions is an international journal covering the broad field of cardiovascular diseases. Subject material includes basic and clinical information that is derived from or related to invasive and interventional coronary or peripheral vascular techniques. The journal focuses on material that will be of immediate practical value to physicians providing patient care in the clinical laboratory setting. To accomplish this, the journal publishes Preliminary Reports and Work In Progress articles that complement the traditional Original Studies, Case Reports, and Comprehensive Reviews. Perspective and insight concerning controversial subjects and evolving technologies are provided regularly through Editorial Commentaries furnished by members of the Editorial Board and other experts. Articles are subject to double-blind peer review and complete editorial evaluation prior to any decision regarding acceptability.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信