HISTO斑点HLA - AB与交叉配型结果的比较。

IF 2.3 4区 医学 Q3 GENETICS & HEREDITY
Madeleine R Harris, Andrew Canterbury, Judith E Worthington, MarcusP Lowe, Marie E Hampson, Kay V Poulton
{"title":"HISTO斑点HLA - AB与交叉配型结果的比较。","authors":"Madeleine R Harris, Andrew Canterbury, Judith E Worthington, MarcusP Lowe, Marie E Hampson, Kay V Poulton","doi":"10.1111/iji.12710","DOIUrl":null,"url":null,"abstract":"<p><p>Single antigen bead assays have revolutionised the identification and definition of HLA-specific antibodies and HLA-specific antibody profiles present in patients awaiting transplantation are routinely characterised to inform organ allocation. For highly sensitised patients with a lower likelihood of finding a compatible donor, de-listing of unacceptable antigens is an option to release organ offers. In this study, 164 serum samples from 106 potential renal transplant recipients were tested using HISTO SPOT HLA AB in parallel with testing by LABScreen Single Antigen (One Lambda) and cross-matching by both CDC and flow cytometry. The results were analysed to assess the ability of HISTO SPOT HLA AB to predict a cross-match result and to understand the relative sensitivity of this test compared with other available assays. 136 samples analysed were positive for donor-specific antibodies (DSAs) using HISTO SPOT HLA AB. Of these, 17 (12.5%) were CDC positive, and 82 (60.3%) were positive by flow cytometry. A total of 28 sera which were negative for DSAs using HISTO SPOT HLA AB were negative by CDC and 25 (89.3%) were also flow cytometry cross-match negative. In this early study, HISTO SPOT HLA AB has a 100% negative predictive value for CDC and 89.3% for flow cytometry cross-matching. HISTO SPOT may therefore prove a useful additional tool to inform de-listing strategies and to facilitate transplantation in highly sensitised patients.</p>","PeriodicalId":14003,"journal":{"name":"International Journal of Immunogenetics","volume":" ","pages":""},"PeriodicalIF":2.3000,"publicationDate":"2025-03-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Comparison of HISTO SPOT HLA AB With Cross-Match Results.\",\"authors\":\"Madeleine R Harris, Andrew Canterbury, Judith E Worthington, MarcusP Lowe, Marie E Hampson, Kay V Poulton\",\"doi\":\"10.1111/iji.12710\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Single antigen bead assays have revolutionised the identification and definition of HLA-specific antibodies and HLA-specific antibody profiles present in patients awaiting transplantation are routinely characterised to inform organ allocation. For highly sensitised patients with a lower likelihood of finding a compatible donor, de-listing of unacceptable antigens is an option to release organ offers. In this study, 164 serum samples from 106 potential renal transplant recipients were tested using HISTO SPOT HLA AB in parallel with testing by LABScreen Single Antigen (One Lambda) and cross-matching by both CDC and flow cytometry. The results were analysed to assess the ability of HISTO SPOT HLA AB to predict a cross-match result and to understand the relative sensitivity of this test compared with other available assays. 136 samples analysed were positive for donor-specific antibodies (DSAs) using HISTO SPOT HLA AB. Of these, 17 (12.5%) were CDC positive, and 82 (60.3%) were positive by flow cytometry. A total of 28 sera which were negative for DSAs using HISTO SPOT HLA AB were negative by CDC and 25 (89.3%) were also flow cytometry cross-match negative. In this early study, HISTO SPOT HLA AB has a 100% negative predictive value for CDC and 89.3% for flow cytometry cross-matching. HISTO SPOT may therefore prove a useful additional tool to inform de-listing strategies and to facilitate transplantation in highly sensitised patients.</p>\",\"PeriodicalId\":14003,\"journal\":{\"name\":\"International Journal of Immunogenetics\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":2.3000,\"publicationDate\":\"2025-03-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Immunogenetics\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1111/iji.12710\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"GENETICS & HEREDITY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Immunogenetics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1111/iji.12710","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"GENETICS & HEREDITY","Score":null,"Total":0}
引用次数: 0

摘要

单抗原珠检测彻底改变了hla特异性抗体的鉴定和定义,等待移植的患者中存在的hla特异性抗体谱通常被表征以告知器官分配。对于高度敏感的患者,找到相容供体的可能性较低,删除不可接受的抗原是释放器官供应的一种选择。在这项研究中,来自106名潜在肾移植受者的164份血清样本使用HISTO SPOT HLA - AB进行检测,同时使用LABScreen单抗原(One Lambda)进行检测,并使用CDC和流式细胞术进行交叉匹配。对结果进行分析,以评估HISTO SPOT HLA AB预测交叉匹配结果的能力,并了解该测试与其他可用检测方法相比的相对敏感性。经HISTO SPOT HLA - AB检测,136份供体特异性抗体(dsa)阳性,其中CDC阳性17份(12.5%),流式细胞术阳性82份(60.3%)。用HISTO SPOT HLA - AB检测dsa阴性的28份血清经CDC检测为阴性,25份(89.3%)经流式细胞术交叉配型检测为阴性。在这项早期研究中,HISTO SPOT HLA AB对CDC的阴性预测值为100%,流式细胞术交叉匹配的阴性预测值为89.3%。因此,HISTO SPOT可能被证明是一种有用的附加工具,可以为除名策略提供信息,并促进高度敏感患者的移植。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Comparison of HISTO SPOT HLA AB With Cross-Match Results.

Single antigen bead assays have revolutionised the identification and definition of HLA-specific antibodies and HLA-specific antibody profiles present in patients awaiting transplantation are routinely characterised to inform organ allocation. For highly sensitised patients with a lower likelihood of finding a compatible donor, de-listing of unacceptable antigens is an option to release organ offers. In this study, 164 serum samples from 106 potential renal transplant recipients were tested using HISTO SPOT HLA AB in parallel with testing by LABScreen Single Antigen (One Lambda) and cross-matching by both CDC and flow cytometry. The results were analysed to assess the ability of HISTO SPOT HLA AB to predict a cross-match result and to understand the relative sensitivity of this test compared with other available assays. 136 samples analysed were positive for donor-specific antibodies (DSAs) using HISTO SPOT HLA AB. Of these, 17 (12.5%) were CDC positive, and 82 (60.3%) were positive by flow cytometry. A total of 28 sera which were negative for DSAs using HISTO SPOT HLA AB were negative by CDC and 25 (89.3%) were also flow cytometry cross-match negative. In this early study, HISTO SPOT HLA AB has a 100% negative predictive value for CDC and 89.3% for flow cytometry cross-matching. HISTO SPOT may therefore prove a useful additional tool to inform de-listing strategies and to facilitate transplantation in highly sensitised patients.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
4.70
自引率
0.00%
发文量
48
审稿时长
6-12 weeks
期刊介绍: The International Journal of Immunogenetics (formerly European Journal of Immunogenetics) publishes original contributions on the genetic control of components of the immune system and their interactions in both humans and experimental animals. The term ''genetic'' is taken in its broadest sense to include studies at the evolutionary, molecular, chromosomal functional and population levels in both health and disease. Examples are: -studies of blood groups and other surface antigens- cell interactions and immune response- receptors, antibodies, complement components and cytokines- polymorphism- evolution of the organisation, control and function of immune system components- anthropology and disease associations- the genetics of immune-related disease: allergy, autoimmunity, immunodeficiency and other immune pathologies- All papers are seen by at least two independent referees and only papers of the highest quality are accepted.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信