电增强固相微萃取-气相色谱-氮磷检测器灵敏测定人类毛发中的苯丙胺类兴奋剂

IF 1.2 4区 化学 Q4 CHEMISTRY, ANALYTICAL
Aiying SONG , Rong LIU , Xinghe HE , Linlin WEI
{"title":"电增强固相微萃取-气相色谱-氮磷检测器灵敏测定人类毛发中的苯丙胺类兴奋剂","authors":"Aiying SONG ,&nbsp;Rong LIU ,&nbsp;Xinghe HE ,&nbsp;Linlin WEI","doi":"10.1016/j.cjac.2025.100525","DOIUrl":null,"url":null,"abstract":"<div><div>In the field of forensic sciences, the analysis of amphetamine-type stimulants in hair samples has become a fundamental tool for assessing long-term substance use. The persistent nature of amphetamine-type stimulants in hair provides a unique chronological record of drug intake, offering valuable insights for legal and clinical applications. Developing a simple, sensitive, and reliable method for the determination of these drugs in hair samples remains an important issue in forensic analysis. In this study, polydimethylsiloxane modified stainless steel fiber was firstly fabricated. By taking advantage of the affinity of the polydimethylsiloxane coating toward amphetamine-type stimulants and the excellent conductivity of stainless steel wire, an electro-enhanced solid-phase microextraction coupled with gas chromatography equipped with a nitrogen-phosphorus detector method was established to sensitively determine four common amphetamine-type stimulants in hair samples. The experimental results showed a linear range from 0.1 to 50 µg L⁻¹. The limits of detection and qualification respectively varied from 0.012 to 0.039 and 0.05 to 0.13 µg L⁻¹ (<em>S</em>/<em>N</em> = 3), and it exhibited good reproducibility (&lt; 6.2%). Recoveries ranging from 79% to 106%, with a relative standard deviation of &lt; 6.7%, were obtained for all analytes. Fiber-to-fiber reproducibility (RSD), obtained using three fibers, was &lt; 8.8%. The developed strategy combined the affinity of the polydimethylsiloxane coating towards amphetamine-type stimulants with the electrical conductivity of the stainless steel wire, effectively improving the enrichment ability and detection sensitivity, and achieving simultaneous selective enrichment and detection of several analytes. This is a simple, efficient, and reliable method for the analysis of amphetamine-type stimulants from complex matrices.</div></div>","PeriodicalId":277,"journal":{"name":"Chinese Journal of Analytical Chemistry","volume":"53 4","pages":"Article 100525"},"PeriodicalIF":1.2000,"publicationDate":"2025-03-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Sensitive determination of amphetamine-type stimulants in human hair by electro-enhanced solid-phase microextraction coupled to gas chromatography with nitrogen-phosphorus detector\",\"authors\":\"Aiying SONG ,&nbsp;Rong LIU ,&nbsp;Xinghe HE ,&nbsp;Linlin WEI\",\"doi\":\"10.1016/j.cjac.2025.100525\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><div>In the field of forensic sciences, the analysis of amphetamine-type stimulants in hair samples has become a fundamental tool for assessing long-term substance use. The persistent nature of amphetamine-type stimulants in hair provides a unique chronological record of drug intake, offering valuable insights for legal and clinical applications. Developing a simple, sensitive, and reliable method for the determination of these drugs in hair samples remains an important issue in forensic analysis. In this study, polydimethylsiloxane modified stainless steel fiber was firstly fabricated. By taking advantage of the affinity of the polydimethylsiloxane coating toward amphetamine-type stimulants and the excellent conductivity of stainless steel wire, an electro-enhanced solid-phase microextraction coupled with gas chromatography equipped with a nitrogen-phosphorus detector method was established to sensitively determine four common amphetamine-type stimulants in hair samples. The experimental results showed a linear range from 0.1 to 50 µg L⁻¹. The limits of detection and qualification respectively varied from 0.012 to 0.039 and 0.05 to 0.13 µg L⁻¹ (<em>S</em>/<em>N</em> = 3), and it exhibited good reproducibility (&lt; 6.2%). Recoveries ranging from 79% to 106%, with a relative standard deviation of &lt; 6.7%, were obtained for all analytes. Fiber-to-fiber reproducibility (RSD), obtained using three fibers, was &lt; 8.8%. The developed strategy combined the affinity of the polydimethylsiloxane coating towards amphetamine-type stimulants with the electrical conductivity of the stainless steel wire, effectively improving the enrichment ability and detection sensitivity, and achieving simultaneous selective enrichment and detection of several analytes. This is a simple, efficient, and reliable method for the analysis of amphetamine-type stimulants from complex matrices.</div></div>\",\"PeriodicalId\":277,\"journal\":{\"name\":\"Chinese Journal of Analytical Chemistry\",\"volume\":\"53 4\",\"pages\":\"Article 100525\"},\"PeriodicalIF\":1.2000,\"publicationDate\":\"2025-03-06\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Chinese Journal of Analytical Chemistry\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S1872204025000350\",\"RegionNum\":4,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Chinese Journal of Analytical Chemistry","FirstCategoryId":"92","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1872204025000350","RegionNum":4,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

摘要

在法医学领域,分析毛发样本中的苯丙胺类兴奋剂已成为评估长期药物使用情况的基本工具。苯丙胺类兴奋剂在毛发中的持久性为药物摄入提供了独特的时间记录,为法律和临床应用提供了宝贵的见解。开发一种简单、灵敏、可靠的方法来测定毛发样本中的这类药物仍然是法医分析中的一个重要问题。本研究首先制备了聚二甲基硅氧烷改性不锈钢纤维。利用聚二甲基硅氧烷涂层对苯丙胺类兴奋剂的亲和性和不锈钢丝良好的导电性,建立了电增强固相微萃取-气相色谱-氮磷检测器联用方法,灵敏地测定了毛发样品中四种常见的苯丙胺类兴奋剂。实验结果表明,其线性范围为 0.1 至 50 µg L-¹。检出限和定性限分别为 0.012 至 0.039 和 0.05 至 0.13 µg L-¹(信噪比为 3),重现性良好(6.2%)。所有分析物的回收率为 79% 至 106%,相对标准偏差为 6.7%。使用三根纤维获得的纤维间重现性(RSD)为 8.8%。所开发的策略将聚二甲基硅氧烷涂层对苯丙胺类兴奋剂的亲和性与不锈钢丝的导电性相结合,有效提高了富集能力和检测灵敏度,实现了对多种分析物的同时选择性富集和检测。该方法简单、高效、可靠,适用于复杂基质中苯丙胺类兴奋剂的分析。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Sensitive determination of amphetamine-type stimulants in human hair by electro-enhanced solid-phase microextraction coupled to gas chromatography with nitrogen-phosphorus detector

Sensitive determination of amphetamine-type stimulants in human hair by electro-enhanced solid-phase microextraction coupled to gas chromatography with nitrogen-phosphorus detector
In the field of forensic sciences, the analysis of amphetamine-type stimulants in hair samples has become a fundamental tool for assessing long-term substance use. The persistent nature of amphetamine-type stimulants in hair provides a unique chronological record of drug intake, offering valuable insights for legal and clinical applications. Developing a simple, sensitive, and reliable method for the determination of these drugs in hair samples remains an important issue in forensic analysis. In this study, polydimethylsiloxane modified stainless steel fiber was firstly fabricated. By taking advantage of the affinity of the polydimethylsiloxane coating toward amphetamine-type stimulants and the excellent conductivity of stainless steel wire, an electro-enhanced solid-phase microextraction coupled with gas chromatography equipped with a nitrogen-phosphorus detector method was established to sensitively determine four common amphetamine-type stimulants in hair samples. The experimental results showed a linear range from 0.1 to 50 µg L⁻¹. The limits of detection and qualification respectively varied from 0.012 to 0.039 and 0.05 to 0.13 µg L⁻¹ (S/N = 3), and it exhibited good reproducibility (< 6.2%). Recoveries ranging from 79% to 106%, with a relative standard deviation of < 6.7%, were obtained for all analytes. Fiber-to-fiber reproducibility (RSD), obtained using three fibers, was < 8.8%. The developed strategy combined the affinity of the polydimethylsiloxane coating towards amphetamine-type stimulants with the electrical conductivity of the stainless steel wire, effectively improving the enrichment ability and detection sensitivity, and achieving simultaneous selective enrichment and detection of several analytes. This is a simple, efficient, and reliable method for the analysis of amphetamine-type stimulants from complex matrices.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
3.60
自引率
25.00%
发文量
17223
审稿时长
35 days
期刊介绍: Chinese Journal of Analytical Chemistry(CJAC) is an academic journal of analytical chemistry established in 1972 and sponsored by the Chinese Chemical Society and Changchun Institute of Applied Chemistry, Chinese Academy of Sciences. Its objectives are to report the original scientific research achievements and review the recent development of analytical chemistry in all areas. The journal sets up 5 columns including Research Papers, Research Notes, Experimental Technique and Instrument, Review and Progress and Summary Accounts. The journal published monthly in Chinese language. A detailed abstract, keywords and the titles of figures and tables are provided in English, except column of Summary Accounts. Prof. Wang Erkang, an outstanding analytical chemist, academician of Chinese Academy of Sciences & Third World Academy of Sciences, holds the post of the Editor-in-chief.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信