x射线和伽马射线对埃及伊蚊(双翅目:库蚊科)的蛹和成虫的消毒效果没有差别。

Chao Chen, Whitney A Qualls, Rui-de Xue, Seth Gibson, Daniel A Hahn
{"title":"x射线和伽马射线对埃及伊蚊(双翅目:库蚊科)的蛹和成虫的消毒效果没有差别。","authors":"Chao Chen, Whitney A Qualls, Rui-de Xue, Seth Gibson, Daniel A Hahn","doi":"10.1093/jee/toaf030","DOIUrl":null,"url":null,"abstract":"<p><p>The sterile insect technique (SIT) is increasingly used as an alternative or supplemental tool in the integrated mosquito management toolbox to protect human health worldwide. SIT programs targeting mosquitoes such as Aedes aegypti (L.) have generally used high-activity isotopes of 60Cobalt or 137Caesium to sterilize males, however, these gamma irradiators pose substantial security challenges and are becoming more difficult and expensive to obtain and maintain. One practical alternative is using commercially available low-energy X-ray irradiators. In this study, we compared the efficacy of a low-energy X-ray irradiator and a traditional gamma irradiator for achieving male sterility in both male pupae and adults of the mosquito Ae. aegypti Linn. We found that both irradiators performed equivalently with 99% sterility achieved at ~50 Gy when male pupae were irradiated and ~70 Gy when male adults were irradiated. There were no differences in lifespan or male mating competitiveness at the sterilizing dose between the 2 irradiation platforms. Taken together, our results suggest that with careful dosimetry X-ray irradiators can effectively be used as an alternative to gamma irradiators in SIT programs targeting Ae. aegypti.</p>","PeriodicalId":94077,"journal":{"name":"Journal of economic entomology","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2025-03-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"X-rays and gamma rays do not differ in their effectiveness for sterilizing pupae and adults of the mosquito Aedes aegypti (Diptera: Culicidae).\",\"authors\":\"Chao Chen, Whitney A Qualls, Rui-de Xue, Seth Gibson, Daniel A Hahn\",\"doi\":\"10.1093/jee/toaf030\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The sterile insect technique (SIT) is increasingly used as an alternative or supplemental tool in the integrated mosquito management toolbox to protect human health worldwide. SIT programs targeting mosquitoes such as Aedes aegypti (L.) have generally used high-activity isotopes of 60Cobalt or 137Caesium to sterilize males, however, these gamma irradiators pose substantial security challenges and are becoming more difficult and expensive to obtain and maintain. One practical alternative is using commercially available low-energy X-ray irradiators. In this study, we compared the efficacy of a low-energy X-ray irradiator and a traditional gamma irradiator for achieving male sterility in both male pupae and adults of the mosquito Ae. aegypti Linn. We found that both irradiators performed equivalently with 99% sterility achieved at ~50 Gy when male pupae were irradiated and ~70 Gy when male adults were irradiated. There were no differences in lifespan or male mating competitiveness at the sterilizing dose between the 2 irradiation platforms. Taken together, our results suggest that with careful dosimetry X-ray irradiators can effectively be used as an alternative to gamma irradiators in SIT programs targeting Ae. aegypti.</p>\",\"PeriodicalId\":94077,\"journal\":{\"name\":\"Journal of economic entomology\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2025-03-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of economic entomology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1093/jee/toaf030\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of economic entomology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1093/jee/toaf030","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

在世界范围内,昆虫不育技术作为一种替代或补充手段在蚊虫综合管理工具箱中得到越来越多的应用,以保护人类健康。针对埃及伊蚊(Aedes aegypti, L.)等蚊子的SIT项目通常使用60钴或137铯的高活性同位素对雄性蚊子进行绝育,然而,这些伽马射线带来了重大的安全挑战,并且越来越难以获得和维护。一个实用的替代方案是使用市售的低能x射线辐照器。在这项研究中,我们比较了低能x射线照射器和传统伽马照射器对伊蚊雄蛹和成虫的不育效果。蚊绝壁。我们发现两种辐射剂在~50 Gy照射下雄性蛹和~70 Gy照射下雄性成虫的不育率均达到99%。两种辐照平台在绝育剂量下的寿命和雄性交配竞争能力均无差异。综上所述,我们的研究结果表明,通过仔细的剂量测定,x射线照射可以有效地用作靶向Ae的SIT项目中伽马照射的替代方案。蚊。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
X-rays and gamma rays do not differ in their effectiveness for sterilizing pupae and adults of the mosquito Aedes aegypti (Diptera: Culicidae).

The sterile insect technique (SIT) is increasingly used as an alternative or supplemental tool in the integrated mosquito management toolbox to protect human health worldwide. SIT programs targeting mosquitoes such as Aedes aegypti (L.) have generally used high-activity isotopes of 60Cobalt or 137Caesium to sterilize males, however, these gamma irradiators pose substantial security challenges and are becoming more difficult and expensive to obtain and maintain. One practical alternative is using commercially available low-energy X-ray irradiators. In this study, we compared the efficacy of a low-energy X-ray irradiator and a traditional gamma irradiator for achieving male sterility in both male pupae and adults of the mosquito Ae. aegypti Linn. We found that both irradiators performed equivalently with 99% sterility achieved at ~50 Gy when male pupae were irradiated and ~70 Gy when male adults were irradiated. There were no differences in lifespan or male mating competitiveness at the sterilizing dose between the 2 irradiation platforms. Taken together, our results suggest that with careful dosimetry X-ray irradiators can effectively be used as an alternative to gamma irradiators in SIT programs targeting Ae. aegypti.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信