3只雄性狒狒的心脏评估和植入式循环记录仪的放置。

IF 0.7 4区 农林科学 Q3 VETERINARY SCIENCES
Stephanie H Zec, Marc Miller, Charlotte Hollinger, Lori Croft, Martin Goldman, Kathy D'Andrea, Jessica E Moody, Colleen McCann, Susan L Bartlett
{"title":"3只雄性狒狒的心脏评估和植入式循环记录仪的放置。","authors":"Stephanie H Zec, Marc Miller, Charlotte Hollinger, Lori Croft, Martin Goldman, Kathy D'Andrea, Jessica E Moody, Colleen McCann, Susan L Bartlett","doi":"10.1638/2024-0044","DOIUrl":null,"url":null,"abstract":"<p><p>Cardiac disease is a common cause of mortality in many primates housed in zoological settings. At the Bronx Zoo, between 2007 and 2018, there were ten incidences of sudden cardiac death in adult male geladas (<i>Theropithecus gelada</i>), none of which showed premonitory signs. Due to concerns of occult cardiac disease and fatal arrhythmogenic events, complete cardiac examinations were performed in three clinically normal, adult male geladas. Examinations included thoracic radiographs, transthoracic echocardiograms (echo), 12-lead ECG, and continuous ECG monitoring using an Implantable Loop Recorder (Reveal LINQ<sup>TM</sup> Medtronic, Minneapolis, MN 55432, USA). Serum lipid profiles, vitamin E concentration, cardiac troponin I isoform (cTnI), and complete blood work were also performed. Wireless downloads from the implantable loop recorders were obtained intermittently for up to 2.5 years after placement. One male had an elevated cTnI level (210 ng/L), reduced ejection fraction (46%), and multiple episodes of supraventricular tachycardia and non-sustained ventricular tachycardia. Due to the abnormalities on ECG and echo, he was treated with metoprolol and lisinopril. Treatment was continued for nearly two years, until the animal had sudden cardiac death secondary to sustained ventricular fibrillation, which was confirmed by postmortem download of the loop recorder data and correlated with histologic evidence of cardiomyopathy. Implantable loop recorders greatly enhance the ability to diagnose and treat arrhythmias in primates and understand the mechanisms behind sudden cardiac deaths. Further studies are needed to establish cTnI, echocardiogram, and electrocardiogram reference ranges for this species, as well as appropriate treatment protocols.</p>","PeriodicalId":17667,"journal":{"name":"Journal of Zoo and Wildlife Medicine","volume":"56 1","pages":"175-183"},"PeriodicalIF":0.7000,"publicationDate":"2025-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"CARDIAC ASSESSMENTS AND IMPLANTABLE LOOP RECORDER PLACEMENT IN THREE MALE GELADAS (<i>THEROPITHECUS GELADA</i>).\",\"authors\":\"Stephanie H Zec, Marc Miller, Charlotte Hollinger, Lori Croft, Martin Goldman, Kathy D'Andrea, Jessica E Moody, Colleen McCann, Susan L Bartlett\",\"doi\":\"10.1638/2024-0044\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Cardiac disease is a common cause of mortality in many primates housed in zoological settings. At the Bronx Zoo, between 2007 and 2018, there were ten incidences of sudden cardiac death in adult male geladas (<i>Theropithecus gelada</i>), none of which showed premonitory signs. Due to concerns of occult cardiac disease and fatal arrhythmogenic events, complete cardiac examinations were performed in three clinically normal, adult male geladas. Examinations included thoracic radiographs, transthoracic echocardiograms (echo), 12-lead ECG, and continuous ECG monitoring using an Implantable Loop Recorder (Reveal LINQ<sup>TM</sup> Medtronic, Minneapolis, MN 55432, USA). Serum lipid profiles, vitamin E concentration, cardiac troponin I isoform (cTnI), and complete blood work were also performed. Wireless downloads from the implantable loop recorders were obtained intermittently for up to 2.5 years after placement. One male had an elevated cTnI level (210 ng/L), reduced ejection fraction (46%), and multiple episodes of supraventricular tachycardia and non-sustained ventricular tachycardia. Due to the abnormalities on ECG and echo, he was treated with metoprolol and lisinopril. Treatment was continued for nearly two years, until the animal had sudden cardiac death secondary to sustained ventricular fibrillation, which was confirmed by postmortem download of the loop recorder data and correlated with histologic evidence of cardiomyopathy. Implantable loop recorders greatly enhance the ability to diagnose and treat arrhythmias in primates and understand the mechanisms behind sudden cardiac deaths. Further studies are needed to establish cTnI, echocardiogram, and electrocardiogram reference ranges for this species, as well as appropriate treatment protocols.</p>\",\"PeriodicalId\":17667,\"journal\":{\"name\":\"Journal of Zoo and Wildlife Medicine\",\"volume\":\"56 1\",\"pages\":\"175-183\"},\"PeriodicalIF\":0.7000,\"publicationDate\":\"2025-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Zoo and Wildlife Medicine\",\"FirstCategoryId\":\"97\",\"ListUrlMain\":\"https://doi.org/10.1638/2024-0044\",\"RegionNum\":4,\"RegionCategory\":\"农林科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"VETERINARY SCIENCES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Zoo and Wildlife Medicine","FirstCategoryId":"97","ListUrlMain":"https://doi.org/10.1638/2024-0044","RegionNum":4,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"VETERINARY SCIENCES","Score":null,"Total":0}
引用次数: 0

摘要

心脏病是许多动物环境中灵长类动物死亡的常见原因。在布朗克斯动物园,2007年至2018年期间,成年雄性狒狒(Theropithecus gelada)发生了10起心脏性猝死事件,其中没有一例出现先兆迹象。出于对隐匿性心脏病和致死性心律失常事件的担忧,我们对3只临床正常的成年雄性狒狒进行了全面的心脏检查。检查包括胸部x线片、经胸超声心动图(echo)、12导联心电图和使用可植入循环记录仪(Reveal LINQTM Medtronic, Minneapolis, MN 55432, USA)进行连续心电图监测。同时还进行了血脂、维生素E浓度、心肌肌钙蛋白I亚型(cTnI)和全血检查。在植入后的2.5年里,从可植入的环形录音机中间歇性地获得无线下载。一名男性cTnI水平升高(210 ng/L),射血分数降低(46%),多次发作室上性心动过速和非持续性室性心动过速。由于心电图和回声异常,给予美托洛尔和赖诺普利治疗。治疗持续了近两年,直到动物发生继发于持续性心室颤动的心源性猝死,通过死后下载环路记录仪数据证实了这一点,并与心肌病的组织学证据相关。植入式循环记录仪极大地提高了灵长类动物心律失常的诊断和治疗能力,并了解了心脏性猝死的机制。需要进一步的研究来建立该物种的cTnI、超声心动图和心电图参考范围,以及适当的治疗方案。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
CARDIAC ASSESSMENTS AND IMPLANTABLE LOOP RECORDER PLACEMENT IN THREE MALE GELADAS (THEROPITHECUS GELADA).

Cardiac disease is a common cause of mortality in many primates housed in zoological settings. At the Bronx Zoo, between 2007 and 2018, there were ten incidences of sudden cardiac death in adult male geladas (Theropithecus gelada), none of which showed premonitory signs. Due to concerns of occult cardiac disease and fatal arrhythmogenic events, complete cardiac examinations were performed in three clinically normal, adult male geladas. Examinations included thoracic radiographs, transthoracic echocardiograms (echo), 12-lead ECG, and continuous ECG monitoring using an Implantable Loop Recorder (Reveal LINQTM Medtronic, Minneapolis, MN 55432, USA). Serum lipid profiles, vitamin E concentration, cardiac troponin I isoform (cTnI), and complete blood work were also performed. Wireless downloads from the implantable loop recorders were obtained intermittently for up to 2.5 years after placement. One male had an elevated cTnI level (210 ng/L), reduced ejection fraction (46%), and multiple episodes of supraventricular tachycardia and non-sustained ventricular tachycardia. Due to the abnormalities on ECG and echo, he was treated with metoprolol and lisinopril. Treatment was continued for nearly two years, until the animal had sudden cardiac death secondary to sustained ventricular fibrillation, which was confirmed by postmortem download of the loop recorder data and correlated with histologic evidence of cardiomyopathy. Implantable loop recorders greatly enhance the ability to diagnose and treat arrhythmias in primates and understand the mechanisms behind sudden cardiac deaths. Further studies are needed to establish cTnI, echocardiogram, and electrocardiogram reference ranges for this species, as well as appropriate treatment protocols.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Zoo and Wildlife Medicine
Journal of Zoo and Wildlife Medicine 农林科学-兽医学
CiteScore
1.70
自引率
14.30%
发文量
74
审稿时长
9-24 weeks
期刊介绍: The Journal of Zoo and Wildlife Medicine (JZWM) is considered one of the major sources of information on the biology and veterinary aspects in the field. It stems from the founding premise of AAZV to share zoo animal medicine experiences. The Journal evolved from the long history of members producing case reports and the increased publication of free-ranging wildlife papers. The Journal accepts manuscripts of original research findings, case reports in the field of veterinary medicine dealing with captive and free-ranging wild animals, brief communications regarding clinical or research observations that may warrant publication. It also publishes and encourages submission of relevant editorials, reviews, special reports, clinical challenges, abstracts of selected articles and book reviews. The Journal is published quarterly, is peer reviewed, is indexed by the major abstracting services, and is international in scope and distribution. Areas of interest include clinical medicine, surgery, anatomy, radiology, physiology, reproduction, nutrition, parasitology, microbiology, immunology, pathology (including infectious diseases and clinical pathology), toxicology, pharmacology, and epidemiology.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信