{"title":"周期长度交替的窄性复杂心动过速","authors":"Swasthi S. Kumar MD, Sudipta Mondal MD, DM, Jyothi Vijay MD, DM, Narayanan Namboodiri MD, DM","doi":"10.1016/j.jelectrocard.2025.153898","DOIUrl":null,"url":null,"abstract":"<div><div>An elderly lady without any comorbidities, presented with paroxysmal palpitations and was documented to have an adenosine-responsive narrow complex tachycardia (NCT). Baseline electrocardiogram (ECG) showed normal sinus rhythm with no preexcitation. Tachycardia ECG showed a regularly irregular short RP NCT at the rate of around 150/min with alternating cycle lengths of 320 ms and 360 ms.</div><div>What is the likely diagnosis?</div></div>","PeriodicalId":15606,"journal":{"name":"Journal of electrocardiology","volume":"90 ","pages":"Article 153898"},"PeriodicalIF":1.3000,"publicationDate":"2025-02-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Narrow complex tachycardia with cycle length alternans\",\"authors\":\"Swasthi S. Kumar MD, Sudipta Mondal MD, DM, Jyothi Vijay MD, DM, Narayanan Namboodiri MD, DM\",\"doi\":\"10.1016/j.jelectrocard.2025.153898\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><div>An elderly lady without any comorbidities, presented with paroxysmal palpitations and was documented to have an adenosine-responsive narrow complex tachycardia (NCT). Baseline electrocardiogram (ECG) showed normal sinus rhythm with no preexcitation. Tachycardia ECG showed a regularly irregular short RP NCT at the rate of around 150/min with alternating cycle lengths of 320 ms and 360 ms.</div><div>What is the likely diagnosis?</div></div>\",\"PeriodicalId\":15606,\"journal\":{\"name\":\"Journal of electrocardiology\",\"volume\":\"90 \",\"pages\":\"Article 153898\"},\"PeriodicalIF\":1.3000,\"publicationDate\":\"2025-02-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of electrocardiology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0022073625000263\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of electrocardiology","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0022073625000263","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
Narrow complex tachycardia with cycle length alternans
An elderly lady without any comorbidities, presented with paroxysmal palpitations and was documented to have an adenosine-responsive narrow complex tachycardia (NCT). Baseline electrocardiogram (ECG) showed normal sinus rhythm with no preexcitation. Tachycardia ECG showed a regularly irregular short RP NCT at the rate of around 150/min with alternating cycle lengths of 320 ms and 360 ms.
期刊介绍:
The Journal of Electrocardiology is devoted exclusively to clinical and experimental studies of the electrical activities of the heart. It seeks to contribute significantly to the accuracy of diagnosis and prognosis and the effective treatment, prevention, or delay of heart disease. Editorial contents include electrocardiography, vectorcardiography, arrhythmias, membrane action potential, cardiac pacing, monitoring defibrillation, instrumentation, drug effects, and computer applications.