比较主观测量与客观视力评估。

T C Jenkins, W A Douthwaite
{"title":"比较主观测量与客观视力评估。","authors":"T C Jenkins,&nbsp;W A Douthwaite","doi":"10.1097/00006324-198812000-00007","DOIUrl":null,"url":null,"abstract":"<p><p>Visual acuity was estimated by making amplitude measurements of the transient visually evoked response (VER) wave to pattern reversal using check sizes of 5.5, 7.5, 8.5, and 9.5 min arc. As in previous studies the 5.5 min arc check produced a response which reflected the visual acuity of the high acuity subjects, but often failed to produce a VER wave at the low acuity end. The proposal is made that where the 5.5 min arc check produces an acceptable wave (amplitude greater than 1.5 microV) then the regression line for the 5.5 check can be used to predict visual acuity. Where the VER amplitude is below 1.5 microV for this small check size then a second recording must be made using the 9.5 min arc check and the visual acuity predicted from the 9.5 check regression line.</p>","PeriodicalId":7700,"journal":{"name":"American journal of optometry and physiological optics","volume":"65 12","pages":"957-61"},"PeriodicalIF":0.0000,"publicationDate":"1988-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1097/00006324-198812000-00007","citationCount":"19","resultStr":"{\"title\":\"An objective VER assessment of visual acuity compared with subjective measures.\",\"authors\":\"T C Jenkins,&nbsp;W A Douthwaite\",\"doi\":\"10.1097/00006324-198812000-00007\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Visual acuity was estimated by making amplitude measurements of the transient visually evoked response (VER) wave to pattern reversal using check sizes of 5.5, 7.5, 8.5, and 9.5 min arc. As in previous studies the 5.5 min arc check produced a response which reflected the visual acuity of the high acuity subjects, but often failed to produce a VER wave at the low acuity end. The proposal is made that where the 5.5 min arc check produces an acceptable wave (amplitude greater than 1.5 microV) then the regression line for the 5.5 check can be used to predict visual acuity. Where the VER amplitude is below 1.5 microV for this small check size then a second recording must be made using the 9.5 min arc check and the visual acuity predicted from the 9.5 check regression line.</p>\",\"PeriodicalId\":7700,\"journal\":{\"name\":\"American journal of optometry and physiological optics\",\"volume\":\"65 12\",\"pages\":\"957-61\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1988-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1097/00006324-198812000-00007\",\"citationCount\":\"19\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"American journal of optometry and physiological optics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1097/00006324-198812000-00007\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"American journal of optometry and physiological optics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1097/00006324-198812000-00007","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 19

摘要

通过测量瞬态视觉诱发反应(VER)波的振幅来估计视力,使用5.5,7.5,8.5和9.5 min弧的检查尺寸。在先前的研究中,5.5分钟弧线检查产生的反应反映了高视力受试者的视力,但在低视力端往往不能产生VER波。建议在5.5分钟弧度检查产生可接受的波(振幅大于1.5微伏)的地方,然后5.5检查的回复线可用于预测视力。对于这种小止回阀尺寸,如果VER振幅低于1.5微伏,则必须使用9.5分钟弧度止回阀和从9.5止回阀回复线预测的视力进行第二次记录。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
An objective VER assessment of visual acuity compared with subjective measures.

Visual acuity was estimated by making amplitude measurements of the transient visually evoked response (VER) wave to pattern reversal using check sizes of 5.5, 7.5, 8.5, and 9.5 min arc. As in previous studies the 5.5 min arc check produced a response which reflected the visual acuity of the high acuity subjects, but often failed to produce a VER wave at the low acuity end. The proposal is made that where the 5.5 min arc check produces an acceptable wave (amplitude greater than 1.5 microV) then the regression line for the 5.5 check can be used to predict visual acuity. Where the VER amplitude is below 1.5 microV for this small check size then a second recording must be made using the 9.5 min arc check and the visual acuity predicted from the 9.5 check regression line.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信