{"title":"小儿CT血管造影carekv图像质量评估:有效剂量减少50%以上的可行性研究","authors":"Chunmei Fan ,&nbsp;Runtong Lu ,&nbsp;Dilisaer Naisula ,&nbsp;Fei Bi ,&nbsp;Xin Liu ,&nbsp;Shui Wang ,&nbsp;Jihang Sun","doi":"10.1016/j.jrras.2025.101386","DOIUrl":null,"url":null,"abstract":"<div><h3>Objective</h3><div>To evaluate whether the application of CARE kV automatic tube voltage modulation technology can reduce the radiation dose required for CT angiography (CTA) in children rapidly, conveniently, and effectively while maintaining image quality.</div></div><div><h3>Methods</h3><div>57 pediatric abdominal CTA were enrolled in the study and control groups. The tube voltage was automatically modulated using CARE kV. Dose-saving optimization indices used for the study and control groups were 12 (preference for a lower tube voltage) and 3 (preference for a higher tube voltage), respectively. Tube voltage and effective dose (ED) were recorded for the two groups, and a multiple linear regression analysis was used to scrutinize factors influencing voltage selection and radiation dose. Two reviewers subjectively evaluated the image quality using a 5-point Likert scale (3 points: qualified; 5 points: best), and the contrast-to-noise ratio (CNR) was calculated.</div></div><div><h3>Results</h3><div>The most commonly selected tube voltage was 70 kV (36/57, 63.16%) and 100 kV (30/57, 52.63%) in the study and control groups, respectively (<em>p</em> &lt; 0.001). The ED of the study group was 1.58 ± 1.05 mSv, which was 57.07% lower than that in the control group (<em>p</em> &lt; 0.001). Both voltage selection and ED exhibited a negative correlation with the DI value. The small artery display ability of the two groups was 4.05 ± 0.64 and 4.11 ± 0.65 (<em>p</em> = 0.31). No statistically significant difference was found for the aortic CNR between the two groups (<em>p</em> = 0.15).</div></div><div><h3>Conclusion</h3><div>CARE kV is a rapid, convenient, and effective way to reduce the radiation dose in CTA by &gt;50% in children.</div></div>","PeriodicalId":16920,"journal":{"name":"Journal of Radiation Research and Applied Sciences","volume":"18 2","pages":"Article 101386"},"PeriodicalIF":1.7000,"publicationDate":"2025-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Image quality assessment of the CARE kV for pediatric CT angiography: A feasibility study of over 50% effective dose reduction\",\"authors\":\"Chunmei Fan ,&nbsp;Runtong Lu ,&nbsp;Dilisaer Naisula ,&nbsp;Fei Bi ,&nbsp;Xin Liu ,&nbsp;Shui Wang ,&nbsp;Jihang Sun\",\"doi\":\"10.1016/j.jrras.2025.101386\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Objective</h3><div>To evaluate whether the application of CARE kV automatic tube voltage modulation technology can reduce the radiation dose required for CT angiography (CTA) in children rapidly, conveniently, and effectively while maintaining image quality.</div></div><div><h3>Methods</h3><div>57 pediatric abdominal CTA were enrolled in the study and control groups. The tube voltage was automatically modulated using CARE kV. Dose-saving optimization indices used for the study and control groups were 12 (preference for a lower tube voltage) and 3 (preference for a higher tube voltage), respectively. Tube voltage and effective dose (ED) were recorded for the two groups, and a multiple linear regression analysis was used to scrutinize factors influencing voltage selection and radiation dose. Two reviewers subjectively evaluated the image quality using a 5-point Likert scale (3 points: qualified; 5 points: best), and the contrast-to-noise ratio (CNR) was calculated.</div></div><div><h3>Results</h3><div>The most commonly selected tube voltage was 70 kV (36/57, 63.16%) and 100 kV (30/57, 52.63%) in the study and control groups, respectively (<em>p</em> &lt; 0.001). The ED of the study group was 1.58 ± 1.05 mSv, which was 57.07% lower than that in the control group (<em>p</em> &lt; 0.001). Both voltage selection and ED exhibited a negative correlation with the DI value. The small artery display ability of the two groups was 4.05 ± 0.64 and 4.11 ± 0.65 (<em>p</em> = 0.31). No statistically significant difference was found for the aortic CNR between the two groups (<em>p</em> = 0.15).</div></div><div><h3>Conclusion</h3><div>CARE kV is a rapid, convenient, and effective way to reduce the radiation dose in CTA by &gt;50% in children.</div></div>\",\"PeriodicalId\":16920,\"journal\":{\"name\":\"Journal of Radiation Research and Applied Sciences\",\"volume\":\"18 2\",\"pages\":\"Article 101386\"},\"PeriodicalIF\":1.7000,\"publicationDate\":\"2025-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Radiation Research and Applied Sciences\",\"FirstCategoryId\":\"103\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S1687850725000986\",\"RegionNum\":4,\"RegionCategory\":\"综合性期刊\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"MULTIDISCIPLINARY SCIENCES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Radiation Research and Applied Sciences","FirstCategoryId":"103","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1687850725000986","RegionNum":4,"RegionCategory":"综合性期刊","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MULTIDISCIPLINARY SCIENCES","Score":null,"Total":0}
引用次数: 0

摘要

目的评价应用CARE kV自动管电压调制技术能否在保持图像质量的前提下,快速、方便、有效地降低儿童CT血管造影(CTA)所需辐射剂量。方法将57例小儿腹部CTA分为研究组和对照组。管电压采用CARE kV自动调制。实验组和对照组的剂量节约优化指标分别为12项(低管电压优先)和3项(高管电压优先)。记录两组的管电压和有效剂量(ED),采用多元线性回归分析影响电压选择和辐射剂量的因素。两名评论者使用5分李克特量表主观评价图像质量(3分:合格;5分:最佳),计算噪声对比比(CNR)。结果研究组和对照组最常选择的管电压分别为70 kV(36/57, 63.16%)和100 kV (30/57, 52.63%) (p <;0.001)。研究组ED为1.58±1.05 mSv,较对照组降低57.07% (p <;0.001)。电压选择和ED均与DI值呈负相关。两组小动脉显示能力分别为4.05±0.64和4.11±0.65 (p = 0.31)。两组患者主动脉CNR差异无统计学意义(p = 0.15)。结论carekv是一种快速、方便、有效的方法,可使儿童CTA放射剂量降低50%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Image quality assessment of the CARE kV for pediatric CT angiography: A feasibility study of over 50% effective dose reduction

Objective

To evaluate whether the application of CARE kV automatic tube voltage modulation technology can reduce the radiation dose required for CT angiography (CTA) in children rapidly, conveniently, and effectively while maintaining image quality.

Methods

57 pediatric abdominal CTA were enrolled in the study and control groups. The tube voltage was automatically modulated using CARE kV. Dose-saving optimization indices used for the study and control groups were 12 (preference for a lower tube voltage) and 3 (preference for a higher tube voltage), respectively. Tube voltage and effective dose (ED) were recorded for the two groups, and a multiple linear regression analysis was used to scrutinize factors influencing voltage selection and radiation dose. Two reviewers subjectively evaluated the image quality using a 5-point Likert scale (3 points: qualified; 5 points: best), and the contrast-to-noise ratio (CNR) was calculated.

Results

The most commonly selected tube voltage was 70 kV (36/57, 63.16%) and 100 kV (30/57, 52.63%) in the study and control groups, respectively (p < 0.001). The ED of the study group was 1.58 ± 1.05 mSv, which was 57.07% lower than that in the control group (p < 0.001). Both voltage selection and ED exhibited a negative correlation with the DI value. The small artery display ability of the two groups was 4.05 ± 0.64 and 4.11 ± 0.65 (p = 0.31). No statistically significant difference was found for the aortic CNR between the two groups (p = 0.15).

Conclusion

CARE kV is a rapid, convenient, and effective way to reduce the radiation dose in CTA by >50% in children.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
5.90%
发文量
130
审稿时长
16 weeks
期刊介绍: Journal of Radiation Research and Applied Sciences provides a high quality medium for the publication of substantial, original and scientific and technological papers on the development and applications of nuclear, radiation and isotopes in biology, medicine, drugs, biochemistry, microbiology, agriculture, entomology, food technology, chemistry, physics, solid states, engineering, environmental and applied sciences.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信