用于同时检测脂联素和瘦素的多路激光转录石墨烯免疫传感器:早期胰岛素抵抗诊断的护理点解决方案

IF 6.5 Q1 BIOTECHNOLOGY & APPLIED MICROBIOLOGY
Lavita Nuraviana Rizalputri , José Ilton de Oliveira Filho , Saptami Suresh Shetty , Eckaard le Roux , Abdullah Bukhamsin , Bandar Alshehri , Veerappan Mani , Khaled Nabil Salama
{"title":"用于同时检测脂联素和瘦素的多路激光转录石墨烯免疫传感器:早期胰岛素抵抗诊断的护理点解决方案","authors":"Lavita Nuraviana Rizalputri ,&nbsp;José Ilton de Oliveira Filho ,&nbsp;Saptami Suresh Shetty ,&nbsp;Eckaard le Roux ,&nbsp;Abdullah Bukhamsin ,&nbsp;Bandar Alshehri ,&nbsp;Veerappan Mani ,&nbsp;Khaled Nabil Salama","doi":"10.1016/j.snr.2025.100306","DOIUrl":null,"url":null,"abstract":"<div><div>The increasing prevalence of insulin resistance (IR) highlights the importance of early diagnosis and timely medical intervention. The ratio of adiponectin to leptin proteins (A/L) is believed to be a key indicator of IR, but the lack of adequate ways of tracking it prevents its clinical utilization. To that end, we have developed a laser-scribed graphene (LSG) based immunosensor capable of detecting adiponectin and leptin simultaneously. The sensors are decorated with gold nanostructure (AuNS) that are bio-functionalized with adiponectin and leptin antibodies via EDC/NHS covalent chemistry. We demonstrate that the immunosensor is suitable for clinical utilization, with a detection limit of 0.59 μg/mL for adiponectin and 0.18 ng/mL for leptin. Furthermore, the multiplexed nature of the assay allows for IR assessments at reduced sample volume whilst not compromising accuracy. Lastly, we validate the applicability of the immunosensor for point-of-care (PoC) settings by integrating with a customized miniaturized potentiostat connected to a smartphone application. The resulting device can be used for the facile quantification of A/L at clinically relevant accuracy, facilitating faster IR assessment relative to conventional methods that rely on independent measurements of the two biomarkers.</div></div>","PeriodicalId":426,"journal":{"name":"Sensors and Actuators Reports","volume":"9 ","pages":"Article 100306"},"PeriodicalIF":6.5000,"publicationDate":"2025-02-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A multiplexed laser-scribed graphene immunosensor for simultaneous detection of adiponectin and leptin: A point-of-care solution for early insulin resistance diagnosis\",\"authors\":\"Lavita Nuraviana Rizalputri ,&nbsp;José Ilton de Oliveira Filho ,&nbsp;Saptami Suresh Shetty ,&nbsp;Eckaard le Roux ,&nbsp;Abdullah Bukhamsin ,&nbsp;Bandar Alshehri ,&nbsp;Veerappan Mani ,&nbsp;Khaled Nabil Salama\",\"doi\":\"10.1016/j.snr.2025.100306\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><div>The increasing prevalence of insulin resistance (IR) highlights the importance of early diagnosis and timely medical intervention. The ratio of adiponectin to leptin proteins (A/L) is believed to be a key indicator of IR, but the lack of adequate ways of tracking it prevents its clinical utilization. To that end, we have developed a laser-scribed graphene (LSG) based immunosensor capable of detecting adiponectin and leptin simultaneously. The sensors are decorated with gold nanostructure (AuNS) that are bio-functionalized with adiponectin and leptin antibodies via EDC/NHS covalent chemistry. We demonstrate that the immunosensor is suitable for clinical utilization, with a detection limit of 0.59 μg/mL for adiponectin and 0.18 ng/mL for leptin. Furthermore, the multiplexed nature of the assay allows for IR assessments at reduced sample volume whilst not compromising accuracy. Lastly, we validate the applicability of the immunosensor for point-of-care (PoC) settings by integrating with a customized miniaturized potentiostat connected to a smartphone application. The resulting device can be used for the facile quantification of A/L at clinically relevant accuracy, facilitating faster IR assessment relative to conventional methods that rely on independent measurements of the two biomarkers.</div></div>\",\"PeriodicalId\":426,\"journal\":{\"name\":\"Sensors and Actuators Reports\",\"volume\":\"9 \",\"pages\":\"Article 100306\"},\"PeriodicalIF\":6.5000,\"publicationDate\":\"2025-02-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Sensors and Actuators Reports\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2666053925000256\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"BIOTECHNOLOGY & APPLIED MICROBIOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Sensors and Actuators Reports","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2666053925000256","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"BIOTECHNOLOGY & APPLIED MICROBIOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

胰岛素抵抗(IR)的日益流行突出了早期诊断和及时医疗干预的重要性。脂联素与瘦素蛋白的比值(A/L)被认为是IR的关键指标,但缺乏足够的跟踪方法阻碍了其临床应用。为此,我们开发了一种基于激光刻写石墨烯(LSG)的免疫传感器,能够同时检测脂联素和瘦素。这些传感器用金纳米结构(AuNS)装饰,通过EDC/NHS共价化学将其与脂联素和瘦素抗体进行生物功能化。结果表明,该免疫传感器适合临床应用,对脂联素和瘦素的检出限分别为0.59 μg/mL和0.18 ng/mL。此外,该分析的多路性质允许在减少样本量的同时不影响准确性的情况下进行IR评估。最后,我们通过集成连接到智能手机应用程序的定制小型化电位器,验证了免疫传感器在护理点(PoC)设置中的适用性。由此产生的设备可用于临床相关精度的A/L简便定量,相对于依赖于两种生物标志物独立测量的传统方法,可促进更快的IR评估。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

A multiplexed laser-scribed graphene immunosensor for simultaneous detection of adiponectin and leptin: A point-of-care solution for early insulin resistance diagnosis

A multiplexed laser-scribed graphene immunosensor for simultaneous detection of adiponectin and leptin: A point-of-care solution for early insulin resistance diagnosis
The increasing prevalence of insulin resistance (IR) highlights the importance of early diagnosis and timely medical intervention. The ratio of adiponectin to leptin proteins (A/L) is believed to be a key indicator of IR, but the lack of adequate ways of tracking it prevents its clinical utilization. To that end, we have developed a laser-scribed graphene (LSG) based immunosensor capable of detecting adiponectin and leptin simultaneously. The sensors are decorated with gold nanostructure (AuNS) that are bio-functionalized with adiponectin and leptin antibodies via EDC/NHS covalent chemistry. We demonstrate that the immunosensor is suitable for clinical utilization, with a detection limit of 0.59 μg/mL for adiponectin and 0.18 ng/mL for leptin. Furthermore, the multiplexed nature of the assay allows for IR assessments at reduced sample volume whilst not compromising accuracy. Lastly, we validate the applicability of the immunosensor for point-of-care (PoC) settings by integrating with a customized miniaturized potentiostat connected to a smartphone application. The resulting device can be used for the facile quantification of A/L at clinically relevant accuracy, facilitating faster IR assessment relative to conventional methods that rely on independent measurements of the two biomarkers.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
9.60
自引率
0.00%
发文量
60
审稿时长
49 days
期刊介绍: Sensors and Actuators Reports is a peer-reviewed open access journal launched out from the Sensors and Actuators journal family. Sensors and Actuators Reports is dedicated to publishing new and original works in the field of all type of sensors and actuators, including bio-, chemical-, physical-, and nano- sensors and actuators, which demonstrates significant progress beyond the current state of the art. The journal regularly publishes original research papers, reviews, and short communications. For research papers and short communications, the journal aims to publish the new and original work supported by experimental results and as such purely theoretical works are not accepted.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信