联合气相色谱/电子俘获化学电离质谱法测定脑脊液和血浆中的苯乙酸。

K F Faull, N Pascoe, K A Greene, J F Maddaluno, J Lunde, R J King
{"title":"联合气相色谱/电子俘获化学电离质谱法测定脑脊液和血浆中的苯乙酸。","authors":"K F Faull,&nbsp;N Pascoe,&nbsp;K A Greene,&nbsp;J F Maddaluno,&nbsp;J Lunde,&nbsp;R J King","doi":"10.1002/bms.1200170310","DOIUrl":null,"url":null,"abstract":"<p><p>Details are presented of an ultra-sensitive gas chromatographic/mass spectrometric assay for phenylacetic acid in plasma and cerebrospinal fluid based on measurements of the relative intensities of the carboxylate anions, derived from the penta- and tetrafluorobenzyl esters under electron capture chemical ionization conditions, of unlabeled and a (13C2)-labeled internal standard. The limits of detection for the penta- and tetrafluorobenzyl esters are 0.85 and 4.0 pg respectively, and the assay is capable of measuring phenylacetic acid concentrations in samples as small as 20 microliter of CSF and plasma. The penta- and tetrafluorobenzyl esters are chromatographically separated on the gas chromatograph column, which allows for their co-injection and independent measurement from the same chromatogram.</p>","PeriodicalId":8924,"journal":{"name":"Biomedical & environmental mass spectrometry","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"1988-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1002/bms.1200170310","citationCount":"9","resultStr":"{\"title\":\"Measurement of phenylacetic acid in cerebrospinal fluid and plasma using combined gas chromatography/electron capture chemical ionization mass spectrometry.\",\"authors\":\"K F Faull,&nbsp;N Pascoe,&nbsp;K A Greene,&nbsp;J F Maddaluno,&nbsp;J Lunde,&nbsp;R J King\",\"doi\":\"10.1002/bms.1200170310\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Details are presented of an ultra-sensitive gas chromatographic/mass spectrometric assay for phenylacetic acid in plasma and cerebrospinal fluid based on measurements of the relative intensities of the carboxylate anions, derived from the penta- and tetrafluorobenzyl esters under electron capture chemical ionization conditions, of unlabeled and a (13C2)-labeled internal standard. The limits of detection for the penta- and tetrafluorobenzyl esters are 0.85 and 4.0 pg respectively, and the assay is capable of measuring phenylacetic acid concentrations in samples as small as 20 microliter of CSF and plasma. The penta- and tetrafluorobenzyl esters are chromatographically separated on the gas chromatograph column, which allows for their co-injection and independent measurement from the same chromatogram.</p>\",\"PeriodicalId\":8924,\"journal\":{\"name\":\"Biomedical & environmental mass spectrometry\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1988-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1002/bms.1200170310\",\"citationCount\":\"9\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Biomedical & environmental mass spectrometry\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1002/bms.1200170310\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biomedical & environmental mass spectrometry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1002/bms.1200170310","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 9

摘要

详细介绍了一种超灵敏气相色谱/质谱法测定血浆和脑脊液中苯乙酸的方法,该方法基于在电子捕获化学电离条件下从五氟和四氟苯酯中提取的羧酸阴离子的相对强度的测量,这些阴离子来自未标记和(13C2)标记的内标。五氟苯酯和四氟苯酯的检出限分别为0.85和4.0 pg,该试验能够测量小至20微升脑脊液和血浆样品中的苯乙酸浓度。五氟苯酯和四氟苯酯在气相色谱柱上进行色谱分离,这允许它们共进样和从同一色谱图独立测量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Measurement of phenylacetic acid in cerebrospinal fluid and plasma using combined gas chromatography/electron capture chemical ionization mass spectrometry.

Details are presented of an ultra-sensitive gas chromatographic/mass spectrometric assay for phenylacetic acid in plasma and cerebrospinal fluid based on measurements of the relative intensities of the carboxylate anions, derived from the penta- and tetrafluorobenzyl esters under electron capture chemical ionization conditions, of unlabeled and a (13C2)-labeled internal standard. The limits of detection for the penta- and tetrafluorobenzyl esters are 0.85 and 4.0 pg respectively, and the assay is capable of measuring phenylacetic acid concentrations in samples as small as 20 microliter of CSF and plasma. The penta- and tetrafluorobenzyl esters are chromatographically separated on the gas chromatograph column, which allows for their co-injection and independent measurement from the same chromatogram.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信