利用新型光诱导多重电离质谱仪提高挥发性有机化合物检测灵敏度

IF 6.7 1区 化学 Q1 CHEMISTRY, ANALYTICAL
Xun Bao, Qu Liang, Qiangling Zhang, Xue Zou, Chaoqun Huang, Chengyin Shen, Yannan Chu
{"title":"利用新型光诱导多重电离质谱仪提高挥发性有机化合物检测灵敏度","authors":"Xun Bao, Qu Liang, Qiangling Zhang, Xue Zou, Chaoqun Huang, Chengyin Shen, Yannan Chu","doi":"10.1021/acs.analchem.4c05873","DOIUrl":null,"url":null,"abstract":"Proton transfer reaction mass spectrometry (PTR-MS) is an important online monitoring technique for volatile organic compounds (VOCs). VOCs have the characteristics of many types, rapid change, and low concentration. Enhancing the detection sensitivity and expanding the detection range of VOCs have been key challenges in PTR-MS research. In this work, we have developed and characterized a novel photoinduced multiple ionizations (PMI) source, which consists of four direct current (DC) vacuum ultraviolet Kr lamps and a V-shaped focusing quadrupole ion funnel (FQ-IF) drift tube. The novel PMI source has four ionization processes: proton transfer reaction, charge transfer reaction, single photon ionization, and photoelectron impact ionization. It is capable of detecting VOCs detectable by conventional PTR-MS via the PTR, as well as VOCs (carbon disulfide and acetylene) that are difficult to detect by conventional PTR-MS through other ionization processes, thus effectively expanding the detection range. In further comparative experiments, the improvements in sensitivity for the PMI-MS in FQ-IF mode range from 122.5 to 647.7 times compared to the PTR-MS in DC mode (conventional PTR-MS) for 12 test VOCs. Notably, the sensitivities of four BTEXs in 12 VOCs were more than 10,000 cps/ppb. Moreover, compared with PTR-MS in DC mode, the LOD of PMI-MS in FQ-IF mode for 12 test VOCs increased by 26–128.6 times. PMI-MS not only expands the detection range but also improves the sensitivity by 2 orders of magnitude, which would provide an important tool for the detection of ultratrace VOCs.","PeriodicalId":27,"journal":{"name":"Analytical Chemistry","volume":"2 1","pages":""},"PeriodicalIF":6.7000,"publicationDate":"2025-02-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Increased Sensitivity in VOC Detection by Using a Novel Photoinduced Multiple Ionization Mass Spectrometry\",\"authors\":\"Xun Bao, Qu Liang, Qiangling Zhang, Xue Zou, Chaoqun Huang, Chengyin Shen, Yannan Chu\",\"doi\":\"10.1021/acs.analchem.4c05873\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Proton transfer reaction mass spectrometry (PTR-MS) is an important online monitoring technique for volatile organic compounds (VOCs). VOCs have the characteristics of many types, rapid change, and low concentration. Enhancing the detection sensitivity and expanding the detection range of VOCs have been key challenges in PTR-MS research. In this work, we have developed and characterized a novel photoinduced multiple ionizations (PMI) source, which consists of four direct current (DC) vacuum ultraviolet Kr lamps and a V-shaped focusing quadrupole ion funnel (FQ-IF) drift tube. The novel PMI source has four ionization processes: proton transfer reaction, charge transfer reaction, single photon ionization, and photoelectron impact ionization. It is capable of detecting VOCs detectable by conventional PTR-MS via the PTR, as well as VOCs (carbon disulfide and acetylene) that are difficult to detect by conventional PTR-MS through other ionization processes, thus effectively expanding the detection range. In further comparative experiments, the improvements in sensitivity for the PMI-MS in FQ-IF mode range from 122.5 to 647.7 times compared to the PTR-MS in DC mode (conventional PTR-MS) for 12 test VOCs. Notably, the sensitivities of four BTEXs in 12 VOCs were more than 10,000 cps/ppb. Moreover, compared with PTR-MS in DC mode, the LOD of PMI-MS in FQ-IF mode for 12 test VOCs increased by 26–128.6 times. PMI-MS not only expands the detection range but also improves the sensitivity by 2 orders of magnitude, which would provide an important tool for the detection of ultratrace VOCs.\",\"PeriodicalId\":27,\"journal\":{\"name\":\"Analytical Chemistry\",\"volume\":\"2 1\",\"pages\":\"\"},\"PeriodicalIF\":6.7000,\"publicationDate\":\"2025-02-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Analytical Chemistry\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://doi.org/10.1021/acs.analchem.4c05873\",\"RegionNum\":1,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analytical Chemistry","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1021/acs.analchem.4c05873","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

摘要

本文章由计算机程序翻译,如有差异,请以英文原文为准。

Increased Sensitivity in VOC Detection by Using a Novel Photoinduced Multiple Ionization Mass Spectrometry

Increased Sensitivity in VOC Detection by Using a Novel Photoinduced Multiple Ionization Mass Spectrometry
Proton transfer reaction mass spectrometry (PTR-MS) is an important online monitoring technique for volatile organic compounds (VOCs). VOCs have the characteristics of many types, rapid change, and low concentration. Enhancing the detection sensitivity and expanding the detection range of VOCs have been key challenges in PTR-MS research. In this work, we have developed and characterized a novel photoinduced multiple ionizations (PMI) source, which consists of four direct current (DC) vacuum ultraviolet Kr lamps and a V-shaped focusing quadrupole ion funnel (FQ-IF) drift tube. The novel PMI source has four ionization processes: proton transfer reaction, charge transfer reaction, single photon ionization, and photoelectron impact ionization. It is capable of detecting VOCs detectable by conventional PTR-MS via the PTR, as well as VOCs (carbon disulfide and acetylene) that are difficult to detect by conventional PTR-MS through other ionization processes, thus effectively expanding the detection range. In further comparative experiments, the improvements in sensitivity for the PMI-MS in FQ-IF mode range from 122.5 to 647.7 times compared to the PTR-MS in DC mode (conventional PTR-MS) for 12 test VOCs. Notably, the sensitivities of four BTEXs in 12 VOCs were more than 10,000 cps/ppb. Moreover, compared with PTR-MS in DC mode, the LOD of PMI-MS in FQ-IF mode for 12 test VOCs increased by 26–128.6 times. PMI-MS not only expands the detection range but also improves the sensitivity by 2 orders of magnitude, which would provide an important tool for the detection of ultratrace VOCs.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Analytical Chemistry
Analytical Chemistry 化学-分析化学
CiteScore
12.10
自引率
12.20%
发文量
1949
审稿时长
1.4 months
期刊介绍: Analytical Chemistry, a peer-reviewed research journal, focuses on disseminating new and original knowledge across all branches of analytical chemistry. Fundamental articles may explore general principles of chemical measurement science and need not directly address existing or potential analytical methodology. They can be entirely theoretical or report experimental results. Contributions may cover various phases of analytical operations, including sampling, bioanalysis, electrochemistry, mass spectrometry, microscale and nanoscale systems, environmental analysis, separations, spectroscopy, chemical reactions and selectivity, instrumentation, imaging, surface analysis, and data processing. Papers discussing known analytical methods should present a significant, original application of the method, a notable improvement, or results on an important analyte.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信