使用TrEnDi改进的LC-MS检测阿片类药物、安非他命和致幻剂。

IF 2.7 2区 化学 Q2 BIOCHEMICAL RESEARCH METHODS
Christian A Rosales, Noah A Lepinsky, Wondewossen Gebeyehu, Karl V Wasslen, Fraser Colquhoun, Benjamin B Warnes, Jasmine Chihabi, Jeffrey M Manthorpe, Jeffrey C Smith
{"title":"使用TrEnDi改进的LC-MS检测阿片类药物、安非他命和致幻剂。","authors":"Christian A Rosales, Noah A Lepinsky, Wondewossen Gebeyehu, Karl V Wasslen, Fraser Colquhoun, Benjamin B Warnes, Jasmine Chihabi, Jeffrey M Manthorpe, Jeffrey C Smith","doi":"10.1021/jasms.4c00382","DOIUrl":null,"url":null,"abstract":"<p><p>Substances of misuse are becoming increasingly difficult to analyze as unique methods of smuggling are adopted and due to the rapid emergence of new psychoactive substances, increasing the pool of compounds to characterize and identify. Technologies such as gas chromatography and liquid chromatography coupled to mass spectrometry (MS) represent the gold standard for accurate and robust analysis, with on-site ambient- and portable-MS systems providing rapid methods of drug screening and testing. For many samples containing residual analyte quantities, methods to improve sensitivity through chemical derivatization are critical for accurate determination. Herein, we demonstrate for the first time the use of trimethylation enhancement using diazomethane (TrEnDi) to improve the MS-based sensitivity of 13 different drugs of misuse. All analytes were successfully permethylated, with 11 demonstrating improved analytical characteristics from TrEnDi with MS sensitivity enhancements ranging from 1.2-fold to as high as 24.2-fold in the case of psilocybin, as well as increases in reversed-phase chromatographic retention for most species. Derivatization using <sup>13</sup>C-isotopically labeled TrEnDi reagents were used to successfully resolve isobaric interference issues between three pairs of controlled substances. By using an unconventional aprotic solvent system for electrospray ionization, the benefit of a fixed-permanent positive charge was highlighted as TrEnDi-modified amphetamine was easily measured while unmodified was not detected. Finally, TrEnDi was employed to boost the sensitivity of morphine in a real urine matrix. Our results demonstrate a percent recovery of 103.1% and a sensitivity enhancement of 2.4-fold, demonstrating the versatility and applicability of TrEnDi to pre-existing analytical workflows for trace analysis.</p>","PeriodicalId":672,"journal":{"name":"Journal of the American Society for Mass Spectrometry","volume":" ","pages":"514-523"},"PeriodicalIF":2.7000,"publicationDate":"2025-03-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Improved LC-MS Detection of Opioids, Amphetamines, and Psychedelics Using TrEnDi.\",\"authors\":\"Christian A Rosales, Noah A Lepinsky, Wondewossen Gebeyehu, Karl V Wasslen, Fraser Colquhoun, Benjamin B Warnes, Jasmine Chihabi, Jeffrey M Manthorpe, Jeffrey C Smith\",\"doi\":\"10.1021/jasms.4c00382\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Substances of misuse are becoming increasingly difficult to analyze as unique methods of smuggling are adopted and due to the rapid emergence of new psychoactive substances, increasing the pool of compounds to characterize and identify. Technologies such as gas chromatography and liquid chromatography coupled to mass spectrometry (MS) represent the gold standard for accurate and robust analysis, with on-site ambient- and portable-MS systems providing rapid methods of drug screening and testing. For many samples containing residual analyte quantities, methods to improve sensitivity through chemical derivatization are critical for accurate determination. Herein, we demonstrate for the first time the use of trimethylation enhancement using diazomethane (TrEnDi) to improve the MS-based sensitivity of 13 different drugs of misuse. All analytes were successfully permethylated, with 11 demonstrating improved analytical characteristics from TrEnDi with MS sensitivity enhancements ranging from 1.2-fold to as high as 24.2-fold in the case of psilocybin, as well as increases in reversed-phase chromatographic retention for most species. Derivatization using <sup>13</sup>C-isotopically labeled TrEnDi reagents were used to successfully resolve isobaric interference issues between three pairs of controlled substances. By using an unconventional aprotic solvent system for electrospray ionization, the benefit of a fixed-permanent positive charge was highlighted as TrEnDi-modified amphetamine was easily measured while unmodified was not detected. Finally, TrEnDi was employed to boost the sensitivity of morphine in a real urine matrix. Our results demonstrate a percent recovery of 103.1% and a sensitivity enhancement of 2.4-fold, demonstrating the versatility and applicability of TrEnDi to pre-existing analytical workflows for trace analysis.</p>\",\"PeriodicalId\":672,\"journal\":{\"name\":\"Journal of the American Society for Mass Spectrometry\",\"volume\":\" \",\"pages\":\"514-523\"},\"PeriodicalIF\":2.7000,\"publicationDate\":\"2025-03-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of the American Society for Mass Spectrometry\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://doi.org/10.1021/jasms.4c00382\",\"RegionNum\":2,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2025/2/3 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"BIOCHEMICAL RESEARCH METHODS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the American Society for Mass Spectrometry","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1021/jasms.4c00382","RegionNum":2,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/2/3 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0

摘要

由于采用了独特的走私方法,而且由于新的精神活性物质迅速出现,需要鉴定和查明的化合物种类增加,滥用药物的分析变得越来越困难。气相色谱和液相色谱耦合质谱(MS)等技术代表了准确和可靠分析的金标准,现场环境和便携式质谱系统提供了快速的药物筛选和测试方法。对于许多含有残留分析物量的样品,通过化学衍生化提高灵敏度的方法对于准确测定至关重要。在此,我们首次展示了使用重氮甲烷(TrEnDi)的三甲基化增强来提高13种不同药物滥用的MS-based敏感性。所有分析物都成功过甲基化,其中11种显示TrEnDi的分析特征得到改善,MS灵敏度增强,在裸盖菇素的情况下从1.2倍到高达24.2倍,并且大多数物种的反相色谱保留率增加。采用13c同位素标记的TrEnDi试剂衍生化,成功解决了三对受控物质之间的等压干扰问题。采用非常规的非质子溶剂体系进行电喷雾电离,由于trendi修饰的安非他明易于测量,而未修饰的安非他明则无法检测到,从而突出了固定永久正电荷的优点。最后,TrEnDi被用来提高吗啡在真实尿液基质中的敏感性。我们的结果表明,回收率为103.1%,灵敏度提高了2.4倍,证明了TrEnDi在已有的痕量分析工作流程中的通用性和适用性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Improved LC-MS Detection of Opioids, Amphetamines, and Psychedelics Using TrEnDi.

Substances of misuse are becoming increasingly difficult to analyze as unique methods of smuggling are adopted and due to the rapid emergence of new psychoactive substances, increasing the pool of compounds to characterize and identify. Technologies such as gas chromatography and liquid chromatography coupled to mass spectrometry (MS) represent the gold standard for accurate and robust analysis, with on-site ambient- and portable-MS systems providing rapid methods of drug screening and testing. For many samples containing residual analyte quantities, methods to improve sensitivity through chemical derivatization are critical for accurate determination. Herein, we demonstrate for the first time the use of trimethylation enhancement using diazomethane (TrEnDi) to improve the MS-based sensitivity of 13 different drugs of misuse. All analytes were successfully permethylated, with 11 demonstrating improved analytical characteristics from TrEnDi with MS sensitivity enhancements ranging from 1.2-fold to as high as 24.2-fold in the case of psilocybin, as well as increases in reversed-phase chromatographic retention for most species. Derivatization using 13C-isotopically labeled TrEnDi reagents were used to successfully resolve isobaric interference issues between three pairs of controlled substances. By using an unconventional aprotic solvent system for electrospray ionization, the benefit of a fixed-permanent positive charge was highlighted as TrEnDi-modified amphetamine was easily measured while unmodified was not detected. Finally, TrEnDi was employed to boost the sensitivity of morphine in a real urine matrix. Our results demonstrate a percent recovery of 103.1% and a sensitivity enhancement of 2.4-fold, demonstrating the versatility and applicability of TrEnDi to pre-existing analytical workflows for trace analysis.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
5.50
自引率
9.40%
发文量
257
审稿时长
1 months
期刊介绍: The Journal of the American Society for Mass Spectrometry presents research papers covering all aspects of mass spectrometry, incorporating coverage of fields of scientific inquiry in which mass spectrometry can play a role. Comprehensive in scope, the journal publishes papers on both fundamentals and applications of mass spectrometry. Fundamental subjects include instrumentation principles, design, and demonstration, structures and chemical properties of gas-phase ions, studies of thermodynamic properties, ion spectroscopy, chemical kinetics, mechanisms of ionization, theories of ion fragmentation, cluster ions, and potential energy surfaces. In addition to full papers, the journal offers Communications, Application Notes, and Accounts and Perspectives
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信