对数减去反演恢复。

IF 2.1 4区 医学 Q2 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Mark Bydder, Daniel M Cornfeld, Tracy R Melzer, Paul Condron, Gil Newburn, Eryn E Kwon, Maryam Tayebi, Miriam Scadeng, Samantha J Holdsworth, Graeme M Bydder
{"title":"对数减去反演恢复。","authors":"Mark Bydder, Daniel M Cornfeld, Tracy R Melzer, Paul Condron, Gil Newburn, Eryn E Kwon, Maryam Tayebi, Miriam Scadeng, Samantha J Holdsworth, Graeme M Bydder","doi":"10.1016/j.mri.2025.110328","DOIUrl":null,"url":null,"abstract":"<p><p>Magnetic resonance imaging (MRI) techniques have recently been developed for obtaining high T<sub>1</sub> contrast images using inversion recovery (IR) images at two inversion times (TIs) rather than a single TI. They use simple mathematical operations - multiplication, addition, subtraction, division - to create images not attainable by conventional IR. The present study describes a novel two-point IR technique formed by the subtraction of log images. Results show it has a near-linear response to T<sub>1</sub> between the nullpoints that peaks sharply at the nullpoints. This produces a bright isoT<sub>1</sub> contour at interfaces between tissues where partial volume mixing generates specific T<sub>1</sub>s. This can provide anatomical information in areas where the signal is not well-differentiated on conventional images.</p>","PeriodicalId":18165,"journal":{"name":"Magnetic resonance imaging","volume":"117 ","pages":"110328"},"PeriodicalIF":2.1000,"publicationDate":"2025-01-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Log subtracted inversion recovery.\",\"authors\":\"Mark Bydder, Daniel M Cornfeld, Tracy R Melzer, Paul Condron, Gil Newburn, Eryn E Kwon, Maryam Tayebi, Miriam Scadeng, Samantha J Holdsworth, Graeme M Bydder\",\"doi\":\"10.1016/j.mri.2025.110328\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Magnetic resonance imaging (MRI) techniques have recently been developed for obtaining high T<sub>1</sub> contrast images using inversion recovery (IR) images at two inversion times (TIs) rather than a single TI. They use simple mathematical operations - multiplication, addition, subtraction, division - to create images not attainable by conventional IR. The present study describes a novel two-point IR technique formed by the subtraction of log images. Results show it has a near-linear response to T<sub>1</sub> between the nullpoints that peaks sharply at the nullpoints. This produces a bright isoT<sub>1</sub> contour at interfaces between tissues where partial volume mixing generates specific T<sub>1</sub>s. This can provide anatomical information in areas where the signal is not well-differentiated on conventional images.</p>\",\"PeriodicalId\":18165,\"journal\":{\"name\":\"Magnetic resonance imaging\",\"volume\":\"117 \",\"pages\":\"110328\"},\"PeriodicalIF\":2.1000,\"publicationDate\":\"2025-01-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Magnetic resonance imaging\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1016/j.mri.2025.110328\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Magnetic resonance imaging","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1016/j.mri.2025.110328","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

摘要

磁共振成像(MRI)技术最近得到了发展,利用两次反转时间(TI)的反转恢复(IR)图像获得高T1对比度图像,而不是单一的TI。他们使用简单的数学运算——乘法、加法、减法、除法——来创建传统红外无法实现的图像。本研究描述了一种新的两点红外技术,该技术是由对数图像相减形成的。结果表明,它对零点之间的T1具有近似线性的响应,在零点处达到峰值。这在组织之间的界面产生明亮的isoT1轮廓,其中部分体积混合产生特定的t1。这可以在传统图像上信号不能很好区分的区域提供解剖信息。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Log subtracted inversion recovery.

Magnetic resonance imaging (MRI) techniques have recently been developed for obtaining high T1 contrast images using inversion recovery (IR) images at two inversion times (TIs) rather than a single TI. They use simple mathematical operations - multiplication, addition, subtraction, division - to create images not attainable by conventional IR. The present study describes a novel two-point IR technique formed by the subtraction of log images. Results show it has a near-linear response to T1 between the nullpoints that peaks sharply at the nullpoints. This produces a bright isoT1 contour at interfaces between tissues where partial volume mixing generates specific T1s. This can provide anatomical information in areas where the signal is not well-differentiated on conventional images.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Magnetic resonance imaging
Magnetic resonance imaging 医学-核医学
CiteScore
4.70
自引率
4.00%
发文量
194
审稿时长
83 days
期刊介绍: Magnetic Resonance Imaging (MRI) is the first international multidisciplinary journal encompassing physical, life, and clinical science investigations as they relate to the development and use of magnetic resonance imaging. MRI is dedicated to both basic research, technological innovation and applications, providing a single forum for communication among radiologists, physicists, chemists, biochemists, biologists, engineers, internists, pathologists, physiologists, computer scientists, and mathematicians.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信