{"title":"在机器人辅助的外翻畸形全膝关节置换术中实现了安全的冠状位对齐和良好的短期效果。","authors":"Pietro Gregori, Christos Koutserimpas, Vasileios Giovanoulis, Cécile Batailler, Elvire Servien, Sébastien Lustig","doi":"10.1002/ksa.12585","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Functional alignment (FA) in total knee arthroplasty (TKA) prioritizes soft tissue balancing and anatomical restoration without systematic correction to neutral alignment. Most studies have focused on varus deformity, with little evidence available about FA in valgus deformity. The hypothesis of the present study was that FA in robotic-assisted TKA for valgus deformity would demonstrate correction of the coronal alignment and yield satisfactory short-term outcomes.</p><p><strong>Methods: </strong>This retrospective study included 58 patients with valgus coronal alignment (hip-knee-angle [HKA] ≥ 183°) who underwent robotic-assisted TKA using the FA technique with a minimum of 1-year follow-up. Outcomes were assessed through the Knee Society Score (KSS), Oxford Knee Score (OKS), Forgotten Joint Score (FJS) and radiographic measurements of alignment and phenotypes. Complication and revision rates were also analyzed.</p><p><strong>Results: </strong>The cohort included 39 females and 19 males with a median age of 70. Post-operatively, 86.2% of cases achieved coronal alignment within the safe zone (HKA 177-183°). Significant improvements were observed in KSS (part 1: 69.5-95, part 2: 65-94, p < 0.001), while OKS and FJS exhibited optimal outcomes. Two complications were recorded: one aseptic loosening (1.7%) and one early infection (1.7%). Kaplan-Meier survival analysis indicated favourable implant survivorship at a median follow-up of 18 months.</p><p><strong>Conclusion: </strong>FA in image-based robotic TKA is a safe and effective approach for patients with valgus deformity. This procedure resulted in a modest correction of the coronal alignment, where no soft tissue releases were needed. The majority of the cases fell within the target coronal alignment boundaries by only accommodating the individual laxities, suggesting the aim of FA to restore each knee's pre-pathological alignment.</p><p><strong>Level of evidence: </strong>Level IV.</p>","PeriodicalId":17880,"journal":{"name":"Knee Surgery, Sports Traumatology, Arthroscopy","volume":" ","pages":""},"PeriodicalIF":3.3000,"publicationDate":"2025-01-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Functional alignment in robotic-assisted total knee arthroplasty for valgus deformity achieves safe coronal alignment and excellent short-term outcomes.\",\"authors\":\"Pietro Gregori, Christos Koutserimpas, Vasileios Giovanoulis, Cécile Batailler, Elvire Servien, Sébastien Lustig\",\"doi\":\"10.1002/ksa.12585\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>Functional alignment (FA) in total knee arthroplasty (TKA) prioritizes soft tissue balancing and anatomical restoration without systematic correction to neutral alignment. Most studies have focused on varus deformity, with little evidence available about FA in valgus deformity. The hypothesis of the present study was that FA in robotic-assisted TKA for valgus deformity would demonstrate correction of the coronal alignment and yield satisfactory short-term outcomes.</p><p><strong>Methods: </strong>This retrospective study included 58 patients with valgus coronal alignment (hip-knee-angle [HKA] ≥ 183°) who underwent robotic-assisted TKA using the FA technique with a minimum of 1-year follow-up. Outcomes were assessed through the Knee Society Score (KSS), Oxford Knee Score (OKS), Forgotten Joint Score (FJS) and radiographic measurements of alignment and phenotypes. Complication and revision rates were also analyzed.</p><p><strong>Results: </strong>The cohort included 39 females and 19 males with a median age of 70. Post-operatively, 86.2% of cases achieved coronal alignment within the safe zone (HKA 177-183°). Significant improvements were observed in KSS (part 1: 69.5-95, part 2: 65-94, p < 0.001), while OKS and FJS exhibited optimal outcomes. Two complications were recorded: one aseptic loosening (1.7%) and one early infection (1.7%). Kaplan-Meier survival analysis indicated favourable implant survivorship at a median follow-up of 18 months.</p><p><strong>Conclusion: </strong>FA in image-based robotic TKA is a safe and effective approach for patients with valgus deformity. This procedure resulted in a modest correction of the coronal alignment, where no soft tissue releases were needed. The majority of the cases fell within the target coronal alignment boundaries by only accommodating the individual laxities, suggesting the aim of FA to restore each knee's pre-pathological alignment.</p><p><strong>Level of evidence: </strong>Level IV.</p>\",\"PeriodicalId\":17880,\"journal\":{\"name\":\"Knee Surgery, Sports Traumatology, Arthroscopy\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":3.3000,\"publicationDate\":\"2025-01-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Knee Surgery, Sports Traumatology, Arthroscopy\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1002/ksa.12585\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"ORTHOPEDICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Knee Surgery, Sports Traumatology, Arthroscopy","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1002/ksa.12585","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

摘要

目的:全膝关节置换术(TKA)中的功能对齐(FA)优先考虑软组织平衡和解剖恢复,而不需要系统地纠正中性对齐。大多数研究都集中在内翻畸形,很少有证据表明FA在外翻畸形中的作用。本研究的假设是,在外翻畸形的机器人辅助TKA中,FA将证明冠状排列的纠正,并产生令人满意的短期结果。方法:本回顾性研究纳入58例外翻冠状位对准(髋关节-膝关节角度[HKA]≥183°)患者,采用FA技术进行机器人辅助TKA,随访时间至少1年。通过膝关节社会评分(KSS)、牛津膝关节评分(OKS)、遗忘关节评分(FJS)和放射学测量的对齐和表型来评估结果。并对并发症及翻修率进行了分析。结果:该队列包括39名女性和19名男性,中位年龄为70岁。术后86.2%的病例在安全区域(HKA 177-183°)内实现冠状位对齐。KSS有显著改善(第1部分:69.5-95,第2部分:65-94,p)结论:FA在基于图像的机器人TKA中是一种安全有效的治疗外翻畸形的方法。该手术对冠状排列进行了适度的矫正,不需要软组织释放。大多数病例仅通过调节个体松弛度而落在目标冠状位对齐边界内,这表明FA的目的是恢复每个膝关节的病理前对齐。证据等级:四级。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Functional alignment in robotic-assisted total knee arthroplasty for valgus deformity achieves safe coronal alignment and excellent short-term outcomes.

Purpose: Functional alignment (FA) in total knee arthroplasty (TKA) prioritizes soft tissue balancing and anatomical restoration without systematic correction to neutral alignment. Most studies have focused on varus deformity, with little evidence available about FA in valgus deformity. The hypothesis of the present study was that FA in robotic-assisted TKA for valgus deformity would demonstrate correction of the coronal alignment and yield satisfactory short-term outcomes.

Methods: This retrospective study included 58 patients with valgus coronal alignment (hip-knee-angle [HKA] ≥ 183°) who underwent robotic-assisted TKA using the FA technique with a minimum of 1-year follow-up. Outcomes were assessed through the Knee Society Score (KSS), Oxford Knee Score (OKS), Forgotten Joint Score (FJS) and radiographic measurements of alignment and phenotypes. Complication and revision rates were also analyzed.

Results: The cohort included 39 females and 19 males with a median age of 70. Post-operatively, 86.2% of cases achieved coronal alignment within the safe zone (HKA 177-183°). Significant improvements were observed in KSS (part 1: 69.5-95, part 2: 65-94, p < 0.001), while OKS and FJS exhibited optimal outcomes. Two complications were recorded: one aseptic loosening (1.7%) and one early infection (1.7%). Kaplan-Meier survival analysis indicated favourable implant survivorship at a median follow-up of 18 months.

Conclusion: FA in image-based robotic TKA is a safe and effective approach for patients with valgus deformity. This procedure resulted in a modest correction of the coronal alignment, where no soft tissue releases were needed. The majority of the cases fell within the target coronal alignment boundaries by only accommodating the individual laxities, suggesting the aim of FA to restore each knee's pre-pathological alignment.

Level of evidence: Level IV.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
8.10
自引率
18.40%
发文量
418
审稿时长
2 months
期刊介绍: Few other areas of orthopedic surgery and traumatology have undergone such a dramatic evolution in the last 10 years as knee surgery, arthroscopy and sports traumatology. Ranked among the top 33% of journals in both Orthopedics and Sports Sciences, the goal of this European journal is to publish papers about innovative knee surgery, sports trauma surgery and arthroscopy. Each issue features a series of peer-reviewed articles that deal with diagnosis and management and with basic research. Each issue also contains at least one review article about an important clinical problem. Case presentations or short notes about technical innovations are also accepted for publication. The articles cover all aspects of knee surgery and all types of sports trauma; in addition, epidemiology, diagnosis, treatment and prevention, and all types of arthroscopy (not only the knee but also the shoulder, elbow, wrist, hip, ankle, etc.) are addressed. Articles on new diagnostic techniques such as MRI and ultrasound and high-quality articles about the biomechanics of joints, muscles and tendons are included. Although this is largely a clinical journal, it is also open to basic research with clinical relevance. Because the journal is supported by a distinguished European Editorial Board, assisted by an international Advisory Board, you can be assured that the journal maintains the highest standards. Official Clinical Journal of the European Society of Sports Traumatology, Knee Surgery and Arthroscopy (ESSKA).
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信