使用Lugol的碘增强微计算机断层扫描对口腔鳞状细胞癌样本侵袭深度的三维测量:一项原始研究。

IF 2.2 3区 医学 Q2 DENTISTRY, ORAL SURGERY & MEDICINE
Journal of Applied Oral Science Pub Date : 2025-01-13 eCollection Date: 2025-01-01 DOI:10.1590/1678-7757-2024-0304
Jiaxin Yu, Zhouyu Gu, Lichan Wang, Qian Zhang, Yumei Pu, Qingang Hu, Chengwan Xia, Yuxin Wang
{"title":"使用Lugol的碘增强微计算机断层扫描对口腔鳞状细胞癌样本侵袭深度的三维测量:一项原始研究。","authors":"Jiaxin Yu, Zhouyu Gu, Lichan Wang, Qian Zhang, Yumei Pu, Qingang Hu, Chengwan Xia, Yuxin Wang","doi":"10.1590/1678-7757-2024-0304","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>Depth of invasion (DOI) in oral squamous cell carcinoma (OSCC) guides treatment and prognosis but lacks three-dimensional (3D) insight. Thus, this study aimed to investigate the feasibility and accuracy of Lugol's iodine-enhanced micro-computed tomography (CT) for the 3D measurement of DOI in OSCC samples.</p><p><strong>Methodology: </strong>In total, 50 in vitro OSCC samples from Nanjing Stomatological Hospital (July 2022 to January 2024) were subjected to micro-CT imaging with a slice thickness of 50 μm following 3% Lugol iodine staining for 12 h, followed by pathological examination and staining. The panoramic diagnostic scanner digitally measured pathological DOI. The micro-CT DOI was measured by evaluating the voxel value of the boundary of the tumor lesion and comparing it with the pathological examination results. Experienced physicians analyzed both measurements, and statistical analyses were performed to determine their correlation.</p><p><strong>Results: </strong>Lugol iodine-enhanced micro-CT imaging distinguishes various tissue structures, such as tumor tissue, epithelial tissue, muscle tissue, blood vessel structure, and other major tissue structures in 3D space. This imaging technique found and localized micro-tumor lesions (1.82×1.5×1 mm3) when in conjunction with pathological sections. Statistical analysis indicated a strong correlation between pathological DOI and micro-CT DOI (P<.001; r=0.986). During DOI measurement, Lugol iodine-enhanced micro-CT imaging effectively compensated for the loss of 3D space information in the pathological measurements, improving the accuracy of the DOI measurement.</p><p><strong>Conclusions: </strong>Lugol iodine-enhanced micro-CT improves OSCC DOI 3D measurements, enhances pathological staging accuracy, and aids treatment decisions and prognosis.</p>","PeriodicalId":15133,"journal":{"name":"Journal of Applied Oral Science","volume":"33 ","pages":"e20240304"},"PeriodicalIF":2.2000,"publicationDate":"2025-01-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Three-dimensional measurement of the depth of invasion in oral squamous cell carcinoma samples using Lugol's iodine-enhanced micro-computed tomography: an original study.\",\"authors\":\"Jiaxin Yu, Zhouyu Gu, Lichan Wang, Qian Zhang, Yumei Pu, Qingang Hu, Chengwan Xia, Yuxin Wang\",\"doi\":\"10.1590/1678-7757-2024-0304\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objectives: </strong>Depth of invasion (DOI) in oral squamous cell carcinoma (OSCC) guides treatment and prognosis but lacks three-dimensional (3D) insight. Thus, this study aimed to investigate the feasibility and accuracy of Lugol's iodine-enhanced micro-computed tomography (CT) for the 3D measurement of DOI in OSCC samples.</p><p><strong>Methodology: </strong>In total, 50 in vitro OSCC samples from Nanjing Stomatological Hospital (July 2022 to January 2024) were subjected to micro-CT imaging with a slice thickness of 50 μm following 3% Lugol iodine staining for 12 h, followed by pathological examination and staining. The panoramic diagnostic scanner digitally measured pathological DOI. The micro-CT DOI was measured by evaluating the voxel value of the boundary of the tumor lesion and comparing it with the pathological examination results. Experienced physicians analyzed both measurements, and statistical analyses were performed to determine their correlation.</p><p><strong>Results: </strong>Lugol iodine-enhanced micro-CT imaging distinguishes various tissue structures, such as tumor tissue, epithelial tissue, muscle tissue, blood vessel structure, and other major tissue structures in 3D space. This imaging technique found and localized micro-tumor lesions (1.82×1.5×1 mm3) when in conjunction with pathological sections. Statistical analysis indicated a strong correlation between pathological DOI and micro-CT DOI (P<.001; r=0.986). During DOI measurement, Lugol iodine-enhanced micro-CT imaging effectively compensated for the loss of 3D space information in the pathological measurements, improving the accuracy of the DOI measurement.</p><p><strong>Conclusions: </strong>Lugol iodine-enhanced micro-CT improves OSCC DOI 3D measurements, enhances pathological staging accuracy, and aids treatment decisions and prognosis.</p>\",\"PeriodicalId\":15133,\"journal\":{\"name\":\"Journal of Applied Oral Science\",\"volume\":\"33 \",\"pages\":\"e20240304\"},\"PeriodicalIF\":2.2000,\"publicationDate\":\"2025-01-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Applied Oral Science\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1590/1678-7757-2024-0304\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2025/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q2\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Applied Oral Science","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1590/1678-7757-2024-0304","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/1/1 0:00:00","PubModel":"eCollection","JCR":"Q2","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

目的:口腔鳞状细胞癌(OSCC)的浸润深度(DOI)指导治疗和预后,但缺乏三维(3D)洞察力。因此,本研究旨在探讨Lugol's碘增强微计算机断层扫描(CT)用于OSCC样品DOI三维测量的可行性和准确性。方法:选取南京口腔医院(2022年7月~ 2024年1月)50例离体OSCC标本,经3% Lugol碘染色12 h,切片厚度为50 μm的显微ct成像,然后进行病理检查和染色。全景诊断扫描仪数字化测量病理DOI。通过评估肿瘤病灶边界体素值,并与病理检查结果比较,测量micro-CT DOI。经验丰富的医生分析了这两种测量结果,并进行了统计分析以确定它们的相关性。结果:Lugol碘增强微ct成像在三维空间中区分了多种组织结构,如肿瘤组织、上皮组织、肌肉组织、血管结构等主要组织结构。当结合病理切片时,该成像技术发现并定位微肿瘤病变(1.82×1.5×1 mm3)。结论:Lugol碘增强微ct可改善OSCC DOI 3D测量,提高病理分期准确性,有助于治疗决策和预后。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Three-dimensional measurement of the depth of invasion in oral squamous cell carcinoma samples using Lugol's iodine-enhanced micro-computed tomography: an original study.

Objectives: Depth of invasion (DOI) in oral squamous cell carcinoma (OSCC) guides treatment and prognosis but lacks three-dimensional (3D) insight. Thus, this study aimed to investigate the feasibility and accuracy of Lugol's iodine-enhanced micro-computed tomography (CT) for the 3D measurement of DOI in OSCC samples.

Methodology: In total, 50 in vitro OSCC samples from Nanjing Stomatological Hospital (July 2022 to January 2024) were subjected to micro-CT imaging with a slice thickness of 50 μm following 3% Lugol iodine staining for 12 h, followed by pathological examination and staining. The panoramic diagnostic scanner digitally measured pathological DOI. The micro-CT DOI was measured by evaluating the voxel value of the boundary of the tumor lesion and comparing it with the pathological examination results. Experienced physicians analyzed both measurements, and statistical analyses were performed to determine their correlation.

Results: Lugol iodine-enhanced micro-CT imaging distinguishes various tissue structures, such as tumor tissue, epithelial tissue, muscle tissue, blood vessel structure, and other major tissue structures in 3D space. This imaging technique found and localized micro-tumor lesions (1.82×1.5×1 mm3) when in conjunction with pathological sections. Statistical analysis indicated a strong correlation between pathological DOI and micro-CT DOI (P<.001; r=0.986). During DOI measurement, Lugol iodine-enhanced micro-CT imaging effectively compensated for the loss of 3D space information in the pathological measurements, improving the accuracy of the DOI measurement.

Conclusions: Lugol iodine-enhanced micro-CT improves OSCC DOI 3D measurements, enhances pathological staging accuracy, and aids treatment decisions and prognosis.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Applied Oral Science
Journal of Applied Oral Science 医学-牙科与口腔外科
CiteScore
4.80
自引率
3.70%
发文量
46
审稿时长
4-8 weeks
期刊介绍: The Journal of Applied Oral Science is committed in publishing the scientific and technologic advances achieved by the dental community, according to the quality indicators and peer reviewed material, with the objective of assuring its acceptability at the local, regional, national and international levels. The primary goal of The Journal of Applied Oral Science is to publish the outcomes of original investigations as well as invited case reports and invited reviews in the field of Dentistry and related areas.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信