{"title":"一项回顾性队列研究:超短种植体(≤6mm)用于萎缩后颌的临床和影像学结果。","authors":"Stefano Sivolella, Stefano Giovannini, Joana Berberi, Michele Stocchero, Giulia Brunello","doi":"10.1186/s40729-025-00592-z","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>This study aimed at investigating implant survival rate and marginal bone loss (MBL) around extra-short implants. The impact of the loading protocol and of the use of an intermediate abutment was also evaluated, to explore possible differences in terms of the outcome measures.</p><p><strong>Materials and methods: </strong>Patients with single or multiple mandibular or maxillary posterior edentulism rehabilitated using extra-short 5-6 mm long implants were included. Different prosthetic protocols were used. Clinical and radiological follow-up was 5 years. The outcomes measures were implant survival and MBL.</p><p><strong>Results: </strong>The analysis included 56 implants placed in 34 adults (12 males and 22 females; mean age 60 years, SD 11). Six implants failed during a median follow-up of 5 years and 4 of them were recorded in one patient at 2-year follow-up. The 5-year implant survival was 89% overall (87% in conventional and 94% in immediate loading). At univariate analysis, during follow-up immediate loading was associated with higher MBL (mean variation 0.21 mm, 95%CI 0.01 to 0.40; p = 0.02), while intermediate abutment was associated with lower MBL (mean variation -0.23 mm, 95%CI -0.39 to -0.09; p = 0.003). Multivariable analysis confirmed that immediate loading was associated with higher MBL.</p><p><strong>Conclusion: </strong>Within its limitations, this study showed that extra-short implants under immediate loading conditions can be a reliable solution. The application of horizontal and vertical platform switching with the use of intermediate abutments seems to be able to contribute to the reduction of MBL.</p>","PeriodicalId":14076,"journal":{"name":"International Journal of Implant Dentistry","volume":"11 1","pages":"4"},"PeriodicalIF":3.1000,"publicationDate":"2025-01-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11747052/pdf/","citationCount":"0","resultStr":"{\"title\":\"Clinical and radiographic outcomes of extra-short implants (≤ 6 mm) in the posterior atrophic jaws: a retrospective cohort study.\",\"authors\":\"Stefano Sivolella, Stefano Giovannini, Joana Berberi, Michele Stocchero, Giulia Brunello\",\"doi\":\"10.1186/s40729-025-00592-z\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objective: </strong>This study aimed at investigating implant survival rate and marginal bone loss (MBL) around extra-short implants. The impact of the loading protocol and of the use of an intermediate abutment was also evaluated, to explore possible differences in terms of the outcome measures.</p><p><strong>Materials and methods: </strong>Patients with single or multiple mandibular or maxillary posterior edentulism rehabilitated using extra-short 5-6 mm long implants were included. Different prosthetic protocols were used. Clinical and radiological follow-up was 5 years. The outcomes measures were implant survival and MBL.</p><p><strong>Results: </strong>The analysis included 56 implants placed in 34 adults (12 males and 22 females; mean age 60 years, SD 11). Six implants failed during a median follow-up of 5 years and 4 of them were recorded in one patient at 2-year follow-up. The 5-year implant survival was 89% overall (87% in conventional and 94% in immediate loading). At univariate analysis, during follow-up immediate loading was associated with higher MBL (mean variation 0.21 mm, 95%CI 0.01 to 0.40; p = 0.02), while intermediate abutment was associated with lower MBL (mean variation -0.23 mm, 95%CI -0.39 to -0.09; p = 0.003). Multivariable analysis confirmed that immediate loading was associated with higher MBL.</p><p><strong>Conclusion: </strong>Within its limitations, this study showed that extra-short implants under immediate loading conditions can be a reliable solution. The application of horizontal and vertical platform switching with the use of intermediate abutments seems to be able to contribute to the reduction of MBL.</p>\",\"PeriodicalId\":14076,\"journal\":{\"name\":\"International Journal of Implant Dentistry\",\"volume\":\"11 1\",\"pages\":\"4\"},\"PeriodicalIF\":3.1000,\"publicationDate\":\"2025-01-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11747052/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Implant Dentistry\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1186/s40729-025-00592-z\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Implant Dentistry","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s40729-025-00592-z","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0
摘要
目的:研究超短种植体种植体的成活率和边缘骨损失(MBL)。还评估了加载方案和使用中间基台的影响,以探讨结果测量方面可能存在的差异。材料和方法:采用超短5-6 mm长种植体修复单侧或多侧下颌或上颌后牙患者。使用了不同的假肢方案。临床及放射学随访5年。结果测量种植体存活和MBL。结果:分析包括34名成人(12名男性,22名女性;平均年龄60岁,SD 11)。在中位随访5年期间,有6例植入物失败,其中1例患者在随访2年时记录了4例植入物失败。5年种植体总体存活率为89%(常规种植体87%,即刻种植体94%)。在单因素分析中,在随访期间,立即加载与较高的MBL相关(平均变化0.21 mm, 95%CI 0.01至0.40;p = 0.02),而中间基台与MBL较低相关(平均变异-0.23 mm, 95%CI -0.39 ~ -0.09;p = 0.003)。多变量分析证实,立即加载与较高的MBL相关。结论:在其局限性内,本研究表明,在即时加载条件下,超短种植体是可靠的解决方案。水平和垂直平台切换的应用与使用中间基台似乎能够有助于减少MBL。
Clinical and radiographic outcomes of extra-short implants (≤ 6 mm) in the posterior atrophic jaws: a retrospective cohort study.
Objective: This study aimed at investigating implant survival rate and marginal bone loss (MBL) around extra-short implants. The impact of the loading protocol and of the use of an intermediate abutment was also evaluated, to explore possible differences in terms of the outcome measures.
Materials and methods: Patients with single or multiple mandibular or maxillary posterior edentulism rehabilitated using extra-short 5-6 mm long implants were included. Different prosthetic protocols were used. Clinical and radiological follow-up was 5 years. The outcomes measures were implant survival and MBL.
Results: The analysis included 56 implants placed in 34 adults (12 males and 22 females; mean age 60 years, SD 11). Six implants failed during a median follow-up of 5 years and 4 of them were recorded in one patient at 2-year follow-up. The 5-year implant survival was 89% overall (87% in conventional and 94% in immediate loading). At univariate analysis, during follow-up immediate loading was associated with higher MBL (mean variation 0.21 mm, 95%CI 0.01 to 0.40; p = 0.02), while intermediate abutment was associated with lower MBL (mean variation -0.23 mm, 95%CI -0.39 to -0.09; p = 0.003). Multivariable analysis confirmed that immediate loading was associated with higher MBL.
Conclusion: Within its limitations, this study showed that extra-short implants under immediate loading conditions can be a reliable solution. The application of horizontal and vertical platform switching with the use of intermediate abutments seems to be able to contribute to the reduction of MBL.
期刊介绍:
The International Journal of Implant Dentistry is a peer-reviewed open access journal published under the SpringerOpen brand. The journal is dedicated to promoting the exchange and discussion of all research areas relevant to implant dentistry in the form of systematic literature or invited reviews, prospective and retrospective clinical studies, clinical case reports, basic laboratory and animal research, and articles on material research and engineering.