囊性纤维化患者雾化器的微生物污染。

IF 1.3 Q3 PEDIATRICS
Cansu Yilmaz Yegit, Pinar Ergenekon, Nurcan Duman, Hakan Mursaloglu, Muruvvet Cenk, Burcu Suzer Uzunoglu, Gamze Tastan, Yasemin Gokdemir, Ela Erdem Eralp, Aysegul Karahasan Yagci, Fazilet Karakoc, Bulent Karadag
{"title":"囊性纤维化患者雾化器的微生物污染。","authors":"Cansu Yilmaz Yegit, Pinar Ergenekon, Nurcan Duman, Hakan Mursaloglu, Muruvvet Cenk, Burcu Suzer Uzunoglu, Gamze Tastan, Yasemin Gokdemir, Ela Erdem Eralp, Aysegul Karahasan Yagci, Fazilet Karakoc, Bulent Karadag","doi":"10.5152/TurkArchPediatr.2025.24003","DOIUrl":null,"url":null,"abstract":"<p><p>Objective: Nebulizer contamination has potential harmful effects on the respiratory system. The aim was to investigate the contamination profile of the nebulizers in cystic fibrosis patients and evaluate the relationship between hygiene practices and microbial contamination. Materials and Methods: Microbiological swab samples were taken from 3 different locations of the nebulizers of 102 patients. A questionnaire regarding nebulizer hygiene practices was applied to participants. Results: Contamination rate was 40.2%, while chambers were the most contaminated area. The bacterial contamination rate was 37.3%, with gram-negative bacterial growth being predominant. The organisms identified were mostly environmental or floral. Only 3 of the patients were performing the whole steps correctly. This number was not sufficient to assess the relationship between nebulizer cleaning and disinfection practices and microbial growth from nebulizers. When the relationship between nebulizer cleaning/disinfection frequencies, methods, and storage locations was evaluated separately with microbial growth from nebulizers, no statistically significant relationship was found for all (P > .05 for all). Conclusion: The nebulizer contamination rate with pathogenic microorganisms is low in the present study. Regular educational interventions regarding nebulizer hygiene practices should be implemented in all Cystic Fibrosis Centers.</p>","PeriodicalId":75267,"journal":{"name":"Turkish archives of pediatrics","volume":"60 1","pages":"22-28"},"PeriodicalIF":1.3000,"publicationDate":"2025-01-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11736810/pdf/","citationCount":"0","resultStr":"{\"title\":\"Microbial Contamination of Nebulizers in Patients With Cystic Fibrosis.\",\"authors\":\"Cansu Yilmaz Yegit, Pinar Ergenekon, Nurcan Duman, Hakan Mursaloglu, Muruvvet Cenk, Burcu Suzer Uzunoglu, Gamze Tastan, Yasemin Gokdemir, Ela Erdem Eralp, Aysegul Karahasan Yagci, Fazilet Karakoc, Bulent Karadag\",\"doi\":\"10.5152/TurkArchPediatr.2025.24003\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Objective: Nebulizer contamination has potential harmful effects on the respiratory system. The aim was to investigate the contamination profile of the nebulizers in cystic fibrosis patients and evaluate the relationship between hygiene practices and microbial contamination. Materials and Methods: Microbiological swab samples were taken from 3 different locations of the nebulizers of 102 patients. A questionnaire regarding nebulizer hygiene practices was applied to participants. Results: Contamination rate was 40.2%, while chambers were the most contaminated area. The bacterial contamination rate was 37.3%, with gram-negative bacterial growth being predominant. The organisms identified were mostly environmental or floral. Only 3 of the patients were performing the whole steps correctly. This number was not sufficient to assess the relationship between nebulizer cleaning and disinfection practices and microbial growth from nebulizers. When the relationship between nebulizer cleaning/disinfection frequencies, methods, and storage locations was evaluated separately with microbial growth from nebulizers, no statistically significant relationship was found for all (P > .05 for all). Conclusion: The nebulizer contamination rate with pathogenic microorganisms is low in the present study. Regular educational interventions regarding nebulizer hygiene practices should be implemented in all Cystic Fibrosis Centers.</p>\",\"PeriodicalId\":75267,\"journal\":{\"name\":\"Turkish archives of pediatrics\",\"volume\":\"60 1\",\"pages\":\"22-28\"},\"PeriodicalIF\":1.3000,\"publicationDate\":\"2025-01-02\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11736810/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Turkish archives of pediatrics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5152/TurkArchPediatr.2025.24003\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"PEDIATRICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Turkish archives of pediatrics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5152/TurkArchPediatr.2025.24003","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"PEDIATRICS","Score":null,"Total":0}
引用次数: 0

摘要

目的:雾化器污染对呼吸系统有潜在的危害。目的是调查囊性纤维化患者雾化器的污染情况,并评估卫生习惯与微生物污染之间的关系。材料与方法:从102例患者雾化器的3个不同部位采集微生物拭子样本。对参与者进行了一份关于雾化器卫生习惯的问卷调查。结果:污染率为40.2%,其中箱体是污染最严重的区域。细菌污染率为37.3%,以革兰氏阴性菌为主。鉴定的生物主要是环境或植物。只有3名患者正确地完成了整个步骤。这个数字不足以评估雾化器清洁和消毒实践与雾化器微生物生长之间的关系。当分别评估雾化器清洁/消毒频率、方法和储存位置与雾化器微生物生长之间的关系时,没有发现所有关系具有统计学意义(P < 0.05)。结论:本研究的雾化器病原菌污染率较低。应在所有囊性纤维化中心实施有关雾化器卫生习惯的定期教育干预。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Microbial Contamination of Nebulizers in Patients With Cystic Fibrosis.

Objective: Nebulizer contamination has potential harmful effects on the respiratory system. The aim was to investigate the contamination profile of the nebulizers in cystic fibrosis patients and evaluate the relationship between hygiene practices and microbial contamination. Materials and Methods: Microbiological swab samples were taken from 3 different locations of the nebulizers of 102 patients. A questionnaire regarding nebulizer hygiene practices was applied to participants. Results: Contamination rate was 40.2%, while chambers were the most contaminated area. The bacterial contamination rate was 37.3%, with gram-negative bacterial growth being predominant. The organisms identified were mostly environmental or floral. Only 3 of the patients were performing the whole steps correctly. This number was not sufficient to assess the relationship between nebulizer cleaning and disinfection practices and microbial growth from nebulizers. When the relationship between nebulizer cleaning/disinfection frequencies, methods, and storage locations was evaluated separately with microbial growth from nebulizers, no statistically significant relationship was found for all (P > .05 for all). Conclusion: The nebulizer contamination rate with pathogenic microorganisms is low in the present study. Regular educational interventions regarding nebulizer hygiene practices should be implemented in all Cystic Fibrosis Centers.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
2.00
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信