Andreea Slavescu MBBS , Fernando Picazo Pineda MD, FEBVS (Hons), FRACS (Vascular) , Joseph Hockley MD, FRACS (Vascular)
{"title":"通过颈总动脉切开术去除困在新生儿大脑中动脉中的微导管。","authors":"Andreea Slavescu MBBS , Fernando Picazo Pineda MD, FEBVS (Hons), FRACS (Vascular) , Joseph Hockley MD, FRACS (Vascular)","doi":"10.1016/j.jvscit.2024.101683","DOIUrl":null,"url":null,"abstract":"<div><div>A 2-day-old neonate was referred to the vascular surgery service owing to concerns of limb perfusion after entrapment of a microcatheter in the middle cerebral artery. The catheter was inserted via the umbilical artery to treat a vein of Galen arteriovenous malformation. This catheter inadvertently became entrapped owing to device failure, was cut at the insertion site, and left in situ for 3 months. At this stage, the decision was made to remove the distal portion of the catheter via right common carotid arteriotomy. This intervention was straightforward, effective and safe, and the patient had no complications at 6 months.</div></div>","PeriodicalId":45071,"journal":{"name":"Journal of Vascular Surgery Cases Innovations and Techniques","volume":"11 1","pages":"Article 101683"},"PeriodicalIF":0.7000,"publicationDate":"2025-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11714415/pdf/","citationCount":"0","resultStr":"{\"title\":\"Removal of microcatheter entrapped in the middle cerebral artery in a neonate via common carotid arteriotomy\",\"authors\":\"Andreea Slavescu MBBS , Fernando Picazo Pineda MD, FEBVS (Hons), FRACS (Vascular) , Joseph Hockley MD, FRACS (Vascular)\",\"doi\":\"10.1016/j.jvscit.2024.101683\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><div>A 2-day-old neonate was referred to the vascular surgery service owing to concerns of limb perfusion after entrapment of a microcatheter in the middle cerebral artery. The catheter was inserted via the umbilical artery to treat a vein of Galen arteriovenous malformation. This catheter inadvertently became entrapped owing to device failure, was cut at the insertion site, and left in situ for 3 months. At this stage, the decision was made to remove the distal portion of the catheter via right common carotid arteriotomy. This intervention was straightforward, effective and safe, and the patient had no complications at 6 months.</div></div>\",\"PeriodicalId\":45071,\"journal\":{\"name\":\"Journal of Vascular Surgery Cases Innovations and Techniques\",\"volume\":\"11 1\",\"pages\":\"Article 101683\"},\"PeriodicalIF\":0.7000,\"publicationDate\":\"2025-02-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11714415/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Vascular Surgery Cases Innovations and Techniques\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2468428724002673\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"SURGERY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Vascular Surgery Cases Innovations and Techniques","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2468428724002673","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"SURGERY","Score":null,"Total":0}
Removal of microcatheter entrapped in the middle cerebral artery in a neonate via common carotid arteriotomy
A 2-day-old neonate was referred to the vascular surgery service owing to concerns of limb perfusion after entrapment of a microcatheter in the middle cerebral artery. The catheter was inserted via the umbilical artery to treat a vein of Galen arteriovenous malformation. This catheter inadvertently became entrapped owing to device failure, was cut at the insertion site, and left in situ for 3 months. At this stage, the decision was made to remove the distal portion of the catheter via right common carotid arteriotomy. This intervention was straightforward, effective and safe, and the patient had no complications at 6 months.
期刊介绍:
Journal of Vascular Surgery Cases and Innovative Techniques is a surgical journal dedicated to publishing peer review high quality case reports, vascular images and innovative techniques related to all aspects of arterial, venous, and lymphatic diseases and disorders, including vascular trauma, malformations, wound care and the placement and maintenance of arterio-venous dialysis accesses with an emphasis on the practicing clinician. The Journal seeks to provide novel and timely information to vascular surgeons, interventionalists, phlebologists, wound care specialists, and allied health professionals involved with the management of patients with the entire spectrum of vascular disorders.