{"title":"先天性心脏病儿童心脏计算机断层扫描峰值增强时间与患者特征的相关性","authors":"T Visakh, P S Priya, Nitika C Panakkal, Gunjan Banga, Koteshwar Prakashini","doi":"10.25259/JCIS_153_2024","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>Cardiac computed tomography (CCT) plays a key role in diagnosing congenital heart disease (CHD), emphasizing the need for specialized protocols in newborns due to CHD's complexity. The aim is to explore the relationship between peak enhancement time (PET) and various parameters during CHD assessment with CCT.</p><p><strong>Material and methods: </strong>The study involved 38 CHD patients undergoing CCT, with observations made on their heart rate, respiratory rate, saturation, cardiac output, weight, height, and age. The PET for each case was determined, and Spearman's rank correlation was employed to evaluate the association between these parameters and the PET.</p><p><strong>Results: </strong>The median PET was 20.63 s, with a mean aortic Hounsfield unit of 512.16 ± 160.56. A moderate negative correlation was found between PET and both heart rates (r = -0.42, <i>P</i> = 0.009) and respiratory rates (r = -0.41, <i>P</i> = 0.01), whereas a negligible positive correlation (r = 0.19, <i>P</i> = 0.25) was observed with SpO2. A moderate positive correlation was noted between PET and both weight (r = 0.44, <i>P</i> = 0.005) and height (r = 0.40, <i>P</i> = 0.01). In addition, there were significant differences in median PET across different age categories.</p><p><strong>Conclusion: </strong>The findings conclude that PET during CCT is significantly associated with heart rate and respiratory rate. An increase in these rates corresponds to a notable decrease in PET. Consequently, the study recommends minimizing scan delays in CCT for patients exhibiting higher heart rates.</p>","PeriodicalId":15512,"journal":{"name":"Journal of Clinical Imaging Science","volume":"14 ","pages":"50"},"PeriodicalIF":1.1000,"publicationDate":"2024-12-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11704290/pdf/","citationCount":"0","resultStr":"{\"title\":\"Correlation of patient characteristics with peak enhancement time for pediatric cardiac computed tomography in congenital heart disease.\",\"authors\":\"T Visakh, P S Priya, Nitika C Panakkal, Gunjan Banga, Koteshwar Prakashini\",\"doi\":\"10.25259/JCIS_153_2024\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objectives: </strong>Cardiac computed tomography (CCT) plays a key role in diagnosing congenital heart disease (CHD), emphasizing the need for specialized protocols in newborns due to CHD's complexity. The aim is to explore the relationship between peak enhancement time (PET) and various parameters during CHD assessment with CCT.</p><p><strong>Material and methods: </strong>The study involved 38 CHD patients undergoing CCT, with observations made on their heart rate, respiratory rate, saturation, cardiac output, weight, height, and age. The PET for each case was determined, and Spearman's rank correlation was employed to evaluate the association between these parameters and the PET.</p><p><strong>Results: </strong>The median PET was 20.63 s, with a mean aortic Hounsfield unit of 512.16 ± 160.56. A moderate negative correlation was found between PET and both heart rates (r = -0.42, <i>P</i> = 0.009) and respiratory rates (r = -0.41, <i>P</i> = 0.01), whereas a negligible positive correlation (r = 0.19, <i>P</i> = 0.25) was observed with SpO2. A moderate positive correlation was noted between PET and both weight (r = 0.44, <i>P</i> = 0.005) and height (r = 0.40, <i>P</i> = 0.01). In addition, there were significant differences in median PET across different age categories.</p><p><strong>Conclusion: </strong>The findings conclude that PET during CCT is significantly associated with heart rate and respiratory rate. An increase in these rates corresponds to a notable decrease in PET. Consequently, the study recommends minimizing scan delays in CCT for patients exhibiting higher heart rates.</p>\",\"PeriodicalId\":15512,\"journal\":{\"name\":\"Journal of Clinical Imaging Science\",\"volume\":\"14 \",\"pages\":\"50\"},\"PeriodicalIF\":1.1000,\"publicationDate\":\"2024-12-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11704290/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Clinical Imaging Science\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.25259/JCIS_153_2024\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q3\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Clinical Imaging Science","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.25259/JCIS_153_2024","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

摘要

目的:心脏计算机断层扫描(CCT)在先天性心脏病(CHD)的诊断中起着关键作用,强调由于CHD的复杂性,需要专门的新生儿方案。目的是探讨CCT评估冠心病时峰值增强时间(PET)与各参数之间的关系。材料和方法:本研究纳入38例接受CCT的冠心病患者,观察他们的心率、呼吸频率、饱和度、心输出量、体重、身高和年龄。确定每个病例的PET,并采用Spearman等级相关来评估这些参数与PET之间的相关性。结果:PET中位数为20.63 s,主动脉霍斯菲尔德单位平均值为512.16±160.56。PET与心率(r = -0.42, P = 0.009)和呼吸频率(r = -0.41, P = 0.01)呈中度负相关,而与SpO2呈正相关(r = 0.19, P = 0.25)。PET与体重(r = 0.44, P = 0.005)、身高(r = 0.40, P = 0.01)均呈中度正相关。此外,不同年龄段的PET中位数存在显著差异。结论:CCT期间PET与心率、呼吸频率有显著相关性。这些比率的增加对应于PET的显著减少。因此,该研究建议对心率较高的患者尽量减少CCT扫描延迟。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Correlation of patient characteristics with peak enhancement time for pediatric cardiac computed tomography in congenital heart disease.

Objectives: Cardiac computed tomography (CCT) plays a key role in diagnosing congenital heart disease (CHD), emphasizing the need for specialized protocols in newborns due to CHD's complexity. The aim is to explore the relationship between peak enhancement time (PET) and various parameters during CHD assessment with CCT.

Material and methods: The study involved 38 CHD patients undergoing CCT, with observations made on their heart rate, respiratory rate, saturation, cardiac output, weight, height, and age. The PET for each case was determined, and Spearman's rank correlation was employed to evaluate the association between these parameters and the PET.

Results: The median PET was 20.63 s, with a mean aortic Hounsfield unit of 512.16 ± 160.56. A moderate negative correlation was found between PET and both heart rates (r = -0.42, P = 0.009) and respiratory rates (r = -0.41, P = 0.01), whereas a negligible positive correlation (r = 0.19, P = 0.25) was observed with SpO2. A moderate positive correlation was noted between PET and both weight (r = 0.44, P = 0.005) and height (r = 0.40, P = 0.01). In addition, there were significant differences in median PET across different age categories.

Conclusion: The findings conclude that PET during CCT is significantly associated with heart rate and respiratory rate. An increase in these rates corresponds to a notable decrease in PET. Consequently, the study recommends minimizing scan delays in CCT for patients exhibiting higher heart rates.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Clinical Imaging Science
Journal of Clinical Imaging Science RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
2.00
自引率
0.00%
发文量
65
期刊介绍: The Journal of Clinical Imaging Science (JCIS) is an open access peer-reviewed journal committed to publishing high-quality articles in the field of Imaging Science. The journal aims to present Imaging Science and relevant clinical information in an understandable and useful format. The journal is owned and published by the Scientific Scholar. Audience Our audience includes Radiologists, Researchers, Clinicians, medical professionals and students. Review process JCIS has a highly rigorous peer-review process that makes sure that manuscripts are scientifically accurate, relevant, novel and important. Authors disclose all conflicts, affiliations and financial associations such that the published content is not biased.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信