低温球囊消融治疗心房颤动患者中炎症在房颤复发中的重要性。

Q3 Medicine
Deniz Elcik , Aydin Tuncay , Mustafa Fehmi Bireciklioglu , Mehmet Tugrul İnanc
{"title":"低温球囊消融治疗心房颤动患者中炎症在房颤复发中的重要性。","authors":"Deniz Elcik ,&nbsp;Aydin Tuncay ,&nbsp;Mustafa Fehmi Bireciklioglu ,&nbsp;Mehmet Tugrul İnanc","doi":"10.1016/j.ipej.2024.12.005","DOIUrl":null,"url":null,"abstract":"<div><h3>Aim/background</h3><div>Although atrial fibrillation is the most common rhythm problem, the results of treatment to restore sinus rhythm are still not satisfactory. Nearly half of patients undergoing ablation relapse within one year. Therefore, triggered activities may not be the only cause. Inflammation is quite common in AF. In this study, we investigated the effect of PIV, an inflammatory marker, on recurrence.</div></div><div><h3>Methods</h3><div>A total of 157 patients who underwent ablation with cryo balloon were included in the study. One-year follow-up was evaluated for causes of recurrence.</div></div><div><h3>Results</h3><div>When the inflammatory parameters between the two groups are analyzed, CRP (5.9 [5.0–6.9] vs 9.7 [7.6–11.9], p &lt; 0.001), NL ratio (2.8 [2.5–3.0] vs 6.4 [5.0–6.8], p &lt; 0.001), SII2 (618.5 [557.1–679.9] vs 1798.9 [1305.8–2292.1], p &lt; 0.001), PIV (355.9 [313.4–398.4] vs 1832 [1317.8–2347.1], p &lt; 001) were significantly higher in the AF recurrence group. ROC analysis showed that PIV had the best sensitivity and specificity.</div></div><div><h3>Conclusions</h3><div>Inflammation has been found to be a cause of AF recurrence and PIV is one of the best markers for this.</div></div>","PeriodicalId":35900,"journal":{"name":"Indian Pacing and Electrophysiology Journal","volume":"25 1","pages":"Pages 14-19"},"PeriodicalIF":0.0000,"publicationDate":"2025-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The importance of inflammation in atrial fibrillation recurrence in patients with atrial fibrillation treated with Cryo balloon ablation\",\"authors\":\"Deniz Elcik ,&nbsp;Aydin Tuncay ,&nbsp;Mustafa Fehmi Bireciklioglu ,&nbsp;Mehmet Tugrul İnanc\",\"doi\":\"10.1016/j.ipej.2024.12.005\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Aim/background</h3><div>Although atrial fibrillation is the most common rhythm problem, the results of treatment to restore sinus rhythm are still not satisfactory. Nearly half of patients undergoing ablation relapse within one year. Therefore, triggered activities may not be the only cause. Inflammation is quite common in AF. In this study, we investigated the effect of PIV, an inflammatory marker, on recurrence.</div></div><div><h3>Methods</h3><div>A total of 157 patients who underwent ablation with cryo balloon were included in the study. One-year follow-up was evaluated for causes of recurrence.</div></div><div><h3>Results</h3><div>When the inflammatory parameters between the two groups are analyzed, CRP (5.9 [5.0–6.9] vs 9.7 [7.6–11.9], p &lt; 0.001), NL ratio (2.8 [2.5–3.0] vs 6.4 [5.0–6.8], p &lt; 0.001), SII2 (618.5 [557.1–679.9] vs 1798.9 [1305.8–2292.1], p &lt; 0.001), PIV (355.9 [313.4–398.4] vs 1832 [1317.8–2347.1], p &lt; 001) were significantly higher in the AF recurrence group. ROC analysis showed that PIV had the best sensitivity and specificity.</div></div><div><h3>Conclusions</h3><div>Inflammation has been found to be a cause of AF recurrence and PIV is one of the best markers for this.</div></div>\",\"PeriodicalId\":35900,\"journal\":{\"name\":\"Indian Pacing and Electrophysiology Journal\",\"volume\":\"25 1\",\"pages\":\"Pages 14-19\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2025-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Indian Pacing and Electrophysiology Journal\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0972629224001670\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Indian Pacing and Electrophysiology Journal","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0972629224001670","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

摘要

目的/背景虽然心房颤动是最常见的心律问题,但恢复窦性心律的治疗结果仍不令人满意。近一半接受消融术的患者在一年内复发。因此,触发的活动可能不是唯一的原因。炎症在房颤中很常见。在本研究中,我们研究了PIV(一种炎症标志物)对房颤复发的影响。方法选取157例行冷冻球囊消融术的患者作为研究对象。随访1年,评估复发原因。结果两组患者炎症参数比较,CRP (5.9 [5.0-6.9] vs . 9.7 [7.6-11.9], p <;0.001),问比(2.8(2.5 - -3.0)和6.4 (5.0 - -6.8),p & lt;0.001), SII2(618.5(557.1 - -679.9)和1798.9 (1305.8 - -2292.1),p & lt;0.001), PIV(355.9[313.4—-398.4]vs 1832 [1317.8 - -2347.1], p & lt;(001)在AF复发组中明显增高。ROC分析显示PIV具有最佳的敏感性和特异性。结论炎症是房颤复发的原因之一,PIV是房颤复发的最佳标志物之一。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
The importance of inflammation in atrial fibrillation recurrence in patients with atrial fibrillation treated with Cryo balloon ablation

Aim/background

Although atrial fibrillation is the most common rhythm problem, the results of treatment to restore sinus rhythm are still not satisfactory. Nearly half of patients undergoing ablation relapse within one year. Therefore, triggered activities may not be the only cause. Inflammation is quite common in AF. In this study, we investigated the effect of PIV, an inflammatory marker, on recurrence.

Methods

A total of 157 patients who underwent ablation with cryo balloon were included in the study. One-year follow-up was evaluated for causes of recurrence.

Results

When the inflammatory parameters between the two groups are analyzed, CRP (5.9 [5.0–6.9] vs 9.7 [7.6–11.9], p < 0.001), NL ratio (2.8 [2.5–3.0] vs 6.4 [5.0–6.8], p < 0.001), SII2 (618.5 [557.1–679.9] vs 1798.9 [1305.8–2292.1], p < 0.001), PIV (355.9 [313.4–398.4] vs 1832 [1317.8–2347.1], p < 001) were significantly higher in the AF recurrence group. ROC analysis showed that PIV had the best sensitivity and specificity.

Conclusions

Inflammation has been found to be a cause of AF recurrence and PIV is one of the best markers for this.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Indian Pacing and Electrophysiology Journal
Indian Pacing and Electrophysiology Journal Medicine-Cardiology and Cardiovascular Medicine
CiteScore
2.20
自引率
0.00%
发文量
91
审稿时长
61 days
期刊介绍: Indian Pacing and Electrophysiology Journal is a peer reviewed online journal devoted to cardiac pacing and electrophysiology. Editorial Advisory Board includes eminent personalities in the field of cardiac pacing and electrophysiology from Asia, Australia, Europe and North America.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信