利用扫描电子显微镜提高铀微粒质谱分析的准确性

IF 1 4区 化学 Q4 CHEMISTRY, ANALYTICAL
Yu. A. Komarov, V. A. Stebelkov
{"title":"利用扫描电子显微镜提高铀微粒质谱分析的准确性","authors":"Yu. A. Komarov,&nbsp;V. A. Stebelkov","doi":"10.1134/S1061934824701223","DOIUrl":null,"url":null,"abstract":"<p>A sample containing microparticles of two different uranium materials with distinct uranium isotopic compositions was analyzed during an international experiment. Mass spectrometric analysis of 25 particles revealed that, within the measurement error, six particles had an isotopic composition consistent with that of the first material, and three particles were consistent with the second material. However, the uranium isotopic composition of the remaining 16 particles did not match either of the known materials. This indicates that the preliminary examination of uranium microparticles by scanning electron microscopy can identify particles carrying information about the isotopic composition of the source materials.</p>","PeriodicalId":606,"journal":{"name":"Journal of Analytical Chemistry","volume":"79 13","pages":"1918 - 1922"},"PeriodicalIF":1.0000,"publicationDate":"2024-12-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Use of Scanning Electron Microscopy to Enhance the Accuracy of Mass Spectrometry Analysis of Uranium Microparticles\",\"authors\":\"Yu. A. Komarov,&nbsp;V. A. Stebelkov\",\"doi\":\"10.1134/S1061934824701223\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>A sample containing microparticles of two different uranium materials with distinct uranium isotopic compositions was analyzed during an international experiment. Mass spectrometric analysis of 25 particles revealed that, within the measurement error, six particles had an isotopic composition consistent with that of the first material, and three particles were consistent with the second material. However, the uranium isotopic composition of the remaining 16 particles did not match either of the known materials. This indicates that the preliminary examination of uranium microparticles by scanning electron microscopy can identify particles carrying information about the isotopic composition of the source materials.</p>\",\"PeriodicalId\":606,\"journal\":{\"name\":\"Journal of Analytical Chemistry\",\"volume\":\"79 13\",\"pages\":\"1918 - 1922\"},\"PeriodicalIF\":1.0000,\"publicationDate\":\"2024-12-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Analytical Chemistry\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://link.springer.com/article/10.1134/S1061934824701223\",\"RegionNum\":4,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Analytical Chemistry","FirstCategoryId":"92","ListUrlMain":"https://link.springer.com/article/10.1134/S1061934824701223","RegionNum":4,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

摘要

在一次国际实验中,对含有两种不同铀同位素组成的铀材料微粒的样品进行了分析。对25个粒子的质谱分析显示,在测量误差范围内,6个粒子的同位素组成与第一种物质一致,3个粒子与第二种物质一致。然而,其余16个粒子的铀同位素组成与这两种已知物质都不匹配。这表明用扫描电子显微镜对铀微粒进行初步检测,可以识别携带源物质同位素组成信息的微粒。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Use of Scanning Electron Microscopy to Enhance the Accuracy of Mass Spectrometry Analysis of Uranium Microparticles

Use of Scanning Electron Microscopy to Enhance the Accuracy of Mass Spectrometry Analysis of Uranium Microparticles

A sample containing microparticles of two different uranium materials with distinct uranium isotopic compositions was analyzed during an international experiment. Mass spectrometric analysis of 25 particles revealed that, within the measurement error, six particles had an isotopic composition consistent with that of the first material, and three particles were consistent with the second material. However, the uranium isotopic composition of the remaining 16 particles did not match either of the known materials. This indicates that the preliminary examination of uranium microparticles by scanning electron microscopy can identify particles carrying information about the isotopic composition of the source materials.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Analytical Chemistry
Journal of Analytical Chemistry 化学-分析化学
CiteScore
2.10
自引率
9.10%
发文量
146
审稿时长
13 months
期刊介绍: The Journal of Analytical Chemistry is an international peer reviewed journal that covers theoretical and applied aspects of analytical chemistry; it informs the reader about new achievements in analytical methods, instruments and reagents. Ample space is devoted to problems arising in the analysis of vital media such as water and air. Consideration is given to the detection and determination of metal ions, anions, and various organic substances. The journal welcomes manuscripts from all countries in the English or Russian language.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信