电感耦合等离子体质谱测定关键血清矿物质的性能:与标准定量方法的比较研究。

IF 2.6 4区 医学 Q2 MEDICAL LABORATORY TECHNOLOGY
Journal of Clinical Laboratory Analysis Pub Date : 2025-01-01 Epub Date: 2024-12-23 DOI:10.1002/jcla.25140
Kosuke Kojo, Tomoko Oguri, Takazo Tanaka, Atsushi Ikeda, Takuya Shimizu, Shunsuke Fujimoto, Ayumi Nakazono, Yoshiyuki Nagumo, Shuya Kandori, Hiromitsu Negoro, Hiroyuki Nishiyama
{"title":"电感耦合等离子体质谱测定关键血清矿物质的性能:与标准定量方法的比较研究。","authors":"Kosuke Kojo, Tomoko Oguri, Takazo Tanaka, Atsushi Ikeda, Takuya Shimizu, Shunsuke Fujimoto, Ayumi Nakazono, Yoshiyuki Nagumo, Shuya Kandori, Hiromitsu Negoro, Hiroyuki Nishiyama","doi":"10.1002/jcla.25140","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Inductively coupled plasma mass spectrometry (ICP-MS) is widely used for the accurate measurement of minerals. However, its application to serum essential mineral measurement has not been fully evaluated. The present study aimed to assess the performance of ICP-MS for serum minerals by comparing its measurements to those obtained using standard quantification methods.</p><p><strong>Methods: </strong>Cross-sectional data were collected from 282 participants from a single facility in Japan. Serum concentrations of eight key minerals, namely sodium, potassium, calcium, phosphorus, magnesium, iron, zinc, and copper, measured via ICP-MS and standard methods were compared using Passing-Bablok regression and Bland-Altman plots.</p><p><strong>Results: </strong>All minerals, except phosphorus, exhibited good agreement with standard methods, with more stable regression coefficients observed for minerals with greater interindividual variability. After systematically filtering outliers, the mean relative errors were approximately -3% for sodium, potassium, calcium, and magnesium; +5% for iron; 0% for zinc; and -19% for copper. The outliers for iron were primarily due to mild hemolysis, whereas those for zinc were largely attributed to nonhemolysis factors. For phosphorus, the serum total phosphorus concentration measured using ICP-MS was approximately 3.5 times higher than the serum inorganic phosphorus concentration measured using standard methods, with a weak correlation observed between the two methods.</p><p><strong>Conclusion: </strong>This study provides a practical foundation for future research. Understanding ICP-MS characteristics will facilitate the development of new approaches in clinical diagnostics.</p>","PeriodicalId":15509,"journal":{"name":"Journal of Clinical Laboratory Analysis","volume":" ","pages":"e25140"},"PeriodicalIF":2.6000,"publicationDate":"2025-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Inductively Coupled Plasma Mass Spectrometry Performance for the Measurement of Key Serum Minerals: A Comparative Study With Standard Quantification Methods.\",\"authors\":\"Kosuke Kojo, Tomoko Oguri, Takazo Tanaka, Atsushi Ikeda, Takuya Shimizu, Shunsuke Fujimoto, Ayumi Nakazono, Yoshiyuki Nagumo, Shuya Kandori, Hiromitsu Negoro, Hiroyuki Nishiyama\",\"doi\":\"10.1002/jcla.25140\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Inductively coupled plasma mass spectrometry (ICP-MS) is widely used for the accurate measurement of minerals. However, its application to serum essential mineral measurement has not been fully evaluated. The present study aimed to assess the performance of ICP-MS for serum minerals by comparing its measurements to those obtained using standard quantification methods.</p><p><strong>Methods: </strong>Cross-sectional data were collected from 282 participants from a single facility in Japan. Serum concentrations of eight key minerals, namely sodium, potassium, calcium, phosphorus, magnesium, iron, zinc, and copper, measured via ICP-MS and standard methods were compared using Passing-Bablok regression and Bland-Altman plots.</p><p><strong>Results: </strong>All minerals, except phosphorus, exhibited good agreement with standard methods, with more stable regression coefficients observed for minerals with greater interindividual variability. After systematically filtering outliers, the mean relative errors were approximately -3% for sodium, potassium, calcium, and magnesium; +5% for iron; 0% for zinc; and -19% for copper. The outliers for iron were primarily due to mild hemolysis, whereas those for zinc were largely attributed to nonhemolysis factors. For phosphorus, the serum total phosphorus concentration measured using ICP-MS was approximately 3.5 times higher than the serum inorganic phosphorus concentration measured using standard methods, with a weak correlation observed between the two methods.</p><p><strong>Conclusion: </strong>This study provides a practical foundation for future research. Understanding ICP-MS characteristics will facilitate the development of new approaches in clinical diagnostics.</p>\",\"PeriodicalId\":15509,\"journal\":{\"name\":\"Journal of Clinical Laboratory Analysis\",\"volume\":\" \",\"pages\":\"e25140\"},\"PeriodicalIF\":2.6000,\"publicationDate\":\"2025-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Clinical Laboratory Analysis\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1002/jcla.25140\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/12/23 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"MEDICAL LABORATORY TECHNOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Clinical Laboratory Analysis","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1002/jcla.25140","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/12/23 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"MEDICAL LABORATORY TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

背景:电感耦合等离子体质谱法(ICP-MS)广泛用于矿物的精确测定。然而,其在血清必需矿物质测量中的应用尚未得到充分评价。本研究旨在通过比较ICP-MS测定血清矿物质的结果与使用标准定量方法获得的结果来评估ICP-MS测定血清矿物质的性能。方法:横断面数据收集282名参与者从一个单一的机构在日本。采用ICP-MS法和标准法测定血清中钠、钾、钙、磷、镁、铁、锌、铜等8种关键矿物质浓度,采用pass - bablok回归法和Bland-Altman图进行比较。结果:除磷外,所有矿物的回归系数与标准方法吻合良好,个体间差异较大的矿物回归系数更为稳定。在系统地过滤异常值后,钠、钾、钙和镁的平均相对误差约为-3%;铁+5%;锌为0%;铜的-19%。铁的异常值主要是由于轻度溶血,而锌的异常值主要归因于非溶血因素。对于磷,ICP-MS测定的血清总磷浓度约为标准方法测定的血清无机磷浓度的3.5倍,两种方法之间存在弱相关性。结论:本研究为今后的研究提供了实践基础。了解ICP-MS特征将有助于临床诊断新方法的发展。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Inductively Coupled Plasma Mass Spectrometry Performance for the Measurement of Key Serum Minerals: A Comparative Study With Standard Quantification Methods.

Background: Inductively coupled plasma mass spectrometry (ICP-MS) is widely used for the accurate measurement of minerals. However, its application to serum essential mineral measurement has not been fully evaluated. The present study aimed to assess the performance of ICP-MS for serum minerals by comparing its measurements to those obtained using standard quantification methods.

Methods: Cross-sectional data were collected from 282 participants from a single facility in Japan. Serum concentrations of eight key minerals, namely sodium, potassium, calcium, phosphorus, magnesium, iron, zinc, and copper, measured via ICP-MS and standard methods were compared using Passing-Bablok regression and Bland-Altman plots.

Results: All minerals, except phosphorus, exhibited good agreement with standard methods, with more stable regression coefficients observed for minerals with greater interindividual variability. After systematically filtering outliers, the mean relative errors were approximately -3% for sodium, potassium, calcium, and magnesium; +5% for iron; 0% for zinc; and -19% for copper. The outliers for iron were primarily due to mild hemolysis, whereas those for zinc were largely attributed to nonhemolysis factors. For phosphorus, the serum total phosphorus concentration measured using ICP-MS was approximately 3.5 times higher than the serum inorganic phosphorus concentration measured using standard methods, with a weak correlation observed between the two methods.

Conclusion: This study provides a practical foundation for future research. Understanding ICP-MS characteristics will facilitate the development of new approaches in clinical diagnostics.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Clinical Laboratory Analysis
Journal of Clinical Laboratory Analysis 医学-医学实验技术
CiteScore
5.60
自引率
7.40%
发文量
584
审稿时长
6-12 weeks
期刊介绍: Journal of Clinical Laboratory Analysis publishes original articles on newly developing modes of technology and laboratory assays, with emphasis on their application in current and future clinical laboratory testing. This includes reports from the following fields: immunochemistry and toxicology, hematology and hematopathology, immunopathology, molecular diagnostics, microbiology, genetic testing, immunohematology, and clinical chemistry.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信