测量:用SPLINT技术保证被拉伸阴茎长度的观察者内部和观察者之间的可靠性。

Q3 Medicine
Prabudh Goel, Prativa Choudhury, Vivek Verma, Shivani Phugat, Mani Kalaivani, Teg Rabab Singh, Kanika Sharma, Vishesh Jain, Devendra Kumar Yadav, Anjan Kumar Dhua, Sandeep Agarwala
{"title":"测量:用SPLINT技术保证被拉伸阴茎长度的观察者内部和观察者之间的可靠性。","authors":"Prabudh Goel, Prativa Choudhury, Vivek Verma, Shivani Phugat, Mani Kalaivani, Teg Rabab Singh, Kanika Sharma, Vishesh Jain, Devendra Kumar Yadav, Anjan Kumar Dhua, Sandeep Agarwala","doi":"10.4103/jiaps.jiaps_107_24","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>A discrepancy between the true and measured value of stretched penile length (SPL) may be a result of errors that can either be systematic or random. Hence, it becomes important to focus on the quality of measurements to prevent any iatrogenic harm to the patients.</p><p><strong>Objective: </strong>The objective of this study was to assess the magnitude of intra- and interobserver variations in the measurement of SPL with the SPLINT technique.</p><p><strong>Materials and methods: </strong>SPL was measured prospectively in a cohort of 449 boys aged 0-14 years including 68 infants (substratified into Group I: >4 years, Group II: 4-8 years, and Group III: >8 years) with the SPLINT technique by expert (E: E1 and E2) and trainee (T: T1 and T2) surgeons after completing a three-tiered training module. Intra- and interobserver variability was assessed through descriptive statistics, intraclass correlation (ICC), relative technical error of measurement (rTEM), and reliability or <i>R</i> (%).</p><p><strong>Results: </strong>Intraobserver variability: the mean difference between the two readings (E1 and E2) is 0.08 cm (95% confidence interval [CI]: 0.073-0.087), ICC was 0.998 (95% CI: 0.997-0.998), and intraobserver variability ≤0.1 cm in 85% of the participants (<i>n</i> = 370 of 433). The rTEM and reliability (%) were 1.82% and 98.1% (Group I), 1.65% and 98.9% (Group II), and 1.09% and 99.7% (Group III), respectively. The intraobserver variability was observed to be inversely proportional to the age of the participants (correlation coefficient = -0.56). Interobserver variability was calculated separately for expert versus trainee and trainee versus trainee (T-vs-T) measurements. For expert versus expert, ICC, rTEM, and reliability (%) were 0.984, 2.4%, and 96.8% (Group 1), 0.992, 2.07%, and 98.3% (Group 2), and 0.997, 1.38%, and 99.05% (Group 3), respectively. A similar pattern of variability was observed for T-vs-T measurements. The reliability (%) of the SPL by experts is consistently more than that of trainees across all age groups; however, the difference ameliorates with the age of participant.</p><p><strong>Conclusions: </strong>The study has validated the SPLINT technique by demonstrating a high level of intra- and interobserver reliability. The adequacy of the training modules for SPL measurements described in this study has also been established. Evidence that the SPL can be used as an objective marker of penile dimensions is herewith furnished.</p>","PeriodicalId":16069,"journal":{"name":"Journal of Indian Association of Pediatric Surgeons","volume":"29 6","pages":"579-588"},"PeriodicalIF":0.0000,"publicationDate":"2024-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11649040/pdf/","citationCount":"0","resultStr":"{\"title\":\"Measuring up: Ensuring Intra- and Interobserver Reliability in Stretched Penile Length with the SPLINT Technique.\",\"authors\":\"Prabudh Goel, Prativa Choudhury, Vivek Verma, Shivani Phugat, Mani Kalaivani, Teg Rabab Singh, Kanika Sharma, Vishesh Jain, Devendra Kumar Yadav, Anjan Kumar Dhua, Sandeep Agarwala\",\"doi\":\"10.4103/jiaps.jiaps_107_24\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>A discrepancy between the true and measured value of stretched penile length (SPL) may be a result of errors that can either be systematic or random. Hence, it becomes important to focus on the quality of measurements to prevent any iatrogenic harm to the patients.</p><p><strong>Objective: </strong>The objective of this study was to assess the magnitude of intra- and interobserver variations in the measurement of SPL with the SPLINT technique.</p><p><strong>Materials and methods: </strong>SPL was measured prospectively in a cohort of 449 boys aged 0-14 years including 68 infants (substratified into Group I: >4 years, Group II: 4-8 years, and Group III: >8 years) with the SPLINT technique by expert (E: E1 and E2) and trainee (T: T1 and T2) surgeons after completing a three-tiered training module. Intra- and interobserver variability was assessed through descriptive statistics, intraclass correlation (ICC), relative technical error of measurement (rTEM), and reliability or <i>R</i> (%).</p><p><strong>Results: </strong>Intraobserver variability: the mean difference between the two readings (E1 and E2) is 0.08 cm (95% confidence interval [CI]: 0.073-0.087), ICC was 0.998 (95% CI: 0.997-0.998), and intraobserver variability ≤0.1 cm in 85% of the participants (<i>n</i> = 370 of 433). The rTEM and reliability (%) were 1.82% and 98.1% (Group I), 1.65% and 98.9% (Group II), and 1.09% and 99.7% (Group III), respectively. The intraobserver variability was observed to be inversely proportional to the age of the participants (correlation coefficient = -0.56). Interobserver variability was calculated separately for expert versus trainee and trainee versus trainee (T-vs-T) measurements. For expert versus expert, ICC, rTEM, and reliability (%) were 0.984, 2.4%, and 96.8% (Group 1), 0.992, 2.07%, and 98.3% (Group 2), and 0.997, 1.38%, and 99.05% (Group 3), respectively. A similar pattern of variability was observed for T-vs-T measurements. The reliability (%) of the SPL by experts is consistently more than that of trainees across all age groups; however, the difference ameliorates with the age of participant.</p><p><strong>Conclusions: </strong>The study has validated the SPLINT technique by demonstrating a high level of intra- and interobserver reliability. The adequacy of the training modules for SPL measurements described in this study has also been established. Evidence that the SPL can be used as an objective marker of penile dimensions is herewith furnished.</p>\",\"PeriodicalId\":16069,\"journal\":{\"name\":\"Journal of Indian Association of Pediatric Surgeons\",\"volume\":\"29 6\",\"pages\":\"579-588\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11649040/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Indian Association of Pediatric Surgeons\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4103/jiaps.jiaps_107_24\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/11/5 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Indian Association of Pediatric Surgeons","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/jiaps.jiaps_107_24","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/11/5 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

摘要

背景:拉伸阴茎长度(SPL)的真实值与实测值之间的差异可能是系统误差或随机误差的结果。因此,关注测量的质量以防止对患者的任何医源性伤害变得非常重要。目的:本研究的目的是评估SPLINT技术测量SPL时观察者内部和观察者之间的变化幅度。材料和方法:在完成三级培训模块后,由专家(E: E1和E2)和实习医生(T: T1和T2)采用SPLINT技术对449名0-14岁的男孩进行前瞻性SPL测量,其中包括68名婴儿(亚分层为I组:>4岁,II组:4-8岁,III组:>8岁)。通过描述性统计、类内相关性(ICC)、相对测量技术误差(rTEM)和信度R(%)来评估观察者内部和观察者之间的变异性。结果:观察者内变异性:两个读数(E1和E2)之间的平均差异为0.08 cm(95%可信区间[CI]: 0.073-0.087), ICC为0.998 (95% CI: 0.997-0.998), 85%的参与者(n = 370 / 433)的观察者内变异性≤0.1 cm。rTEM和信度(%)分别为1.82%和98.1%(第一组),1.65%和98.9%(第二组),1.09%和99.7%(第三组)。观察到观察者内部变异与参与者的年龄成反比(相关系数= -0.56)。观察者之间的可变性分别计算专家对受训人员和受训人员对受训人员(T-vs-T)测量。对于专家对专家,ICC、rTEM和信度(%)分别为0.984、2.4%和96.8%(组1),0.992、2.07%和98.3%(组2),0.997、1.38%和99.05%(组3)。在T-vs-T测量中观察到类似的变异性模式。在所有年龄组中,专家对SPL的信度(%)始终高于受训人员;然而,这种差异随着参与者年龄的增长而减小。结论:该研究通过展示高水平的观察者内部和观察者之间的可靠性,验证了SPLINT技术。本研究中描述的SPL测量训练模块的充分性也已确定。有证据表明SPL可以作为阴茎尺寸的客观标记。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Measuring up: Ensuring Intra- and Interobserver Reliability in Stretched Penile Length with the SPLINT Technique.

Background: A discrepancy between the true and measured value of stretched penile length (SPL) may be a result of errors that can either be systematic or random. Hence, it becomes important to focus on the quality of measurements to prevent any iatrogenic harm to the patients.

Objective: The objective of this study was to assess the magnitude of intra- and interobserver variations in the measurement of SPL with the SPLINT technique.

Materials and methods: SPL was measured prospectively in a cohort of 449 boys aged 0-14 years including 68 infants (substratified into Group I: >4 years, Group II: 4-8 years, and Group III: >8 years) with the SPLINT technique by expert (E: E1 and E2) and trainee (T: T1 and T2) surgeons after completing a three-tiered training module. Intra- and interobserver variability was assessed through descriptive statistics, intraclass correlation (ICC), relative technical error of measurement (rTEM), and reliability or R (%).

Results: Intraobserver variability: the mean difference between the two readings (E1 and E2) is 0.08 cm (95% confidence interval [CI]: 0.073-0.087), ICC was 0.998 (95% CI: 0.997-0.998), and intraobserver variability ≤0.1 cm in 85% of the participants (n = 370 of 433). The rTEM and reliability (%) were 1.82% and 98.1% (Group I), 1.65% and 98.9% (Group II), and 1.09% and 99.7% (Group III), respectively. The intraobserver variability was observed to be inversely proportional to the age of the participants (correlation coefficient = -0.56). Interobserver variability was calculated separately for expert versus trainee and trainee versus trainee (T-vs-T) measurements. For expert versus expert, ICC, rTEM, and reliability (%) were 0.984, 2.4%, and 96.8% (Group 1), 0.992, 2.07%, and 98.3% (Group 2), and 0.997, 1.38%, and 99.05% (Group 3), respectively. A similar pattern of variability was observed for T-vs-T measurements. The reliability (%) of the SPL by experts is consistently more than that of trainees across all age groups; however, the difference ameliorates with the age of participant.

Conclusions: The study has validated the SPLINT technique by demonstrating a high level of intra- and interobserver reliability. The adequacy of the training modules for SPL measurements described in this study has also been established. Evidence that the SPL can be used as an objective marker of penile dimensions is herewith furnished.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Indian Association of Pediatric Surgeons
Journal of Indian Association of Pediatric Surgeons Medicine-Pediatrics, Perinatology and Child Health
CiteScore
0.80
自引率
0.00%
发文量
148
审稿时长
30 weeks
期刊介绍: Journal of Indian Association of Pediatric Surgeons is the official organ of Indian Association of Pediatric Surgeons. The journal started its journey in October 1995 under the Editor-in-Chief Prof. Subir K Chatterjee. An advisory board was formed with well-versed internationally reputed senior members of our society like Late Prof. R K Gandhi, Prof. I C Pathak, Prof. P Upadhyay, Prof. T Dorairajan and many more. since then the journal is published quarterly uninterrupted. The journal publishes original articles, case reports, review articles and technical innovations. Special issues on different subjects are published every year. There have been several contributions from overseas experts.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信