直接肺超声评价(CLUE)技术监测猪肺血管外肺水的可行性和准确性。

IF 3.1 2区 医学 Q2 CARDIAC & CARDIOVASCULAR SYSTEMS
Sana N Buttar, Hasse Møller-Sørensen, Michael Perch, Rene H Petersen, Christian H Møller
{"title":"直接肺超声评价(CLUE)技术监测猪肺血管外肺水的可行性和准确性。","authors":"Sana N Buttar, Hasse Møller-Sørensen, Michael Perch, Rene H Petersen, Christian H Møller","doi":"10.1093/ejcts/ezae428","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>Extravascular lung water precedes deterioration of pulmonary function. Current tools to assess extravascular lung water in a setting of donor lung procurement and ex vivo lung perfusion (EVLP) are either subjective or not feasible. Therefore, a direCt Lung Ultrasound Evaluation (CLUE) has been introduced. This study reassesses the feasibility and accuracy of CLUE by measuring its correlation with lung weight, wet-to-dry ratio (W/D ratio), dynamic compliance and pulmonary vascular resistance (PVR) in a porcine model.</p><p><strong>Methods: </strong>CLUE images, lung weight, dynamic compliance and PVR were recorded and lung samples for W/D ratio were taken before and after EVLP. CLUE score was calculated based on B-lines on images taken at each point of the lung using an established equation.</p><p><strong>Results: </strong>Eighteen porcine lungs were included. Total median of CLUE score, lung weight, W/D ratio and PVR increased significantly, while median of dynamic compliance decreased significantly after EVLP. Total median CLUE score increased significantly in all four surfaces after EVLP with equally high CLUE scores in posterior and diaphragm lines. CLUE score demonstrated a significant strong positive correlation with lung weight (r = 0.825) and W/D ratio (r = 0.837), while CLUE's correlation with dynamic compliance and PVR was significantly moderate to strong (r = -0.669, r = 0.695, respectively).</p><p><strong>Conclusions: </strong>CLUE technique is feasible to assess extravascular lung water in donor lungs after procurement and during EVLP. CLUE score correlated significantly with lung weight, W/D ratio, dynamic compliance and PVR. Transplant suitability of a donor lung may not solely depend on CLUE evaluation.</p>","PeriodicalId":11938,"journal":{"name":"European Journal of Cardio-Thoracic Surgery","volume":" ","pages":""},"PeriodicalIF":3.1000,"publicationDate":"2024-12-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11702978/pdf/","citationCount":"0","resultStr":"{\"title\":\"Feasibility and accuracy of DireCt Lung Ultrasound Evaluation technique to monitor extravascular lung water in porcine lungs.\",\"authors\":\"Sana N Buttar, Hasse Møller-Sørensen, Michael Perch, Rene H Petersen, Christian H Møller\",\"doi\":\"10.1093/ejcts/ezae428\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objectives: </strong>Extravascular lung water precedes deterioration of pulmonary function. Current tools to assess extravascular lung water in a setting of donor lung procurement and ex vivo lung perfusion (EVLP) are either subjective or not feasible. Therefore, a direCt Lung Ultrasound Evaluation (CLUE) has been introduced. This study reassesses the feasibility and accuracy of CLUE by measuring its correlation with lung weight, wet-to-dry ratio (W/D ratio), dynamic compliance and pulmonary vascular resistance (PVR) in a porcine model.</p><p><strong>Methods: </strong>CLUE images, lung weight, dynamic compliance and PVR were recorded and lung samples for W/D ratio were taken before and after EVLP. CLUE score was calculated based on B-lines on images taken at each point of the lung using an established equation.</p><p><strong>Results: </strong>Eighteen porcine lungs were included. Total median of CLUE score, lung weight, W/D ratio and PVR increased significantly, while median of dynamic compliance decreased significantly after EVLP. Total median CLUE score increased significantly in all four surfaces after EVLP with equally high CLUE scores in posterior and diaphragm lines. CLUE score demonstrated a significant strong positive correlation with lung weight (r = 0.825) and W/D ratio (r = 0.837), while CLUE's correlation with dynamic compliance and PVR was significantly moderate to strong (r = -0.669, r = 0.695, respectively).</p><p><strong>Conclusions: </strong>CLUE technique is feasible to assess extravascular lung water in donor lungs after procurement and during EVLP. CLUE score correlated significantly with lung weight, W/D ratio, dynamic compliance and PVR. Transplant suitability of a donor lung may not solely depend on CLUE evaluation.</p>\",\"PeriodicalId\":11938,\"journal\":{\"name\":\"European Journal of Cardio-Thoracic Surgery\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":3.1000,\"publicationDate\":\"2024-12-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11702978/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"European Journal of Cardio-Thoracic Surgery\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1093/ejcts/ezae428\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Journal of Cardio-Thoracic Surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1093/ejcts/ezae428","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

摘要

目的:肺血管外水(EVLW)先于肺功能恶化。目前评估供肺获取和体外肺灌注(EVLP)情况下EVLW的工具要么是主观的,要么是不可行的。因此,引入了直接肺超声评估(CLUE)。本研究通过测量CLUE与猪肺重、湿干比(W/D ratio)、动态顺应性和肺血管阻力(PVR)的相关性,重新评估CLUE的可行性和准确性。方法:记录肺活量、肺质量、动态顺应性、肺容积比(PVR),并取肺活量/密度比(W/D)肺标本。CLUE评分基于肺各点图像的b线,使用已建立的方程计算。结果:共纳入18只猪肺。EVLP后CLUE评分、肺重、W/D比、PVR的总中位数显著升高,动态顺应性中位数显著降低。EVLP后四个表面的CLUE总中位评分显著增加,其中后膈线的CLUE评分同样高。CLUE评分与肺重(r= 0.825)、W/D比(r= 0.837)呈显著强正相关,与动态顺应性、PVR呈显著中强相关(r= - 0.669、r= 0.695)。结论:CLUE技术可用于供体肺活量的评估。CLUE评分与肺重、W/D比、动态顺应性、PVR显著相关。供体肺的移植适宜性可能不仅仅取决于CLUE评估。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Feasibility and accuracy of DireCt Lung Ultrasound Evaluation technique to monitor extravascular lung water in porcine lungs.

Objectives: Extravascular lung water precedes deterioration of pulmonary function. Current tools to assess extravascular lung water in a setting of donor lung procurement and ex vivo lung perfusion (EVLP) are either subjective or not feasible. Therefore, a direCt Lung Ultrasound Evaluation (CLUE) has been introduced. This study reassesses the feasibility and accuracy of CLUE by measuring its correlation with lung weight, wet-to-dry ratio (W/D ratio), dynamic compliance and pulmonary vascular resistance (PVR) in a porcine model.

Methods: CLUE images, lung weight, dynamic compliance and PVR were recorded and lung samples for W/D ratio were taken before and after EVLP. CLUE score was calculated based on B-lines on images taken at each point of the lung using an established equation.

Results: Eighteen porcine lungs were included. Total median of CLUE score, lung weight, W/D ratio and PVR increased significantly, while median of dynamic compliance decreased significantly after EVLP. Total median CLUE score increased significantly in all four surfaces after EVLP with equally high CLUE scores in posterior and diaphragm lines. CLUE score demonstrated a significant strong positive correlation with lung weight (r = 0.825) and W/D ratio (r = 0.837), while CLUE's correlation with dynamic compliance and PVR was significantly moderate to strong (r = -0.669, r = 0.695, respectively).

Conclusions: CLUE technique is feasible to assess extravascular lung water in donor lungs after procurement and during EVLP. CLUE score correlated significantly with lung weight, W/D ratio, dynamic compliance and PVR. Transplant suitability of a donor lung may not solely depend on CLUE evaluation.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
5.60
自引率
11.80%
发文量
564
审稿时长
2 months
期刊介绍: The primary aim of the European Journal of Cardio-Thoracic Surgery is to provide a medium for the publication of high-quality original scientific reports documenting progress in cardiac and thoracic surgery. The journal publishes reports of significant clinical and experimental advances related to surgery of the heart, the great vessels and the chest. The European Journal of Cardio-Thoracic Surgery is an international journal and accepts submissions from all regions. The journal is supported by a number of leading European societies.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信