经导管肺动脉脱带术:对每个病人都有效吗?

IF 0.5 4区 医学 Q4 SURGERY
İbrahim Halil Demir, Dursun Muhammed Özdemir, Selma Oktay Ergin, İlker Kemal Yücel, Murat Sürücü, Murat Çiçek, Numan Ali Aydemir, Ahmet Çelebi
{"title":"经导管肺动脉脱带术:对每个病人都有效吗?","authors":"İbrahim Halil Demir, Dursun Muhammed Özdemir, Selma Oktay Ergin, İlker Kemal Yücel, Murat Sürücü, Murat Çiçek, Numan Ali Aydemir, Ahmet Çelebi","doi":"10.5606/tgkdc.dergisi.2024.26234","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>This study aimed to present our experience with transcatheter pulmonary debanding, focusing on patient outcomes.</p><p><strong>Methods: </strong>The retrospective study was conducted with 32 patients (17 males, 15 females; mean age: 3.6±2 years; range, 0.5 to 8.8 years) who underwent transcatheter pulmonary debanding between January 2010 and January 2024. The patients were evaluated in two groups. In Group 1 (n=24), total debanding was targeted for patients with spontaneously closed or restrictive ventricular septal defects or those suitable for transcatheter ventricular septal defect closure. In Group 2 (n=8), palliative debanding was utilized in children with ongoing band requirement.</p><p><strong>Results: </strong>The median body weight was 15 kg. In Group 1, the mean right ventricle-to-aortic pressure ratio (RVp/Aop) was 0.91±0.21 before the procedure, which decreased to a mean of 0.33±0.20 after the procedure. In Group 2, the mean RVp/Aop was 1.31±0.47, which decreased to 0.77±0.13 after transcatheter palliative debanding. The mean peripheral oxygen saturation was 80±6% before the procedure and 94±2.5% after the procedure. Transcatheter debanding was successful in all patients when surgical pulmonary banding was performed with 6-0 Prolene and polytetrafluoroethylene band material.</p><p><strong>Conclusion: </strong>Transcatheter banding is a safe and effective procedure that minimizes the need for reoperation.</p>","PeriodicalId":49413,"journal":{"name":"Turk Gogus Kalp Damar Cerrahisi Dergisi-Turkish Journal of Thoracic and Cardiovascular Surgery","volume":"32 4","pages":"367-377"},"PeriodicalIF":0.5000,"publicationDate":"2024-10-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11620524/pdf/","citationCount":"0","resultStr":"{\"title\":\"Transcatheter pulmonary artery debanding: Is it effective in every patient?\",\"authors\":\"İbrahim Halil Demir, Dursun Muhammed Özdemir, Selma Oktay Ergin, İlker Kemal Yücel, Murat Sürücü, Murat Çiçek, Numan Ali Aydemir, Ahmet Çelebi\",\"doi\":\"10.5606/tgkdc.dergisi.2024.26234\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>This study aimed to present our experience with transcatheter pulmonary debanding, focusing on patient outcomes.</p><p><strong>Methods: </strong>The retrospective study was conducted with 32 patients (17 males, 15 females; mean age: 3.6±2 years; range, 0.5 to 8.8 years) who underwent transcatheter pulmonary debanding between January 2010 and January 2024. The patients were evaluated in two groups. In Group 1 (n=24), total debanding was targeted for patients with spontaneously closed or restrictive ventricular septal defects or those suitable for transcatheter ventricular septal defect closure. In Group 2 (n=8), palliative debanding was utilized in children with ongoing band requirement.</p><p><strong>Results: </strong>The median body weight was 15 kg. In Group 1, the mean right ventricle-to-aortic pressure ratio (RVp/Aop) was 0.91±0.21 before the procedure, which decreased to a mean of 0.33±0.20 after the procedure. In Group 2, the mean RVp/Aop was 1.31±0.47, which decreased to 0.77±0.13 after transcatheter palliative debanding. The mean peripheral oxygen saturation was 80±6% before the procedure and 94±2.5% after the procedure. Transcatheter debanding was successful in all patients when surgical pulmonary banding was performed with 6-0 Prolene and polytetrafluoroethylene band material.</p><p><strong>Conclusion: </strong>Transcatheter banding is a safe and effective procedure that minimizes the need for reoperation.</p>\",\"PeriodicalId\":49413,\"journal\":{\"name\":\"Turk Gogus Kalp Damar Cerrahisi Dergisi-Turkish Journal of Thoracic and Cardiovascular Surgery\",\"volume\":\"32 4\",\"pages\":\"367-377\"},\"PeriodicalIF\":0.5000,\"publicationDate\":\"2024-10-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11620524/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Turk Gogus Kalp Damar Cerrahisi Dergisi-Turkish Journal of Thoracic and Cardiovascular Surgery\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.5606/tgkdc.dergisi.2024.26234\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/10/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q4\",\"JCRName\":\"SURGERY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Turk Gogus Kalp Damar Cerrahisi Dergisi-Turkish Journal of Thoracic and Cardiovascular Surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.5606/tgkdc.dergisi.2024.26234","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/10/1 0:00:00","PubModel":"eCollection","JCR":"Q4","JCRName":"SURGERY","Score":null,"Total":0}
引用次数: 0

摘要

背景:本研究旨在介绍经导管肺去带术的经验,重点关注患者的预后。方法:对32例患者进行回顾性研究,其中男17例,女15例;平均年龄:3.6±2岁;在2010年1月至2024年1月期间接受了经导管肺去带手术的患者。患者分为两组进行评估。在第1组(n=24)中,针对自发性闭合性或限制性室间隔缺损患者或适合经导管室间隔缺损闭合术的患者进行完全去条带。在第2组(n=8)中,对持续有绑带需求的儿童使用姑息性绑带。结果:中位体重为15 kg。1组患者术前右心室-主动脉压比(RVp/Aop)均值为0.91±0.21,术后降至0.33±0.20。2组平均RVp/Aop为1.31±0.47,经导管姑息性去带后RVp/Aop降至0.77±0.13。术前平均外周血氧饱和度80±6%,术后平均外周血氧饱和度94±2.5%。当使用6-0丙烯和聚四氟乙烯带材料进行外科肺束带时,所有患者经导管脱带均成功。结论:经导管捆扎术是一种安全有效的手术方法,可减少再次手术的需要。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Transcatheter pulmonary artery debanding: Is it effective in every patient?

Background: This study aimed to present our experience with transcatheter pulmonary debanding, focusing on patient outcomes.

Methods: The retrospective study was conducted with 32 patients (17 males, 15 females; mean age: 3.6±2 years; range, 0.5 to 8.8 years) who underwent transcatheter pulmonary debanding between January 2010 and January 2024. The patients were evaluated in two groups. In Group 1 (n=24), total debanding was targeted for patients with spontaneously closed or restrictive ventricular septal defects or those suitable for transcatheter ventricular septal defect closure. In Group 2 (n=8), palliative debanding was utilized in children with ongoing band requirement.

Results: The median body weight was 15 kg. In Group 1, the mean right ventricle-to-aortic pressure ratio (RVp/Aop) was 0.91±0.21 before the procedure, which decreased to a mean of 0.33±0.20 after the procedure. In Group 2, the mean RVp/Aop was 1.31±0.47, which decreased to 0.77±0.13 after transcatheter palliative debanding. The mean peripheral oxygen saturation was 80±6% before the procedure and 94±2.5% after the procedure. Transcatheter debanding was successful in all patients when surgical pulmonary banding was performed with 6-0 Prolene and polytetrafluoroethylene band material.

Conclusion: Transcatheter banding is a safe and effective procedure that minimizes the need for reoperation.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
1.00
自引率
0.00%
发文量
98
审稿时长
3-8 weeks
期刊介绍: The Turkish Journal of Thoracic and Cardiovascular Surgery is an international open access journal which publishes original articles on topics in generality of Cardiac, Thoracic, Arterial, Venous, Lymphatic Disorders and their managements. These encompass all relevant clinical, surgical and experimental studies, editorials, current and collective reviews, technical know-how papers, case reports, interesting images, How to Do It papers, correspondences, and commentaries.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信