桡骨远端骨折外侧与低位背板固定的并发症。

IF 2.6 2区 医学 Q1 ORTHOPEDICS
Eric X Jiang, Charles S Day
{"title":"桡骨远端骨折外侧与低位背板固定的并发症。","authors":"Eric X Jiang, Charles S Day","doi":"10.5435/JAAOS-D-23-01169","DOIUrl":null,"url":null,"abstract":"<p><p>Distal radius fractures are one of the most common injuries of the upper extremity. Although nonsurgical management is common, surgical intervention, particularly using volar and dorsal plate fixation, is essential in a subset of injuries. Historically, dorsal plates were avoided due to a high rate of extensor tendon irritation and rupture. Volar locking plates were developed in the early 1990s and first published in 2000 to avoid the complications associated with dorsal plating and have since become widely considered the workhorse for most distal radius fractures. Despite advancements, both fixation methods are still associated with complications, warranting careful selection based on fracture patterns. The purpose of this review is to summarize the most recent literature on the complications associated with the use of volar and low-profile dorsal distal radius plates.</p>","PeriodicalId":51098,"journal":{"name":"Journal of the American Academy of Orthopaedic Surgeons","volume":" ","pages":""},"PeriodicalIF":2.6000,"publicationDate":"2024-11-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Complications of Volar Versus Low-Profile Dorsal Plating of Distal Radius Fractures.\",\"authors\":\"Eric X Jiang, Charles S Day\",\"doi\":\"10.5435/JAAOS-D-23-01169\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Distal radius fractures are one of the most common injuries of the upper extremity. Although nonsurgical management is common, surgical intervention, particularly using volar and dorsal plate fixation, is essential in a subset of injuries. Historically, dorsal plates were avoided due to a high rate of extensor tendon irritation and rupture. Volar locking plates were developed in the early 1990s and first published in 2000 to avoid the complications associated with dorsal plating and have since become widely considered the workhorse for most distal radius fractures. Despite advancements, both fixation methods are still associated with complications, warranting careful selection based on fracture patterns. The purpose of this review is to summarize the most recent literature on the complications associated with the use of volar and low-profile dorsal distal radius plates.</p>\",\"PeriodicalId\":51098,\"journal\":{\"name\":\"Journal of the American Academy of Orthopaedic Surgeons\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":2.6000,\"publicationDate\":\"2024-11-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of the American Academy of Orthopaedic Surgeons\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.5435/JAAOS-D-23-01169\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"ORTHOPEDICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the American Academy of Orthopaedic Surgeons","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.5435/JAAOS-D-23-01169","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

摘要

桡骨远端骨折是上肢最常见的损伤之一。虽然非手术治疗很常见,但手术干预,尤其是使用背板固定,对于一部分损伤是必不可少的。在历史上,由于伸肌腱刺激和断裂的发生率较高,人们一直避免使用背板。为了避免背板固定带来的并发症,上世纪 90 年代初开发出了桡骨外侧锁定钢板,并于 2000 年首次发表,此后被广泛认为是治疗大多数桡骨远端骨折的主要方法。尽管取得了进步,但这两种固定方法仍与并发症有关,因此需要根据骨折形态谨慎选择。本综述旨在总结与使用桡骨远端背侧钢板和低位背侧钢板相关并发症的最新文献。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Complications of Volar Versus Low-Profile Dorsal Plating of Distal Radius Fractures.

Distal radius fractures are one of the most common injuries of the upper extremity. Although nonsurgical management is common, surgical intervention, particularly using volar and dorsal plate fixation, is essential in a subset of injuries. Historically, dorsal plates were avoided due to a high rate of extensor tendon irritation and rupture. Volar locking plates were developed in the early 1990s and first published in 2000 to avoid the complications associated with dorsal plating and have since become widely considered the workhorse for most distal radius fractures. Despite advancements, both fixation methods are still associated with complications, warranting careful selection based on fracture patterns. The purpose of this review is to summarize the most recent literature on the complications associated with the use of volar and low-profile dorsal distal radius plates.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
6.10
自引率
6.20%
发文量
529
审稿时长
4-8 weeks
期刊介绍: The Journal of the American Academy of Orthopaedic Surgeons was established in the fall of 1993 by the Academy in response to its membership’s demand for a clinical review journal. Two issues were published the first year, followed by six issues yearly from 1994 through 2004. In September 2005, JAAOS began publishing monthly issues. Each issue includes richly illustrated peer-reviewed articles focused on clinical diagnosis and management. Special features in each issue provide commentary on developments in pharmacotherapeutics, materials and techniques, and computer applications.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信