[2022-2023 年天津市 DR 高千伏胸部放射影像质量控制改进效果分析]。

Q3 Medicine
N Wang, L Liu, W Chen, Y Liang, L Huang, D Y Wang
{"title":"[2022-2023 年天津市 DR 高千伏胸部放射影像质量控制改进效果分析]。","authors":"N Wang, L Liu, W Chen, Y Liang, L Huang, D Y Wang","doi":"10.3760/cma.j.cn121094-20231227-00168","DOIUrl":null,"url":null,"abstract":"<p><p><b>Objective:</b> To analyze the main effect of improving the image quality of digital radiography (DR) high kilovoltage chest radiography in Tianjin, and to provide reference for the implementation of quality control work. <b>Methods:</b> In November 2023, the image quality evaluation results of DR high kilovoltage chest radiographs submitted for approval by Tianjin Occupational Health Inspection Institutions from 2022 to 2023 were analyzed. According to the results of the image quality review in 2022, the outstanding problems, causes and improvement plans were summarized, and the contents of the image quality improvement projects in 2023 were determined. χ(2) test was used to compare the evaluation results of DR high kilovoltage chest radiograph image quality and the differences among various specific evaluation indicators before and after the improvement, and to compare the differences of image quality evaluation results among groups participating in different quality control improvement projects after the improvement. <b>Results:</b> Compared with 2022, after the implementation of the quality control improvement projects in 2023, the rate of level 1 film (excellent film) and level 2 film (good film) of DR high kilovoltage chest radiographs increased by 3.7% and 20.0%, respectively, and the rate of level 4 film (waste film) decreased by 30.0%. After the implementation of the improvement projects, the non-conformity rate and the serious non-conformity rate of 7 indicators were significantly reduced (<i>P</i><0.05). The medical institutions participating in the two quality control improvement projects of related training and on-site guidance increased the rate of level 2 film (good film) and decreased the rate of level 4 film (waste film) compared with the medical institutions participating in the one improvement project of related training (χ(2)=14.78, <i>P</i><0.05) . <b>Conclusion:</b> The quality control improvement projects can improve the image quality of Tianjin DR high kilovoltage chest radiography, and the combination of relevant training and on-site guidance may have better improvement effect.</p>","PeriodicalId":23958,"journal":{"name":"中华劳动卫生职业病杂志","volume":"42 11","pages":"852-857"},"PeriodicalIF":0.0000,"publicationDate":"2024-11-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"[Analysis of the improvement effect of DR high kilovoltage chest radiography image quality control in Tianjin City from 2022 to 2023].\",\"authors\":\"N Wang, L Liu, W Chen, Y Liang, L Huang, D Y Wang\",\"doi\":\"10.3760/cma.j.cn121094-20231227-00168\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p><b>Objective:</b> To analyze the main effect of improving the image quality of digital radiography (DR) high kilovoltage chest radiography in Tianjin, and to provide reference for the implementation of quality control work. <b>Methods:</b> In November 2023, the image quality evaluation results of DR high kilovoltage chest radiographs submitted for approval by Tianjin Occupational Health Inspection Institutions from 2022 to 2023 were analyzed. According to the results of the image quality review in 2022, the outstanding problems, causes and improvement plans were summarized, and the contents of the image quality improvement projects in 2023 were determined. χ(2) test was used to compare the evaluation results of DR high kilovoltage chest radiograph image quality and the differences among various specific evaluation indicators before and after the improvement, and to compare the differences of image quality evaluation results among groups participating in different quality control improvement projects after the improvement. <b>Results:</b> Compared with 2022, after the implementation of the quality control improvement projects in 2023, the rate of level 1 film (excellent film) and level 2 film (good film) of DR high kilovoltage chest radiographs increased by 3.7% and 20.0%, respectively, and the rate of level 4 film (waste film) decreased by 30.0%. After the implementation of the improvement projects, the non-conformity rate and the serious non-conformity rate of 7 indicators were significantly reduced (<i>P</i><0.05). The medical institutions participating in the two quality control improvement projects of related training and on-site guidance increased the rate of level 2 film (good film) and decreased the rate of level 4 film (waste film) compared with the medical institutions participating in the one improvement project of related training (χ(2)=14.78, <i>P</i><0.05) . <b>Conclusion:</b> The quality control improvement projects can improve the image quality of Tianjin DR high kilovoltage chest radiography, and the combination of relevant training and on-site guidance may have better improvement effect.</p>\",\"PeriodicalId\":23958,\"journal\":{\"name\":\"中华劳动卫生职业病杂志\",\"volume\":\"42 11\",\"pages\":\"852-857\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-11-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"中华劳动卫生职业病杂志\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.3760/cma.j.cn121094-20231227-00168\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"中华劳动卫生职业病杂志","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3760/cma.j.cn121094-20231227-00168","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

摘要

目的分析提高天津市数字X线摄影(DR)高千伏胸片成像质量的主要效果,为质量控制工作的实施提供参考。方法:2023年11月,对2022年至2023年天津市职业健康检查机构报批的DR高千伏胸片图像质量评价结果进行分析。根据 2022 年影像质量评审结果,总结存在的突出问题、原因及改进方案,确定 2023 年影像质量改进项目内容。采用χ(2)检验比较改进前后DR高千伏胸片影像质量评价结果及各具体评价指标间的差异,并比较改进后参加不同质控改进项目组间影像质量评价结果的差异。结果显示与2022年相比,2023年实施质控改进项目后,DR高千伏胸片一级片(优片)和二级片(良片)率分别提高了3.7%和20.0%,四级片(废片)率降低了30.0%。实施改进项目后,7 项指标的不符合率和严重不符合率明显降低(PPC 结论:质控改进项目可以提高天津 DR 高千伏胸片的影像质量,相关培训与现场指导相结合,可能会有更好的改进效果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
[Analysis of the improvement effect of DR high kilovoltage chest radiography image quality control in Tianjin City from 2022 to 2023].

Objective: To analyze the main effect of improving the image quality of digital radiography (DR) high kilovoltage chest radiography in Tianjin, and to provide reference for the implementation of quality control work. Methods: In November 2023, the image quality evaluation results of DR high kilovoltage chest radiographs submitted for approval by Tianjin Occupational Health Inspection Institutions from 2022 to 2023 were analyzed. According to the results of the image quality review in 2022, the outstanding problems, causes and improvement plans were summarized, and the contents of the image quality improvement projects in 2023 were determined. χ(2) test was used to compare the evaluation results of DR high kilovoltage chest radiograph image quality and the differences among various specific evaluation indicators before and after the improvement, and to compare the differences of image quality evaluation results among groups participating in different quality control improvement projects after the improvement. Results: Compared with 2022, after the implementation of the quality control improvement projects in 2023, the rate of level 1 film (excellent film) and level 2 film (good film) of DR high kilovoltage chest radiographs increased by 3.7% and 20.0%, respectively, and the rate of level 4 film (waste film) decreased by 30.0%. After the implementation of the improvement projects, the non-conformity rate and the serious non-conformity rate of 7 indicators were significantly reduced (P<0.05). The medical institutions participating in the two quality control improvement projects of related training and on-site guidance increased the rate of level 2 film (good film) and decreased the rate of level 4 film (waste film) compared with the medical institutions participating in the one improvement project of related training (χ(2)=14.78, P<0.05) . Conclusion: The quality control improvement projects can improve the image quality of Tianjin DR high kilovoltage chest radiography, and the combination of relevant training and on-site guidance may have better improvement effect.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
中华劳动卫生职业病杂志
中华劳动卫生职业病杂志 Medicine-Medicine (all)
CiteScore
1.00
自引率
0.00%
发文量
9764
期刊介绍:
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信