超声波评估牙龈发炎时血管对机械压迫的反应

J Woo, O Kripfgans, I-C Wang, A Samal, A R Betancourt, J C Fenno, H-L Chan
{"title":"超声波评估牙龈发炎时血管对机械压迫的反应","authors":"J Woo, O Kripfgans, I-C Wang, A Samal, A R Betancourt, J C Fenno, H-L Chan","doi":"10.1177/00220345241286807","DOIUrl":null,"url":null,"abstract":"<p><p>The aim of this study was to evaluate the gingival vascular response to mechanical compression during inflammation using ultrasonography. Four female and 4 male Sinclair mini pigs 18 mo of age were included in the study. Pathogenic bacteria-impregnated silk ligatures were placed around the third premolars (PM3), fourth premolars (PM4), and first molars (M1). Ligatures were placed per quadrant at 2-wk intervals in random order. Ultrasonographic study was performed at 2-wk intervals following baseline until the 10th week. Brightness mode (B-mode) images and color flow cine loops were captured at 2 different conditions: 1 with only coupling gel between the ultrasound transducer and the mucosal surface and 1 with the transducer compressing the mucosal surface. The compression was visually adjusted until minimal to no blood flow was detected in color-flow mode. Compression was facilitated using a solid gel pad attached to the transducer. Strain values were obtained from B-mode images of the gel pad and plotted versus study weeks. The <i>t</i> test comparisons were obtained to the baseline (week 0). Data from female and male pigs were plotted and analyzed separately for comparison. Gel pad strain increased with peak around week 4 and gradually decreased in both sexes. In male pigs, the increase in strain was statistically significant in weeks 2, 4, and 6 of all teeth regions and week 8 of PM4 and M1 regions. In female pigs, the increase in strain was significant in only week 4 of PM4. Higher strain required for stoppage of blood flow implies increased gingival blood flow with inflammation, which corresponds with previous studies. Considerably smaller changes in gel pad strain were noted from female pigs, indicating a smaller increase in gingival blood flow compared with males. This study demonstrated a possible application of intraoral ultrasonography for assessment of gingival inflammation.</p>","PeriodicalId":94075,"journal":{"name":"Journal of dental research","volume":" ","pages":"220345241286807"},"PeriodicalIF":0.0000,"publicationDate":"2024-11-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Ultrasonographic Evaluation of Vascular Response to Mechanical Compression during Induced Gingival Inflammation.\",\"authors\":\"J Woo, O Kripfgans, I-C Wang, A Samal, A R Betancourt, J C Fenno, H-L Chan\",\"doi\":\"10.1177/00220345241286807\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The aim of this study was to evaluate the gingival vascular response to mechanical compression during inflammation using ultrasonography. Four female and 4 male Sinclair mini pigs 18 mo of age were included in the study. Pathogenic bacteria-impregnated silk ligatures were placed around the third premolars (PM3), fourth premolars (PM4), and first molars (M1). Ligatures were placed per quadrant at 2-wk intervals in random order. Ultrasonographic study was performed at 2-wk intervals following baseline until the 10th week. Brightness mode (B-mode) images and color flow cine loops were captured at 2 different conditions: 1 with only coupling gel between the ultrasound transducer and the mucosal surface and 1 with the transducer compressing the mucosal surface. The compression was visually adjusted until minimal to no blood flow was detected in color-flow mode. Compression was facilitated using a solid gel pad attached to the transducer. Strain values were obtained from B-mode images of the gel pad and plotted versus study weeks. The <i>t</i> test comparisons were obtained to the baseline (week 0). Data from female and male pigs were plotted and analyzed separately for comparison. Gel pad strain increased with peak around week 4 and gradually decreased in both sexes. In male pigs, the increase in strain was statistically significant in weeks 2, 4, and 6 of all teeth regions and week 8 of PM4 and M1 regions. In female pigs, the increase in strain was significant in only week 4 of PM4. Higher strain required for stoppage of blood flow implies increased gingival blood flow with inflammation, which corresponds with previous studies. Considerably smaller changes in gel pad strain were noted from female pigs, indicating a smaller increase in gingival blood flow compared with males. This study demonstrated a possible application of intraoral ultrasonography for assessment of gingival inflammation.</p>\",\"PeriodicalId\":94075,\"journal\":{\"name\":\"Journal of dental research\",\"volume\":\" \",\"pages\":\"220345241286807\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-11-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of dental research\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1177/00220345241286807\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of dental research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/00220345241286807","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本研究的目的是利用超声波成像技术评估牙龈血管在炎症期间对机械压迫的反应。研究对象包括 4 头 18 月龄的雌性辛克莱迷你猪和 4 头雄性辛克莱迷你猪。在第三前臼齿(PM3)、第四前臼齿(PM4)和第一臼齿(M1)周围放置浸有病原菌的丝线结扎。每个象限的结扎间隔为 2 周,顺序随机。从基线开始到第 10 周,每隔 2 周进行一次超声波检查。在两种不同的条件下采集亮度模式(B 型)图像和彩色血流显像环:一种情况是在超声换能器和粘膜表面之间仅使用耦合凝胶,另一种情况是换能器压迫粘膜表面。在彩色血流模式下,通过目测调整压迫程度,直到检测到最小血流或无血流。使用连接到换能器上的固体凝胶垫有助于压迫。从凝胶垫的 B 型图像中获得应变值,并绘制出与研究周数的对比图。与基线(第 0 周)进行 t 检验比较。雌性猪和雄性猪的数据分别绘制和分析,以进行比较。雌猪和雄猪的凝胶垫应变都在第 4 周左右达到峰值并逐渐降低。公猪在第 2、4 和 6 周所有牙齿区域以及第 8 周 PM4 和 M1 区域的应变增加具有统计学意义。在雌猪中,应变的增加仅在 PM4 的第 4 周显著。血流停止所需的应变较高,这意味着牙龈血流随炎症而增加,这与之前的研究相符。雌性猪凝胶垫应变的变化要小得多,这表明与雄性猪相比,牙龈血流的增加较小。这项研究证明了口腔内超声波成像在牙龈炎症评估中的应用可能性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Ultrasonographic Evaluation of Vascular Response to Mechanical Compression during Induced Gingival Inflammation.

The aim of this study was to evaluate the gingival vascular response to mechanical compression during inflammation using ultrasonography. Four female and 4 male Sinclair mini pigs 18 mo of age were included in the study. Pathogenic bacteria-impregnated silk ligatures were placed around the third premolars (PM3), fourth premolars (PM4), and first molars (M1). Ligatures were placed per quadrant at 2-wk intervals in random order. Ultrasonographic study was performed at 2-wk intervals following baseline until the 10th week. Brightness mode (B-mode) images and color flow cine loops were captured at 2 different conditions: 1 with only coupling gel between the ultrasound transducer and the mucosal surface and 1 with the transducer compressing the mucosal surface. The compression was visually adjusted until minimal to no blood flow was detected in color-flow mode. Compression was facilitated using a solid gel pad attached to the transducer. Strain values were obtained from B-mode images of the gel pad and plotted versus study weeks. The t test comparisons were obtained to the baseline (week 0). Data from female and male pigs were plotted and analyzed separately for comparison. Gel pad strain increased with peak around week 4 and gradually decreased in both sexes. In male pigs, the increase in strain was statistically significant in weeks 2, 4, and 6 of all teeth regions and week 8 of PM4 and M1 regions. In female pigs, the increase in strain was significant in only week 4 of PM4. Higher strain required for stoppage of blood flow implies increased gingival blood flow with inflammation, which corresponds with previous studies. Considerably smaller changes in gel pad strain were noted from female pigs, indicating a smaller increase in gingival blood flow compared with males. This study demonstrated a possible application of intraoral ultrasonography for assessment of gingival inflammation.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信