Paula Perlea, Cosmin Stefanescu, Alexandru Eugen Petre
{"title":"基于印模法的数字制作氧化锆和金属桩核的临床验收。","authors":"Paula Perlea, Cosmin Stefanescu, Alexandru Eugen Petre","doi":"10.3390/clinpract14060199","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The existing literature predominantly examines post and core assessments post-cementation, neglecting the critical pre-cementation phase. Research on the clinical acceptance of dental posts received from dental laboratories before cementation is notably lacking. This study investigates the percentage of zirconia and metal dental posts that are deemed suitable for cementation by clinicians, among the total received from the dental laboratory. Additionally, it aims to examine whether this percentage varies based on the type of impression made by the clinician: digital impression versus conventional impression.</p><p><strong>Methods: </strong>This article introduces the application of computer-aided design-computer-aided manufacturing (CAD-CAM) technology for manufacturing customized zirconia and Cobalt-Chromium (Co-Cr) post and cores. Intraoral scanning is employed to capture the canal anatomy. In contrast to the traditional casting process, a three-dimensional (3D) metal printer machine is utilized to 3D print the metal post and core from Co-Cr, resulting in enhanced toughness and superior adaptability to the canal. Two null hypotheses were formulated, investigating the clinical acceptance of zirconia and metal posts obtained through traditional versus digital impressions.</p><p><strong>Results: </strong>Among 577 post and cores, 95% of metal posts from both impression methods received clinical approval. However, for zirconia posts, a significantly higher acceptance rate (95% versus 88%) was observed for those from traditional impressions. The Chi-squared test yielded a <i>p</i>-value < 0.05, underscoring the clinical superiority of conventionally obtained zirconia posts and supporting the null hypothesis for metal posts.</p><p><strong>Conclusions: </strong>A significantly higher acceptance rate is apparent among zirconia post and cores manufactured through conventional impressions, in contrast to zirconia post and cores produced via digital impressions. No statistically significant difference was identified between metal post and cores obtained through digital impressions and those acquired through conventional impressions.</p>","PeriodicalId":45306,"journal":{"name":"Clinics and Practice","volume":"14 6","pages":"2533-2541"},"PeriodicalIF":1.7000,"publicationDate":"2024-11-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Clinical Acceptance of Digitally Produced Zirconia and Metal Post and Cores, Based on the Impression Method.\",\"authors\":\"Paula Perlea, Cosmin Stefanescu, Alexandru Eugen Petre\",\"doi\":\"10.3390/clinpract14060199\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>The existing literature predominantly examines post and core assessments post-cementation, neglecting the critical pre-cementation phase. Research on the clinical acceptance of dental posts received from dental laboratories before cementation is notably lacking. This study investigates the percentage of zirconia and metal dental posts that are deemed suitable for cementation by clinicians, among the total received from the dental laboratory. Additionally, it aims to examine whether this percentage varies based on the type of impression made by the clinician: digital impression versus conventional impression.</p><p><strong>Methods: </strong>This article introduces the application of computer-aided design-computer-aided manufacturing (CAD-CAM) technology for manufacturing customized zirconia and Cobalt-Chromium (Co-Cr) post and cores. Intraoral scanning is employed to capture the canal anatomy. In contrast to the traditional casting process, a three-dimensional (3D) metal printer machine is utilized to 3D print the metal post and core from Co-Cr, resulting in enhanced toughness and superior adaptability to the canal. Two null hypotheses were formulated, investigating the clinical acceptance of zirconia and metal posts obtained through traditional versus digital impressions.</p><p><strong>Results: </strong>Among 577 post and cores, 95% of metal posts from both impression methods received clinical approval. However, for zirconia posts, a significantly higher acceptance rate (95% versus 88%) was observed for those from traditional impressions. The Chi-squared test yielded a <i>p</i>-value < 0.05, underscoring the clinical superiority of conventionally obtained zirconia posts and supporting the null hypothesis for metal posts.</p><p><strong>Conclusions: </strong>A significantly higher acceptance rate is apparent among zirconia post and cores manufactured through conventional impressions, in contrast to zirconia post and cores produced via digital impressions. No statistically significant difference was identified between metal post and cores obtained through digital impressions and those acquired through conventional impressions.</p>\",\"PeriodicalId\":45306,\"journal\":{\"name\":\"Clinics and Practice\",\"volume\":\"14 6\",\"pages\":\"2533-2541\"},\"PeriodicalIF\":1.7000,\"publicationDate\":\"2024-11-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Clinics and Practice\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3390/clinpract14060199\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"MEDICINE, GENERAL & INTERNAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinics and Practice","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/clinpract14060199","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MEDICINE, GENERAL & INTERNAL","Score":null,"Total":0}
引用次数: 0

摘要

背景:现有文献主要研究牙柱和牙核固位后的评估,而忽略了关键的固位前阶段。尤其缺乏对牙科技工室在粘接前收到的牙科柱的临床接受程度的研究。本研究调查了临床医生认为适合粘接的氧化锆和金属牙科柱在从牙科技工室收到的总数中所占的百分比。此外,该研究还旨在探讨这一比例是否会因临床医生制作的印模类型(数字印模与传统印模)而有所不同:本文介绍了计算机辅助设计-计算机辅助制造(CAD-CAM)技术在制造定制氧化锆和钴铬(Co-Cr)桩核方面的应用。口内扫描用于捕捉牙槽解剖结构。与传统的铸造工艺不同,该技术利用三维(3D)金属打印机3D打印出钴铬合金的金属基桩和桩核,从而增强了韧性并提高了对牙槽骨的适应性。我们提出了两个零假设,研究通过传统印模和数字印模获得的氧化锆和金属支架的临床接受度:结果:在 577 个桩和桩核中,95% 的金属桩在两种印模方法中都获得了临床认可。然而,就氧化锆桩而言,传统印模的接受率明显更高(95% 对 88%)。Chi-squared检验得出的P值小于0.05,强调了传统方法获得的氧化锆基台在临床上的优越性,并支持对金属基台的零假设:通过传统印模制作的氧化锆桩和桩核的接受率明显高于通过数字印模制作的氧化锆桩和桩核。通过数字印模获得的金属支架和核心与通过传统印模获得的金属支架和核心在统计学上没有明显差异。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Clinical Acceptance of Digitally Produced Zirconia and Metal Post and Cores, Based on the Impression Method.

Background: The existing literature predominantly examines post and core assessments post-cementation, neglecting the critical pre-cementation phase. Research on the clinical acceptance of dental posts received from dental laboratories before cementation is notably lacking. This study investigates the percentage of zirconia and metal dental posts that are deemed suitable for cementation by clinicians, among the total received from the dental laboratory. Additionally, it aims to examine whether this percentage varies based on the type of impression made by the clinician: digital impression versus conventional impression.

Methods: This article introduces the application of computer-aided design-computer-aided manufacturing (CAD-CAM) technology for manufacturing customized zirconia and Cobalt-Chromium (Co-Cr) post and cores. Intraoral scanning is employed to capture the canal anatomy. In contrast to the traditional casting process, a three-dimensional (3D) metal printer machine is utilized to 3D print the metal post and core from Co-Cr, resulting in enhanced toughness and superior adaptability to the canal. Two null hypotheses were formulated, investigating the clinical acceptance of zirconia and metal posts obtained through traditional versus digital impressions.

Results: Among 577 post and cores, 95% of metal posts from both impression methods received clinical approval. However, for zirconia posts, a significantly higher acceptance rate (95% versus 88%) was observed for those from traditional impressions. The Chi-squared test yielded a p-value < 0.05, underscoring the clinical superiority of conventionally obtained zirconia posts and supporting the null hypothesis for metal posts.

Conclusions: A significantly higher acceptance rate is apparent among zirconia post and cores manufactured through conventional impressions, in contrast to zirconia post and cores produced via digital impressions. No statistically significant difference was identified between metal post and cores obtained through digital impressions and those acquired through conventional impressions.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Clinics and Practice
Clinics and Practice MEDICINE, GENERAL & INTERNAL-
CiteScore
2.60
自引率
4.30%
发文量
91
审稿时长
10 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信